Passive Probes

From TekWiki
Revision as of 08:03, 15 October 2023 by Jaredcabot (talk | contribs) (Added P6112)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

This table is based on the Tek Probe Cross-Reference. Please expand.

Model Attenuation Length Input Loading Bandwidth Max. Voltage Compensation Range Readout
pin
R C
P2100 10× 1.5 m 5 ft 10 MΩ 14.5-18.5 pF 100 MHz 300 V 18-35 pF -
1 MΩ 80-110 pF 7 MHz 150 V n/a
P2200 10× ? ? 10 MΩ 13-17 pF 200 MHz 300 V 15-25 pF -
1 MΩ 80-110 pF 6 MHz 150 V n/a
P2220 10× 1.5 m 5 ft 10 MΩ 13-17 pF 200 MHz 300 V 15-25 pF -
1 MΩ 80-110 pF 6 MHz 150 V n/a
P3010 10× 2 m 10 MΩ 13.3 pF 100 MHz 300 VRMS 10-15 pF Y
P5050 10× 1.3 m 4 ft 10 MΩ 11.1 pF 500 MHz 400 V 16-22 pF Y
P5050B 10× 1.3 m 4 ft 10 MΩ 11 pF 500 MHz 300 VRMS 15-22 pF Y
P5100 100× 3.1 m 10 MΩ 2.75 pF 250 MHz 2.5 kV 7-30 pF Y
P5102 10× 2 m 5 MΩ 11.2 pF 100 MHz 1 kV 23-27 pF -
P5120 20× 3 m 5 MΩ 11.2 pF 200 MHz 1 kV 15-25 pF -
P5122 100× 1.2 m 4 ft 100 MΩ 4.6 pF 200 MHz 1 kV 10-25 pF -
P6000 10× 1 m 3.5 ft 10 MΩ 10 pF ? 1.2 kV 20-50 pF -
1.8 m 6 ft 10 pF ? 1.2 kV 20-50 pF -
2.7 m 9 ft 10 pF ? 1.2 kV 20-50 pF -
3.6 m 12 ft 10 pF ? 1.2 kV 20-50 pF -
P6003 10× 1 m 3.5 ft 10 MΩ 10 pF ? 1.2 kV 20-50 pF -
1.8 m 6 ft 10 pF ? 1.2 kV 20-50 pF -
2.7 m 9 ft 10 pF ? 1.2 kV 20-50 pF -
3.6 m 12 ft 10 pF ? 1.2 kV 20-50 pF -
P6006 10× 1 m 3.5 ft 10 MΩ 9.5 pF 70 MHz 1.2 kV 20-55 pF -
1.8 m 6 ft 11 pF 50 MHz
2.7 m 9 ft 13.5 pF 50 MHz
3.6 m 12 ft 15.5 pF 25 MHz
P6007 100× 1.8 m 6 ft 10 MΩ 2.2 pF 25 MHz 1.5 kV 15-55 pF -
P6008
010-0130-00
10× 1 m 3.5 ft 10 MΩ 7 pF 116 MHz 600 V 15 pF -
P6008
010-0130-01
10× 1.8 m 6 ft 10 MΩ 10-14 pF 100 MHz 600 V 15-55 pF -
P6009 100× 2.7 m 9 ft 10 MΩ 2.5 pF 120 MHz 1.5 kV 15-47 pF Y
P6009 Opt. 14 100× 2.7 m 9 ft 10 MΩ 2.5 pF 120 MHz 1.5 kV 15-47 pF -
P6010 10× 1 m 3.5 ft 10 MΩ 10 pF 150 MHz 500 V 14-21 pF -
P6011 1 m 3.5 ft 1 MΩ 48 pF 17 MHz 600 V n/a -
1.8 m 6 ft 1 MΩ 68 pF 10 MHz
