2430A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Redirected page to 2430)
 
No edit summary
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
#redirect [[2430]]
{{Oscilloscope Sidebar
|manufacturer=Tektronix
|series=2400-series scopes
|model=2430A
|image=Tek2430.jpg
|caption=Tektronix 2430
|introduced=1988
|discontinued=1994
|summary=150 MHz, 100 MS/s portable digital scope
|designers=
|manuals=
* [[Media:070-6330-01.pdf|2430A Service SN B029999 and below]]
* [[Media:070-6330-02.pdf|2430A Service SN B030000 and up]]
* [[Media:070-6339-02.pdf|2430A Operator (6339-02)]]
* [[Media:070-6339-00.pdf|2430A Operator (6339-00)]]
* [[Media:070-6339-02.pdf|2430A Operator (6286-00)]]
* [[Media:070-6286-02.pdf|2430A Operator (6286-02)]]
* [[Media:070-6330-00.pdf|2430A Service]] (old version, OCR, 73M)
* [[Media:070-6338-00.pdf|2430A Programmer's Reference Guide]]
 
* [https://w140.com/mmm/tek-2430a.pdf 2430A Service] (256M)
* [https://w140.com/TEK2430A_serv.pdf 2430A Service (Mil)] (OCR, 10M)
'''Other'''
* [[Media:2430A-2432A-2440-catalog.pdf | 2430A/2432A/2440 catalog page]]
{{ROM Images}}
}}
The '''Tektronix 2430A''' is a portable dual-channel digital scope from the [[2000-series scopes|2000-series]], an updated version of the [[2430]].
<blockquote>
'''WARNING: '''Operation of the 2440, 2432, 2432A, 2430, and 2430A: A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
</blockquote>
{{BeginSpecs}}
{{Spec | Bandwidth | 150 MHz (Limit: 20, 50, Full) }}
{{Spec | Rise time | 2.33 ns (Repeat on, 16×averaging)}}
{{Spec | Sampling rate | 100 MS/s }}
{{Spec | Sampling type | Real time: 500 ns/Div and slower, Equivalent time 200 ns/Div and faster}}
{{Spec | Single event bandwidth  | 40 MHz (2430A) }}
{{Spec | Glitch capture | 2 ns }}
{{Spec | Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence }}
{{Spec | Resolution | 8 bit }}
{{Spec | Record length | 1024 samples }}
{{Spec | Input impedance| 1 MΩ // 15 pF or 50 Ω }}
{{Spec | Sweep speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)}}
{{Spec | Acquisition modes| Normal, Envelope (glitch capture), Average }}
{{Spec | Display modes| CH1, CH2, invert, add, multiply, X-Y }}
{{Spec | Cursors  | Volts, Time, Volts At Time, 1/Time, Slope }}
{{Spec | Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more }}
{{Spec | Interface | GPIB }}
{{Spec | Probes    | Two passive [[P6133]] 150 MHz ×10 voltage probes, 1.3 m }}
{{Spec | Features |
<small>
* Printer/plotter output
* On-screen help
* GPIB
* Autoprobe function with [[P6137]]
* Automatic measurements
* Extensive triggering capabilities
}}
</small>
{{Spec | Options |
<small>
* 03 - Word Recognizer ([[P6407]])
* 05 - Video Waveform Measurement System
* 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel
</small>
}}
{{EndSpecs}}
==Links==
{{Documents|Link=2430A}}
{{PatentLinks|2430A}}
 
==Pictures==
 
<gallery>
Tek 2430a front.jpg | 2430A
Tek 2430a trace.jpg | 2430A trace
Tek 2430a 1.jpg
Tek 2430a 2.jpg
Tek 2430a 3.jpg
Tek 2430a signal input board.jpg
Tek 2430a 4.jpg
Tek 2430a 5.jpg
Tek 2430a 6.jpg
Tek 2430a 7.jpg
Tek 2430a g1.jpg
Tek 2430a g2.jpg
Tek 2430a g3.jpg
Tek 2430a g4.jpg
Tek 2430a g5.jpg
Tek 2430a g6.jpg
Tek 2430a g7.jpg
Tek 2430a display.jpg | 2430A Display
</gallery>
 
==Components==
 
{{Parts|2430A}}
 
 
[[Category:2400 series scopes]]
[[Category:Digital storage scopes]]
 
[[Category:GPIB interface]]

Latest revision as of 03:42, 30 July 2024

Tektronix 2430A
150 MHz, 100 MS/s portable digital scope
Tektronix 2430

Produced from 1988 to 1994

Manuals
ROM Images
File Pos. Checksum
160-4398-04 U670 b8d76ded
160-4399-04 U680 f3f1f472
160-4400-04 U682 d2cc2120
160-4401-04 U690 943e4695
160-4402-04 U692 70cba0e9
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2430A is a portable dual-channel digital scope from the 2000-series, an updated version of the 2430.

WARNING: Operation of the 2440, 2432, 2432A, 2430, and 2430A: A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.

Key Specifications

Bandwidth 150 MHz (Limit: 20, 50, Full)
Rise time 2.33 ns (Repeat on, 16×averaging)
Sampling rate 100 MS/s
Sampling type Real time: 500 ns/Div and slower, Equivalent time 200 ns/Div and faster
Single event bandwidth 40 MHz (2430A)
Glitch capture 2 ns
Deflection 2 mV/div to 5 V/div in 1-2-5 sequence
Resolution 8 bit
Record length 1024 samples
Input impedance 1 MΩ // 15 pF or 50 Ω
Sweep speeds 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)
Acquisition modes Normal, Envelope (glitch capture), Average
Display modes CH1, CH2, invert, add, multiply, X-Y
Cursors Volts, Time, Volts At Time, 1/Time, Slope
Functions A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more
Interface GPIB
Probes Two passive P6133 150 MHz ×10 voltage probes, 1.3 m
Features

  • Printer/plotter output
  • On-screen help
  • GPIB
  • Autoprobe function with P6137
  • Automatic measurements
  • Extensive triggering capabilities
Options

Links

Documents Referencing 2430A

(no results)

Pictures

Components

Some Parts Used in the 2430A

Part Part Number(s) Class Description Used in
154-0850-01 154-0850-00 154-0850-01 CRT CRT 2424L 2430 2430A 2431L 2432 2439 2440 2445 2465 2465A 2465B
155-0238-00 155-0238-00 Hybrid integrated circuit preamplifier 11302A 2424L 2430 2430A 2432 2445 2465 2466 2467
155-0239-00 155-0239-00 155-0239-01 155-0239-02 Hybrid integrated circuit trigger 2424L 2430 2430A 2432 2445 2465 2467 2400-series scopes 11201 11401 11402
230-0001-50 230-0001-50 Hybrid integrated circuit phase clock array 2424L 2430 2430A 2432
230-0002-50 230-0002-50 Hybrid integrated circuit trigger logic array 2424L 2430 2430A 2432