Line 88: Line 88:
* [http://ik1zyw.blogspot.com/2007/09/tektronix-7a13-broken-relays.html Tek 7A13 broken relays @ IK1ZYW Labs]
* [http://ik1zyw.blogspot.com/2007/09/tektronix-7a13-broken-relays.html Tek 7A13 broken relays @ IK1ZYW Labs]
* [https://groups.io/g/TekScopes/message/119028 "... used a function generator to actuate it for a few hours which restored proper operation."]
* [https://groups.io/g/TekScopes/message/119028 "... used a function generator to actuate it for a few hours which restored proper operation."]
* [[Media:Tektronix_Common_Design_Parts_Electro-Mechanical_Catalog_4_jan_1989_ocr.pdf|1989 Electro-Mechanical Catalog]] (OCR)


==Pictures==
==Pictures==
<gallery>
<gallery>
148-0034-03.jpg | 148-0034-03 in [[7A11]]
148-0034-03.jpg | 148-0034-03 in [[7A11]]

Revision as of 23:44, 14 July 2022

In the 1970s, Tek produced their own miniature relays in-house that were used in some 7000-series plug-ins such as the 7A11, 7A12, 7A13, 7A14, and other equipment. These relays have a tendency to fail and working ones have become very rare. Some of these relays have symmetrical socket layouts so that they can be installed in both possible 180° rotated positions.

Interestingly, Tek appears to have manufactured replacements based on commercial relays in TO-5 metal can cases soldered to small carrier boards with pins matching the Tek sockets.

Possible repair strategies include "micro-surgery" (Ref.1), installing modern miniature gold-contact relays on top of the cut-off base or, if energizing the coil mechanically operates the relay, using a signal source to cycle the relay for a period of time.

Relays of the 148-0034-00 family have contacts with 100mil (2.54 mm) pitch; the housings are 16.0 x 8.3 x 15 mm (width x depths x height).

Tek P/N Contacts Coil Used in Replacement Note
108-0599-00 SPST (reed) 7T11: A3K31,A3K32,A3K70,A3K71,A3K80
148-0034-00 DPDT 15 V 600 Ω

7A11: K401, K403, K405, K407, K411, K413, K415, K417, K431
7A13: K47, K48, K480, K490
7A14: K50, K62, K330
7B70/7B71: K6, K44, K48, K138, K780
7503: K521, K525
7904(A) Opt. 2: K802, K805, K812, K815

AXICOM V23079-D2003-B301 (Ref. 2)
Omron G6N, G6S
148-0034-01 DPDT 15 V 600 Ω

7A12: K7, K12, K15, K18
485: K879, K1242

Same pinout as 148-0034-00 but longer leads bent outwards.
148-0034-02 DPDT 15 V 600 Ω 7A12: K7 for B020000 up Same pinout as 148-0034-00 but longer leads bent outwards.
148-0034-03 DPDT 15 V 600 Ω 7A11 B100000+: K401, K403, K405, K407, K411, K413, K415, K417, K431 AXICOM V23079-D2003-B301 (Ref. 2)
148-0035-00 SPDT 15 V 600 Ω 7A13: K60, K61
7A14: K51, K52, K53, K155, K160, K180, K235, K280
7B70, 7B71: K3
Same pinout and coil data as 148-0050-00.
148-0043-00 DPDT 24 V 1325 Ω
148-0043-01 DPDT 24 V 1325 Ω
148-0044-00 DPDT 12 V 425 Ω
148-0050-00 SPDT 15 V 600 Ω 7A13: K10, K30 7A13 manual erroneously calls them 12V DC relays. Print on relay identifies them as polarized, but they are not.
148-0054-00 SPDT+SPST 15 V 600 Ω 7A13: K7, K27
148-0055-00 SPDT+SPST 15 V 600 Ω 7A13: K6, K26
148-0058-00 4 V 130 Ω 7A11 Probe: K55, K59
148-0059-00 DPDT 9.5 V 115 Ω
148-0063-00 DPDT 15 V 600 Ω 7A12: K5 Internally connected. Labled "Alt throw relay" in 7A12 manual.
148-0076-00 SPST (reed) 7L12: K1470
148-0080-00 DPDT 5 V at 65 Ω
148-0087-00 SPDT 90 mW 7L12: K300, K353, K356, K1200
148-0088-00 DPDT 15 V 1 kΩ

7L12: K281, K354, K355, K357, K1130, K1400, K1450
L1 K108, K118, K128, K138
L2 K308, K318, K328, K338

Same pinout as 148-0034-00. 7L12 manual claims "120 mW", but print on relay (and measurement) says 15V 1000 Ω which is 225 mW.
148-0107 DPDT 18 V 880 Ω TO5 replacement for 148-0088-00 Based on Hi-G MAW-169 7815 / Teledyne 412-6841, found in L1. The last two digits of the Tek part number are missing. Coil labeled 18V dc, 880 Ω
148-0107-03 SPDT TO5 replacement
148-0107-04 DPDT TO5 replacement for 148-0054-00 (7A13: K7, K27)
148-0140-00 Actuator 2400 series

to be expanded


Links

Pictures

Other custom relays in Tek equipment

  • 7A29 input protection relay