3T2: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
 
(11 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar
title=Tektronix 3T2 |
|manufacturer=Tektronix
summary=Sampling Timebase |
|series=560-series scopes
series=[[560-series scopes]] |
|type=3T2
image=3t2 front.jpg |
|summary=Random sampling sweep plug-in
caption=Tektronix 3T2 |
|image=Tek 3t2 front.jpg
introduced=1967 |
|caption=Tektronix 3T2
discontinued=(?) |
|introduced=1967
manuals=
|discontinued=(?)
* [http://bama.edebris.com/download/tek/3t2/3t2.djvu Tektronix 3T2 Manual (DjVu)]
|manuals=
* [http://w140.com/tek_3t2.pdf Tektronix 3T2 Manual (PDF)]
* [[Media:070-0631-00.pdf|Tektronix 3T2 Manual]] (OCR)
* [[Media:Tek 3t2 fcp aug 1967.pdf|Tektronix Factory Calibration Procedure (PDF)]]
* [[Media:Tek 3t2 fcp aug 1967.pdf|Tektronix Factory Calibration Procedure]]
* [[Media:Tek 3t2 cal outline.pdf|Tektronix 3T2 Calibration Outline]] (OCR)
* [[Media:Tek 3T2 schematics.pdf|Tektronix 3T2 Schematics]] (full-page scan)
}}
}}
The '''Tektronix 3T2''' is a [[sampling oscilloscope|sampling]] time-base plug-in
The '''Tektronix 3T2''' is a [[sampling oscilloscope|sampling]] time-base plug-in for [[560-series scopes]].  
for [[560-series scopes]].  


==Specifications==
==Specifications==
Line 20: Line 21:
UHF SYNC works up to 3 GHz.   
UHF SYNC works up to 3 GHz.   
The amount of jitter depends on the mode of operation.   
The amount of jitter depends on the mode of operation.   
The lowest jitter, specified to be less than 2 ps, is obtained with  
The lowest jitter, specified to be less than 20 ps, is obtained with an external 50 Ω trigger source of at least 150 mV.   
an external 50 Ω trigger source of at least 150 mV.   


==Links==
==Links==
* [[Media:Service Scope 46 Oct 1967.pdf | Service Scope 46, October 1967]]
{{Documents|Link=3T2}}
{{PatentLinks|3T2}}


==Pictures==
==Pictures==
<gallery>
<gallery>
3t2 front.jpg
Tek 3t2 front.jpg
<!--3t2 front.jpg-->
3t2 left.jpg
3t2 left.jpg
3t2 trigger closeup.jpg
3t2 trigger closeup.jpg

Latest revision as of 11:01, 19 June 2024

Tektronix 3T2
Random sampling sweep plug-in
Tektronix 3T2

Compatible with 560-series scopes

Produced from 1967 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T2 is a sampling time-base plug-in for 560-series scopes.

Specifications

Triggering works up to 100 MHz. The 3T2 has a random sampling mode. UHF SYNC works up to 3 GHz. The amount of jitter depends on the mode of operation. The lowest jitter, specified to be less than 20 ps, is obtained with an external 50 Ω trigger source of at least 150 mV.

Links

Documents Referencing 3T2

Document Class Title Authors Year Links
Service Scope 46 Oct 1967.pdf Article Random Sampling - A New Way of Fast Pulse Display Al Zimmerman 1967
Service Scope 52 Oct 1968.pdf Article The State of the Art in Sampling Al Zimmerman 1968

Patents that may apply to 3T2

Page Title Inventors Filing date Grant date Links
Patent US 3611003A Oscilloscope signal sampling system George Frye 1969-05-26 1971-10-05

Pictures