The '''Tektronix 2430''' is a portable dual-channel digital scope from the [[2000-series scopes|2000-series]]. There is also a 2430A.
The '''Tektronix 2430A''' is a portable dual-channel digital scope from the [[2000-series scopes|2000-series]], an updated version of the [[2430]].
<blockquote>
<blockquote>
'''WARNING: '''Operation of the 2440, 2432, 2432A, 2430, and 2430A: A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
'''WARNING: '''Operation of the 2440, 2432, 2432A, 2430, and 2430A: A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.

Revision as of 03:40, 30 July 2024

Tektronix 2430A
150 MHz, 100 MS/s portable digital scope
Tektronix 2430

Produced from 1988 to 1994

Manuals
ROM Images
File Pos. Checksum
160-4398-04 U670 b8d76ded
160-4399-04 U680 f3f1f472
160-4400-04 U682 d2cc2120
160-4401-04 U690 943e4695
160-4402-04 U692 70cba0e9
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2430A is a portable dual-channel digital scope from the 2000-series, an updated version of the 2430.

WARNING: Operation of the 2440, 2432, 2432A, 2430, and 2430A: A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.

Key Specifications

Bandwidth 150 MHz (Limit: 20, 50, Full)
Rise time 2.33 ns (Repeat on, 16×averaging)
Sampling rate 100 MS/s
Sampling type Real time: 500 ns/Div and slower, Equivalent time 200 ns/Div and faster
Single event bandwidth 40 MHz (2430A)
Glitch capture 2 ns
Deflection 2 mV/div to 5 V/div in 1-2-5 sequence
Resolution 8 bit
Record length 1024 samples
Input impedance 1 MΩ // 15 pF or 50 Ω
Sweep speeds 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)
Acquisition modes Normal, Envelope (glitch capture), Average
Display modes CH1, CH2, invert, add, multiply, X-Y
Cursors Volts, Time, Volts At Time, 1/Time, Slope
Functions A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more
Interface GPIB
Probes Two passive P6133 150 MHz ×10 voltage probes, 1.3 m

Features

  • Printer/plotter output
  • On-screen help
  • GPIB
  • Autoprobe Function With P6137 Probe
  • 150 MHz X-Y bandwidth at probe tip
  • Automatic measurements
  • extensive triggering capabilities

Options

Links

Documents Referencing 2430A

(no results)

Pictures

Components

Some Parts Used in the 2430A

Part Part Number(s) Class Description Used in
154-0850-01 154-0850-00 154-0850-01 CRT CRT 2424L 2430 2430A 2431L 2432 2439 2440 2445 2465 2465A 2465B
155-0238-00 155-0238-00 Hybrid integrated circuit preamplifier 11302A 2424L 2430 2430A 2432 2445 2465 2466 2467
155-0239-00 155-0239-00 155-0239-01 155-0239-02 Hybrid integrated circuit trigger 2424L 2430 2430A 2432 2445 2465 2467 2400-series scopes 11201 11401 11402
230-0001-50 230-0001-50 Hybrid integrated circuit phase clock array 2424L 2430 2430A 2432
230-0002-50 230-0002-50 Hybrid integrated circuit trigger logic array 2424L 2430 2430A 2432