1502: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(3 intermediate revisions by 2 users not shown)
Line 3: Line 3:
|model=1502
|model=1502
|class=Reflectometer
|class=Reflectometer
|series=
|series=1500
|summary=Time Domain Reflectometer
|summary=Time Domain Reflectometer
|image=Tek1502-front.JPG
|image=Tek1502-front.JPG
|caption=Tektronix 1502 Time Domain Reflectometer (CRT version)
|caption=Tektronix 1502 Time Domain Reflectometer
|introduced=1975
|introduced=1975
|discontinued=(?)
|discontinued=(?)
|designers=Hans Geerling
|designers=Hans Geerling
|manuals=
|manuals=
'''1502'''
* [[Media:070-1790-00.pdf|Tektronix 1502 Operators Manual]]
* [[Media:070-1790-00.pdf|Tektronix 1502 Operators Manual]]
* [[Media:070-1792-01.pdf|Tektronix 1502 Service Manual -01]]
* [[Media:070-1792-01.pdf|Tektronix 1502 Service Manual -01]]
Line 21: Line 20:
* [[Media:Tek_1502_Wizard_Workshop.pdf|Tektronix 1502 Wizard Workshop Articles]]
* [[Media:Tek_1502_Wizard_Workshop.pdf|Tektronix 1502 Wizard Workshop Articles]]
* [[Media:Tek_1502_mods.pdf|Tektronix 1502 Modifications]]
* [[Media:Tek_1502_mods.pdf|Tektronix 1502 Modifications]]
'''1502B'''
* [[Media:070-6266-01.pdf|Tektronix 1502B Operator Manual]]
* [[Media:070-6267-04.pdf|Tektronix 1502B Service Manual]]
'''1502C'''
* [[Media:070-7169-05.pdf|Tektronix 1502C User Manual]]
* [[Media:070-7168-04.pdf|Tektronix 1502C Service Manual]]


'''Other'''
'''Other'''
* [[Media:Tektronix_Y-T_chart_recorder.pdf|Tektronix Chart Recorder User/Service Manual]]
* [[Media:Tektronix_Y-T_chart_recorder.pdf|Tektronix Chart Recorder User/Service Manual]]
* [[Media:070-2178-00.pdf|Watertight Sealing Procedures for 1502/1503 TDRs]]
* [[Media:070-2178-00.pdf|Watertight Sealing Procedures for 1502/1503 TDRs]]
* [[Media:Optimize falltime and aberrations 1502 no ocr.pdf|Guide to Optimizing Falltime and Aberrations in the 1502]] (needs OCR)
* [[Media:Optimize falltime and aberrations 1502.pdf|Guide to Optimizing Falltime and Aberrations in the 1502]]


:''Note that the manuals for the 1502B and 1503C are still available from Tektronix.''
}}
}}
The '''Tektronix 1502''' is a series of Time Domain Reflectometers which replaced the [[1501]] in 1975.  The 1502 is for high resolution, sister model [[1503]] for long range.
The '''Tektronix 1502''' is a series of Time Domain Reflectometers which replaced the [[1501]] in 1975.  The 1502 is for high resolution, sister model [[1503]] for long range.
Line 48: Line 37:


==Internals and version differences==
==Internals and version differences==
The first version used a CRT and is an almost completely analog design except for some discrete digital logic used to pre-fire and fire the [[tunnel diodes|tunnel diode]] pulser.   
The 1502 used a CRT and is an almost completely analog design except for some discrete digital logic used to pre-fire and fire the [[tunnel diodes|tunnel diode]] pulser.   
The later models (1502B/C) used a liquid-crystal display and a Z80 microprocessor.   
The later models ([[1502B]], [[1502C]]) used a liquid-crystal display and a Z80 microprocessor.   


The other major difference between versions is the line charging method.
The other major difference between versions is the line charging method.
Line 56: Line 45:


==Repair issues==
==Repair issues==
→ see [[1502/Repairs]]
→ see [[1502/Repairs]]
 
==Replacement==
MOHR Test and Measurement manufactures a direct replacement to the 1502B and 1502C using an updated version of the same pulser/sampler. 
Any procedures or recorded waveforms are repeatable using the MOHR TDR.''[http://www.mohr-engineering.com/ct100 CT100B TDR Cable Analyzer]''.