2.7 m 9 ft 1 MΩ 95 pF 7 MHz
P6012 10× 1 m 3.5 ft 10 MΩ 11.5 pF 35 MHz 500 V 15-47 pF -
1.8 m 6 ft 10 MΩ 14.5 pF 30 MHz
2.7 m 9 ft 10 MΩ 17.5 pF 22 MHz
P6013A 1000× 3 m 10 ft 100 MΩ 3.0 pF 25 MHz 12 kV 20 pF -
P6015 1000× 3 m 10 ft 100 MΩ 3.0 pF 75 MHz 20 kV 12-47 pF -
P6023 10× 1 m 3.5 ft 8 MΩ 12 pF 50 MHz 1 kV 20-47 pF -
P6027
(UHF)
1 m 3.5 ft 1 MΩ 75 pF 21.9 MHz 600 V n/a -
1.8 m 6 ft 1 MΩ 93 pF 16.6 MHz
2.7 m 9 ft 1 MΩ 119 pF 12.5 MHz
3.6 m 12 ft 1 MΩ 143 pF 8.3 MHz
P6028
(BNC)
1 m 3.5 ft 1 MΩ 75 pF 21.9 MHz 600 V n/a -
1.8 m 6 ft 1 MΩ 93 pF 16.6 MHz
2.7 m 9 ft 1 MΩ 119 pF 12.5 MHz
3.6 m 12 ft 1 MΩ 143 pF 8.3 MHz
P6047 10× 1 m 3.5 ft 10 MΩ 10.3 pF 290 MHz 500 V 15-20 pF -
1.8 m 6 ft 10 MΩ 12 pF
P6048 10× 1.8 m 6 ft 1 kΩ 1 pF 140 MHz 20 VAC / 200 VDC 15-21 pF -
P6049 10× 1 m 3.5 ft 10 MΩ 13.5 pF 21 MHz 500 V 43-66 pF -
P6053B 10× 1.8 m 6 ft 10 MΩ 12.5 pF 200 MHz 500 V 15-24 pF Y
P6054 10× 1.8 m 6 ft 10 MΩ 12.5 pF 200 MHz 500 V 15-24 pF Y
P6055 10× 1 m 3.5 ft 1 MΩ 10 pF 60 MHz 500 V 12-47 pF Y
P6060 10× 0.9 m 3 ft 10 MΩ 7.5 pF 35 MHz 600 V 15-55 pF GND
1.8 m 6 ft 8.5 MΩ 25 pF
P6061 10× 1 m 3.5 ft 10 MΩ 9.5 pF 60 MHz 500 V 15-24 pF GND
1.8 m 6 ft 12 pF 60 MHz
2.7 m 9 ft 13.5 pF 60 MHz
P6062B 10× 1.8 m 6 ft 10 MΩ 14 pF 100 MHz 500 V 15-47 pF Y
1 MΩ 105 pF 7 MHz 500 V n/a
P6063B 10× 1.8 m 6 ft 10 MΩ 14 pF 200 MHz 500 V 15-24 pF Y
1 MΩ 105 pF 6 MHz 500 V n/a
P6065 10× 1.8 m 6 ft 10 MΩ 12.5 pF 100 MHz 500 V 20-24 pF Y
P6075 10× 1.8 m 6 ft 10 MΩ 12.5 pF 200 MHz 500 V 20±? Y
P6101A 2 m 7 ft 1 MΩ 54 pF 15 MHz 500 V n/a -
P6101A Opt.01 1 m 3.5 ft 1 MΩ 32 pF 34 MHz 500 V n/a -
P6101B 2 m 1 MΩ 100 pF 15 MHz 300 VRMS n/a -
P6102A 10× 2 m 10 MΩ 13.2 pF 60 MHz 500 V 36-55 pF Y
P6103 10× 2 m 10 MΩ 13.2 pF 50 MHz 500 V 15-35 pF -
P6104A 10× 1 m 10 MΩ 11.2 pF 100 MHz 500 V 15-35 pF Y
P6105A 10× 2 m 10 MΩ 11.2 pF 100 MHz 500 V 15-35 pF Y
P6106A 10× 2 m 10 MΩ 11.2 pF 250 MHz 500 V 15-35 pF Y
P6107A 10× 2 m 10 MΩ 13.0 pF 100 MHz 500 V 21-51 pF Y
