549: Difference between revisions

510 bytes added ,  16 April 2019
no edit summary
No edit summary
No edit summary
Line 96: Line 96:


The 549 uses a [[120-0423-00]] HV transformer.
The 549 uses a [[120-0423-00]] HV transformer.
==Repair issues==
549 from  Portland factory  uses ONE black paper-capacitor  from Areovox. Capacitor with 0.5 µF 600 V rating is using in horizontal amplifier.  Result: compressing  trace on right side. 
Solution:  Replacing him with ordinary 0.47 µF 630V(and above) capacitor.  Their location is upper chassis, middle.
Ironcally, dutch made 549 have never this problem.
<gallery>
549badtrace.jpg | compressing trace on right side
549-areovox.png | Result of bad ROM by verification-check.
</gallery>


==Links==
==Links==
1,081

edits