==Links==
==Links==
{{Documents|Link=1502}}
{{Documents|Link=1502}}
{{PatentLinks|1502}}


==Prices==
==Prices==
1979: $3,750 (~$14,700 in 2022 Dollars)
1979: $3,750 (~$16,200 in 2024 dollars)


According to an [[Media:Tek Schottky Diodes Memo rot.pdf|internal memo]], in 1979 annual sales were estimated at 543 units.
According to an [[Media:Tek Schottky Diodes Memo rot.pdf|internal memo]], in 1979 annual sales were estimated at 543 units.


==Pictures==
==Pictures==
'''1502'''
<gallery>
<gallery>
Tek1502-top.JPG|Top boards of the 1502
Tek1502-top.JPG|Top boards of the 1502
Line 85: Line 70:
1502_Front_metric_version.jpg|Tek 1502 Metric Version (Option 5)
1502_Front_metric_version.jpg|Tek 1502 Metric Version (Option 5)
</gallery>
</gallery>
 
'''1502B'''
==Components==
<gallery>
{{Parts|1502}}
Tek 1502b 1.jpg|1502B
Tek 1502b 2.jpg|1502B
Tek 1502b 3.jpg|1502B
Tek 1502b 4.jpg|1502B
</gallery>
 


[[Category:Time-domain reflectometers]]
[[Category:Time-domain reflectometers]]

Latest revision as of 03:52, 24 September 2024

Manuals – Specifications – Links – Pictures

The Tektronix 1502 is a series of Time Domain Reflectometers which replaced the 1501 in 1975. The 1502 is for high resolution, sister model 1503 for long range.

They are commonly used to test coaxial cables, although they have many other uses. The US military was a major purchaser, therefore most of the first series (the 1502, no letter) will be found surplus with some sort of US military property ID tag and an NSN sticker.

Hans Geerling did most of the circuit design on the 1502.

Key Specifications

  • please add

Internals and version differences

The 1502 used a CRT and is an almost completely analog design except for some discrete digital logic used to pre-fire and fire the tunnel diode pulser. The later models (1502B, 1502C) used a liquid-crystal display and a Z80 microprocessor.

The other major difference between versions is the line charging method. The 1502 uses a fast (36 ps) tunnel diode pulser, the later models used a half sine wave to charge the line. The TD pulser, with its Dirac delta edge, gives much better short range sensitivity, although it is much easier to destroy.

Repair issues

→ see 1502/Repairs

Links

Documents Referencing 1502

Document Class Title Authors Year Links
Tekscope 1975 V7 N2.pdf Article Two Weatherproof TDR Cable Testers for Field Use Ivan Ivanov 1975
Tekscope 1975 V7 N3.pdf Article New Products 1975
TekWeek (partial) October 10, 1975.pdf Article Spectrum analyzers require high technology Thor Hallen Dave Friedley 1975

Prices

1979: $3,750 (~$16,200 in 2024 dollars)

According to an internal memo, in 1979 annual sales were estimated at 543 units.

Pictures

Components

Some Parts Used in the 1502

Part Part Number(s) Class Description Used in
152-0335-01 152-0335-01 Discrete component 150 ps step recovery diode 1502 S-2 S-4 S-6
154-0667-00 154-0667-00 154-0667-01 154-0667-02 154-0667-03 CRT CRT 1502 1503 305 326
2N3958 151-1054-00 151-1054-01 151-1054-02 Discrete component dual n-channel JFET FG503 MR501 M3 PG505 SC501 SC502 SC503 SG502 1450 1501 1502 1503 221 5A23N 5CT1N 577 603 603A 604 604A 605 606 606A 606B 607 607A 620 624 7CT1N 7D15 7D20 851
SMTD995 152-0140-01 Discrete component 10 mA, 8 pF tunnel diode 1S1 1S2 1502 21A 22A 3T5 3T6 475 475A 475M 544 R544 546 RM546 547 RM547 556 R556 581A 585A RM585 7B52 7B53N 7B70 7B71 7D10 7D11 7T11 7T11A R7912 S-51 S-52 TU-5 067-0572-00 067-0572-01 067-0681-00