230: Difference between revisions
(New page: The Tektronix 230 is a digital readout released in 1967 for the 568 oscilloscope. The 568 and 230 replaced the 567 and its digital unit plug-ins, the 6R1 and 6R1A. Unli...) |
No edit summary |
||
(44 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
The Tektronix 230 is a digital readout | {{Instrument Sidebar | ||
The 568 and 230 replaced the [[567]] and its digital unit plug-ins, | |class=Test Automation | ||
the [[6R1]] and [[6R1A]]. Unlike the 6R1 and 6R1A, the 230 is freestanding unit, | |manufacturer=Tektronix | ||
not a plug-in. | |series=568 | ||
6R1A was an evolutionary step forward from the 6R1, the circuitry | |model=230 | ||
evolutionary step forward from the 6R1A. The 230 does not contain any tubes or | |summary=Digital Unit | ||
tunnel diodes. | |image=230 operating.jpg | ||
|caption=Tektronix 230 front | |||
|introduced=1967 | |||
|discontinued= 1979(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:070-0635-00.pdf|Tektronix 230 Manual (earlier version, split schematics)]] | |||
* [[Media:070-0635-00_with_corrections.pdf|Tektronix 230 Manual (later version with corrections, whole schematics)]] | |||
* [[Media:Tek readout oscilloscopes 1968 catalog.pdf|"Digital Readout Introduction" in 1968 Catalog]] | |||
* [[Media:Tek r230 fcp sep 1967.pdf|Tektronix R230 Factory Calibration Procedure, September 1967]] | |||
* [[Media:Tek 230-r240 fcp march 1969.pdf|Tektronix R230 Factory Calibration Procedure, March 1969]] | |||
}} | |||
The '''Tektronix 230''' is a digital readout unit [[introduced in 1967]] for the [[568]] [[sampling oscilloscope]]. | |||
The 568 and 230 replaced the [[567]] and its digital unit plug-ins, the [[6R1]] and [[6R1A]]. Unlike the 6R1 and 6R1A, the 230 is freestanding unit, not a plug-in. | |||
Just like the 6R1A was an evolutionary step forward from the 6R1, the circuitry in the 230 is an evolutionary step forward from the 6R1A. | |||
The 230 was distributed by itself (usually for use with a 568) and also as a component of larger integrated test and measurement systems such as the [[S-3100]]. | |||
The 230 is programmable, which means that its circuitry can be controlled remotely, using multipin connectors located on the rear panel. | |||
The rear panel contains six connectors, four for remote control, one for connection to the 568 oscilloscope, and one that provides a binary-coded decimal representation of the number that is displayed on the digital readout on the 230. | |||
Like the 6R1 and 6R1A, the 230 allows upper and lower limits to be set on voltage or time, and it has front-panel lamps and rear panel signals that show whether the current measurement is below the lower limit, within the limits, or above the upper limit. | |||
The minimal system configuration with a 230 is just the 230 connected to the 568. | |||
The typical cable for connecting the [[568]] to the [[230]] is the [[012-0119-01]]. | |||
Five out of six of the connectors on the rear panel of the 230 can be ignored for basic use. | |||
J101 on the rear of the 230 connects to the J101 on the rear of the 568. | |||
This connection is required since it brings the sampled signal from the 568 to the 230. | |||
The 230 does not control the 568. | |||
The 568 sends signals and the 230 displays them on the [[Nixie tube]] readout and generates control signals on its rear panel connectors. | |||
One exception to this is the CRT intensifier signal, which is sent by the 230 to the 568. | |||
This signal intensifies the trace in the various zones, which are configured on the 230 or remotely using a [[241|241 programmer]]. | |||
{{MissingSpecs}} | |||
==Links== | |||
* [http://www.barrytech.com/tektronix/vintage/tek230.html Tektronix 230 @ barrytech.com] | |||
{{Documents|Link=230}} | |||
{{PatentLinks|230}} | |||
==Internals== | |||
The 230 does not contain any tubes or [[tunnel diodes]]. | |||
It makes some use of integrated circuits and extensive use of [http://en.wikipedia.org/wiki/Reed_relay reed relays]. | |||
The power supply in the Tektronix 230 is linear and provides regulated of +50 V, +12 V, +3.8 V, +1.75 V, −3.5 V, and −50 V. It also provides a +255 V unregulated output. | |||
The power supply transformer, electrolytic capacitors, and output transistors are part of the chassis, not a removable unit. The regulator circuits are on a circuit card. | |||
Most of the circuitry of the 230 is on circuit cards that plug into a backplane bus. | |||
==See Also== | |||
* [[012-0131-00|012-0131-00 Interconnecting Cable]] | |||
* [[S-3110]] | |||
==Pictures== | |||
<gallery> | |||
230 front.jpg | 230's Front | |||
230 insides.jpg | 230's insides | |||
230 zone generator card.jpg | Zone generator PCB | |||
230 comparator card.jpg | comparator PCB | |||
230 memory card.jpg | memory PCB | |||
230 clock board.jpg | clock PCB | |||
Tek 230 synchronizer board.jpg|synchronizer PCB | |||
230 backplane.jpg | backplane | |||
230 power supply.jpg | power supply | |||
230 rear.jpg | 230's rear | |||
230_568_0.JPG | 230 and 568 measuring rise time | |||
230_ext_1.JPG | 230 extender in storage-state | |||
230_ext_2.JPG | 230 extender in stacked-state for using | |||
Tek 230 568 s-1 voltage measurement.jpg | Voltage measurement with 230, 568, and S-1 | |||
Tek 230 568 s-1 risetime measurement.jpg | Risetime measurement with 230, 568, and S-1 | |||
</gallery> | |||
==Components== | |||
{{Parts|230}} | |||
[[Category:Accessories]] |
Latest revision as of 06:41, 8 November 2024
The Tektronix 230 is a digital readout unit introduced in 1967 for the 568 sampling oscilloscope.