P6108A 10× 2 m 10 MΩ 11.2 pF 100 MHz 500 V 15-35 pF -
P6109 10× 2 m 10 MΩ 13.2 pF 150 MHz 500 V 18-22 pF Y
P6109 Opt.01 10× 1.5 m 10 MΩ 11.8 pF 150 MHz 500 V 15-35 pF Y
P6109B 10× 2 m 10 MΩ 13.3 pF 100 MHz 420 V 15-35 pF Y
P6112 10× 2 m 10 MΩ 13.3 pF 100 MHz 300 VRMS 15-35 pF -
P6115 1.5 m 1 MΩ 64 pF 5 MHz 42 V n/a -
P6119 10× 2 m 10 MΩ 15.3 pF 100 MHz 500 V 15-35 pF -
1 MΩ 120 pF 8 MHz 350 V n/a
P6120 10× 1.5 m 10 MΩ 14 pF 60 MHz 500 V 23-47 pF -
3 m 10 MΩ 17 pF 50 MHz 23-51 pF
P6122 10× 1.5 m 10 MΩ 11 pF 100 MHz 500 V 15-35 pF -
P6125 1.5 m 5 MΩ 20 pF 250 MHz 250 V 15-33 pF -
P6130 10× 2 m 10 MΩ 13.2 pF 250 MHz 500 V 15-35 pF Y
P6131 10× 1.3 m 4 ft 10 MΩ 10.8 pF 300 MHz 500 V 14-18 pF Y
P6133 10× 2 m 10 MΩ 12.7 pF 150 MHz 500 V 10-25 pF Y
P6133 Opt. 25 10× 1.3 m 4 ft 10 MΩ 11.4 pF 150 MHz 500 V 10-25 pF Y
P6134C 10× 1.5 m 10 MΩ 10.5 pF 400 MHz 500 V 12-18 pF Y
P6135 10× 1.5 m 1 MΩ 11.3 pF 150 MHz 500 V 14-17 pF Y
P6135A red tip 10× 1.5 m 1 MΩ 10.5 pF 150 MHz 500 V 13-17 pF Y
P6135A black tip 11.0 pF 18-22 pF
P6135A blue tip 13.7 pF 45-49 pF
P6136 10× 1.3 m 4 ft 10 MΩ 10.8 pF 350 MHz 500 V 12-18 pF Y
P6136 Opt. 25 10× 1.3 m 4 ft 10 MΩ 10.8 pF 350 MHz 500 V 12-18 pF Y
P6137 10× 1.5 m 10 MΩ 10.8 pF 400 MHz 500 V 12-18 pF Y
P6139A 10× 1.3 m 4 ft 10 MΩ 8.0 pF 500 MHz 400 V 8-18 pF Y
P6139B 10× 1.3 m 4 ft 10 MΩ 8.0 pF 500 MHz 300 VRMS 8-18 pF Y
P6148A 10× 2 m 10 MΩ 13 pF 50 MHz 500 V 20-51 pF Y
P6149 10× 2 m 10 MΩ 15.5 pF 50 MHz 500 V 20-62 pF -
P6149A 10× 2 m 10 MΩ 13.0 pF 50 MHz 50 V 20-51 pF -
P6150 10× 1 m 500 Ω 0.15 pF 9 GHz 12.5 VRMS 50 Ω -
50 Ω n/a 3 GHz (Scope lim.)
P6156 1 0× 1.5 m 500 Ω 1.0 pF 3.5 GHz 15 VRMS 50 Ω Y
P6156 Opt. 25 100× 1.5 m 5 kΩ 2.1 pF 3 GHz 50 VRMS 50 Ω Y
P6156 Opt. 26 20× 1.5 m 1 kΩ 1.0 pF 3.5 GHz 22 VRMS 50 Ω Y
P6156 Opt. 27 1.5 m 50 Ω n/a 1.5 GHz 15 VRMS 50 Ω Y
P6562A 10× 1.3 m 4 ft 10 MΩ 11 pF 350 MHz 15 VRMS 12-35 pF Y
P6563A 20× 1.5 m 9.47 MΩ 4.7 pF 500 MHz 42 V 7-30 pF Y