7B15: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 10: Line 10:
|designers=Art Metz;Bruce Hofer;Val Garuts
|designers=Art Metz;Bruce Hofer;Val Garuts
|manuals=
|manuals=
* [[Media:070-2318-00.pdf|7B15 Instruction Manual]] (PDF, OCR)  
* [[Media:070-2319-00.pdf|7B15 Operator's Manual]] (OCR)
* [[Media:070-2319-00.pdf|7B15 Operators Manual]] (PDF, OCR)
* [[Media:070-2318-00.pdf|7B15 Instruction Manual]] (OCR)  
}}
}}
The '''Tektronix 7B15''' is a 1 GHz delaying time base for [[7000-series scopes]], in particular, the 1 GHz [[7104]] (typically used with [[7A29]] vertical amplifiers and a [[7B10]] delayed time base).
The '''Tektronix 7B15''' is a 1 GHz delaying time base for [[7000-series scopes]], in particular, the 1 GHz [[7104]] (typically used with [[7A29]] vertical amplifiers and a [[7B10]] delayed time base).
Line 29: Line 29:


==Internals==
==Internals==
A ramp generator is started when the trigger signal arrives.  The delayed sweep is started when a  
A ramp generator is started when the trigger signal arrives.   
comparator detects that the ramp has reached a control voltage, set by the front panel knobs.
The delayed sweep is started when a comparator detects that the ramp has reached a control voltage, set by the front panel knobs.
The control voltage is therefore proportional to the amount of delay and is measured using a  
The control voltage is therefore proportional to the amount of delay and is measured using a [[155-0185-00]] 4-digit DVM circuit,  
[[155-0185-00]] 4-digit DVM circuit, then displayed on the [[7000 series readout system|oscilloscope readout]].
then displayed on the [[7000 series readout system|oscilloscope readout]].
The display, scaled in seconds, provides the operator with a precise readout of the delay.
The display, scaled in seconds, provides the operator with a precise readout of the delay.


Line 38: Line 38:


The 7B15 uses the +50 V supply provided by the mainframe.
The 7B15 uses the +50 V supply provided by the mainframe.
==Pictures==
==Pictures==



Revision as of 11:30, 9 March 2022

Tektronix 7B15
1 GHz delaying timebase
7B15

Compatible with 7000-series scopes

Produced from 1978 to 1990

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 7B15 is a 1 GHz delaying time base for 7000-series scopes, in particular, the 1 GHz 7104 (typically used with 7A29 vertical amplifiers and a 7B10 delayed time base).

The 7B15 provides digital readout of delay and delta times. In effect, the 7B15/7B10 pair are speed-improved versions of the 7B85/7B80.

Key Specifications

Sweep 200 ms/Div to 2 ns/Div in 1−2−5 sequence, ×10 magnifier down to 200 ps/Div, variable to ×2.5
Triggering to 1 GHz
Jitter less than 30 ps at 1 GHz
Features
  • Digital read-out of delay and delta times
  • Variable Trigger Holdoff
  • HF Sync mode

Internals

A ramp generator is started when the trigger signal arrives. The delayed sweep is started when a comparator detects that the ramp has reached a control voltage, set by the front panel knobs. The control voltage is therefore proportional to the amount of delay and is measured using a 155-0185-00 4-digit DVM circuit, then displayed on the oscilloscope readout. The display, scaled in seconds, provides the operator with a precise readout of the delay.

Other custom Tek ICs used: 155-0150-00 trigger detector, 155-0160-00 trigger amplifier.

The 7B15 uses the +50 V supply provided by the mainframe.

Pictures

Custom ICs used in the 7B15

Page Model Part nos Description Designers Used in
155-0049-00 M079G 155-0049-00 155-0049-01 155-0049-02 sweep control with lockout Bill DeVey 335 464 465 466 475 475A 475M 485 5B31 5B40 5B52 5B42 5B44 7B53A 7B80 7B85 7B87 7B92A 7B90P 7B10 7B15 SC502 7B42N AN/USM-281C 067-0657-00
155-0149-00 155-0149-00 155-0149-00 sweep control 7B10 7B15
155-0150-00 H473 155-0150-00 trigger detector Art Metz 7904A 7104 7B10 7B15 7B92A SCD1000
155-0160-00 M136 155-0160-00 1.5 GHz trigger amplifier and source select Art Metz 7B10 7B15 067-0587-02 067-0587-10
155-0185-00 M187 155-0185-00 four-digit Counter, latch and D/A converter/DVM Don Larson 7B15 7B85 7B87