The 568 and 230 replaced the 567 and its digital unit plug-ins, the 6R1 and 6R1A. Unlike the 6R1 and 6R1A, the 230 is freestanding unit, not a plug-in. Just like the 6R1A was an evolutionary step forward from the 6R1, the circuitry in the 230 is an evolutionary step forward from the 6R1A.
The 230 was distributed by itself (usually for use with a 568) and also as a component of larger integrated test and measurement systems such as the S-3100.
The 230 is programmable, which means that its circuitry can be controlled remotely, using multipin connectors located on the rear panel. The rear panel contains six connectors, four for remote control, one for connection to the 568 oscilloscope, and one that provides a binary-coded decimal representation of the number that is displayed on the digital readout on the 230. Like the 6R1 and 6R1A, the 230 allows upper and lower limits to be set on voltage or time, and it has front-panel lamps and rear panel signals that show whether the current measurement is below the lower limit, within the limits, or above the upper limit.
The minimal system configuration with a 230 is just the 230 connected to the 568. The typical cable for connecting the 568 to the 230 is the 012-0119-01. Five out of six of the connectors on the rear panel of the 230 can be ignored for basic use. J101 on the rear of the 230 connects to the J101 on the rear of the 568. This connection is required since it brings the sampled signal from the 568 to the 230. The 230 does not control the 568. The 568 sends signals and the 230 displays them on the Nixie tube readout and generates control signals on its rear panel connectors. One exception to this is the CRT intensifier signal, which is sent by the 230 to the 568. This signal intensifies the trace in the various zones, which are configured on the 230 or remotely using a 241 programmer.
Key Specifications
- please add
Links
Documents Referencing 230
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Service Scope 43 Apr 1967.pdf | Article | New From Tektronix, Inc. In 1967 | 1967 | 568 • 230 • 454 • 647A • C-40 • 1A4 • 1A5 • 3L5 • 200-1 | |
Service Scope 53 Dec 1968.pdf | Article | Digital Systems Come Of Age | John Bowne | 1968 | 3T5 • 3T6 • 3S5 • 3S6 • S-1 • S-2 • S-3 • S-4 • 568 • 230 |
Service scope dec 1968 ocr.pdf | Article | Digital Systems Come of Age | John Bowne | 1968 | 3T5 • 3T6 • 3S5 • 3S6 • S-1 • S-2 • S-3 • S-4 • 568 • 230 • 240 • 241 • 250 |
Service Scope 52 Oct 1968.pdf | Article | The State of the Art in Sampling | Al Zimmerman | 1968 | S-1 • S-2 • S-3 • S-4 • S-50 • S-51 • 285 • 3S1 • 3S2 • 3S5 • 3S6 • 3T2 • 3T5 • 3T6 • 3T77A • 568 • 230 |
Tekscope 1970 V2 N4 Aug 1970.pdf | Article | Automated Measurement Systems | 1970 | S-3150 • 568 • 230 • S-3110 • 241 • 240 | |
Tekscope 1971 V3 N1 Jan 1971.pdf | Article | Short Pulse Technique of Adjusting Wideband Amplifiers | Carl Battjes | 1971 | 7A16 • 109 • 568 • 230 |
Patents that may apply to 230
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 3453403A | Power selection device | Eldon Hoffman | 1966-08-18 | 1969-07-01 | 115 • 140 • 141 • 141A • 144 • 145 • 146 • 147 • 148 • 149 • 149A • 230 • 284 • 286 • 453 • 454 • 491 • 520A • 521A • 522 • 545B • 547 • 556 • 561B • 564B • 568 • 576 • 611 • 647A • 2101 • 2601 • 5030 • R5030 • 5031 • R5031 • 7503 • 7504 • 7704 • 7704A • 7904 • R7903 |
Internals
The 230 does not contain any tubes or tunnel diodes. It makes some use of integrated circuits and extensive use of reed relays.
The power supply in the Tektronix 230 is linear and provides regulated of +50 V, +12 V, +3.8 V, +1.75 V, −3.5 V, and −50 V. It also provides a +255 V unregulated output. The power supply transformer, electrolytic capacitors, and output transistors are part of the chassis, not a removable unit. The regulator circuits are on a circuit card.
Most of the circuitry of the 230 is on circuit cards that plug into a backplane bus.
See Also
Pictures
-
230's Front
-
230's insides
-
Zone generator PCB
-
comparator PCB
-
memory PCB
-
clock PCB
-
synchronizer PCB
-
backplane
-
power supply
-
230's rear
-
230 and 568 measuring rise time
-
230 extender in storage-state
-
230 extender in stacked-state for using
-
Voltage measurement with 230, 568, and S-1
-
Risetime measurement with 230, 568, and S-1
Components
Some Parts Used in the 230
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
Fairchild 9960 | 156-0001-00 | Monolithic integrated circuit | nixie decoder/driver | X381 • 230 |