067-0587-01: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
(removed info for 067-0587-00 and harmonized specs following 067-0587-02 format)
Line 15: Line 15:
It provides a uniform step calibrated deflection factor, a fast risetime
It provides a uniform step calibrated deflection factor, a fast risetime
step response function and a common-mode input test for both the
step response function and a common-mode input test for both the
vertical and trigger systems.  It is the predecessor of the [[067-0587-02]].
vertical and trigger systems.  It is the successor of the [[067-0587-00]] and the predecessor of the [[067-0587-02]].


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Rise time | 300 ps}}
{{SpecGroup | GAIN mode }}
{{Spec | Bandwidth | 500 MHz (067-0587-01) / 250 MHz (067-0587-00) }}
{{Spec | Staircase accuracy | ± 0.3% with no error in mainframe ±50 V supply}}
{{SpecGroup |  STEP RESP mode }}
{{Spec | Amplitude | >8 Div }}
{{Spec | Rise time | < 300 ps}}
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, within 20 % of rate selected}}
{{Spec | Pretrig Out | unspecified }}
{{SpecGroup |  FREQ RESP mode }}
{{Spec | Input impedance | 50 Ω }}
{{Spec | Input range    | 0.5 to 1 V<sub>p-p</sub> }}
{{Spec | Flatness | leveled from 3 MHz to 500 GHz }}
{{EndSpecs}}
{{EndSpecs}}


Line 42: Line 51:
067-0587-01 1.jpg
067-0587-01 1.jpg
067-0587-01 2.jpg
067-0587-01 2.jpg
Tek 067-0587-00.jpg|067-0587-00
Tek 067-0587-01 trace.jpg
Tek 067-0587-01 trace.jpg
Tek 067-0587-01 2.jpg
Tek 067-0587-01 2.jpg

Revision as of 11:15, 13 June 2022

Tektronix 067-0587-01
calibration fixture
067-0587-01

Compatible with 7000-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0587-01 Calibration Fixture is designed to standardize the horizontal and vertical deflection factors of 7000 series mainframes. It provides a uniform step calibrated deflection factor, a fast risetime step response function and a common-mode input test for both the vertical and trigger systems. It is the successor of the 067-0587-00 and the predecessor of the 067-0587-02.

Key Specifications

     — GAIN mode
Staircase accuracy ± 0.3% with no error in mainframe ±50 V supply
     — STEP RESP mode
Amplitude >8 Div
Rise time < 300 ps
Repetition rate 10 Hz to 1 MHz in decade steps, within 20 % of rate selected
Pretrig Out unspecified
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness leveled from 3 MHz to 500 GHz

Internals

It uses one custom Tektronix IC, the 155-0078-00. The manual says it is a high frequency push-pull amplifier.

It uses one tunnel diode, the 152-0177-00, a 10 mA, 4 pF diode in a DO-17 package. It also uses 12 Tektronix custom Schottky diodes, part 152-0442-00 (speced as matched pairs) in the tunnel diode pulse shaper and in the CW peak-to-peak detector. The service manual calls them "disconnect diodes", physically they look like snap-off diodes found in other Tektronix fast risetime pulsers. Note that there is a typo in the service manual for CR80, CR84, and CR85 in the peak-to-peak detector.

Links

Pictures

Custom ICs used in the 067-0587-01

Page Model Part nos Description Designers Used in
155-0078-00 M084 155-0078-xx 155-0273-00 155-0274-00 broadband amplifier John Addis 464 465 466 468 475 475A 475M 485 7834 7844 7854 7904 R7903 R7912 7912AD 7912HB 7104 7A16A 7A16P 7A24 7A26 7A42 067-0587-01 067-0680-00 AM503 PG502 PG508 DC510 DC5010 FG5010