TDS620: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (Removed redundant manual links.)
No edit summary
 
(25 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |manufacturer=Tektronix |series=TDS series scopes|designers=|
{{Oscilloscope Sidebar
model= TDS620 |
|manufacturer=Tektronix
image=tds620.jpg |
|series=TDS series scopes
caption=Tektronix TDS620 |
|model=TDS620
introduced=1993 |
|summary=500 MHz, 2 GS/s, 2-Ch digital scope
discontinued=(?) |
|image=tds620.jpg
summary=500 MHz, 2 GS/s, 2-Ch digital scope |
|caption=Tektronix TDS620
manuals=
|introduced=1993
|discontinued=(?)
|designers=
|manuals=
'''TDS620'''
* [[Media:070-8507-00.pdf|TDS620 Service Manual 070-8507-00]]
* [[Media:070-8506-01.pdf|TDS620 User Manual 070-8506-01]]
* [[Media:070-8649-00.pdf|TDS620 Performance Verification 070-8649-00]]
* [[Media:070-8318-05.pdf|TDS Series Programmer 070-8318-05]]
 
'''TDS620A'''
* [[Media:070-8709-06.pdf|TDS620A Programmer 070-8709-06]]
* [[Media:070-8709-07.pdf|TDS620A Programmer 070-8709-07]]
* [[Media:070-8711-02.pdf|TDS620A Reference 070-8711-02]]
* [[Media:070-8715-04.pdf|TDS620A User Manual 070-8715-04]]
* [[Media:070-8718-04.pdf|TDS620A Service Manual 070-8718-04]]
 
'''TDS620B'''
* [[Media:070-9382-01.pdf|TDS620B Reference 070-9382-01]]
* [[Media:070-9384-01.pdf|TDS620B Performance Verification and Specifications 070-9384-01]]
* [[Media:070-9386-03.pdf|TDS620B Service Manual 070-9386-03]]
* [[Media:070-9702-00.pdf|TDS620B Programmer Manual 070-9702-00]]
* [[Media:070-9556-00.pdf|TDS620B etc Programmer Manual 070-9556-00]]
* [[Media:070-9719-00.pdf|TDS620B Digitizing Oscilloscopes 070-9719-00]]
* [[Media:070-9720-01.pdf|TDS620B Performance Verification and Specifications 070-9720-01]]
* [[Media:070-9721-02.pdf|TDS620B Service Manual 070-9721-02]]
* [[Media:070-9861-00.pdf|TDS620B Reference 070-9861-00]] / <small>[[Media:070-9861-00 c2.pdf|Alternate copy]]</small>
* [[Media:070-9869-00.pdf|TDS620B User 070-9869-00]] / <small>[[Media:070-9869-00 c2.pdf|Alternate copy]]</small>
* [[Media:070-9874-02.pdf|TDS620B Technical Reference 070-9874-02]]
* [[Media:070-9875-04.pdf|TDS620B Service 070-9875-04]]
* [[Media:070-9876-00.pdf|TDS620B Programmer manual 070-9876-00]]
* [[Media:071-0090-01.pdf|TDS620B User Manual Supplement 071-0090-01]] / <small>[[Media:071-0090-01 c2.pdf|Alternate copy]]</small>
* [[Media:071-0134-00.pdf|TDS600B User Manual Japanese 071-0134-00]]
* [[Media:071-0135-00.pdf|TDS620B Performance Verification and Specifications 071-0135-00]]
* [[Media:071-0136-00.pdf|TDS620B Service Manual 071-0136-00]]
* [[Media:55W-10066-6.pdf|Sales Brochure]]
 
'''Common'''
'''Common'''
* [[Media:045-0213-00.pdf|CRT Filter Retainer Upgrade Kit 045-0213-00]]
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]]
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]]
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface 070-8709-02]]
* [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]]
* [[Media:070-8567-01.pdf|Option 13 RS-232/Centronics Hardcopy Interface Instruction Manual 070-8567-01]]
* [[Media:070-8582-01.pdf|Option 2F Advanced DSP Math Instruction Manual 070-8582-01]]
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]]
* [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]]
* [[Media:070-9636-02.pdf|TDS Family Opt 05 Video Trigger Interface Install 070-9636-02]]
* [[Media:070-9636-02.pdf|TDS Family Opt 05 Video Trigger Interface Install 070-9636-02]]
* [[Media:070-9785-03.pdf|Wavestar Software User Manual 070-9785-03]]
* [[Media:071-0220-07.pdf|WSTRO & WSTROU WaveStar Software User Manual 071-0220-07]]
* [[Media:071-0220-09.pdf|WSTRO WaveStar Software User Manual 071-0220-09]]
* [[Media:071-0817-00.pdf|WSTRO, WSTROU & WSTRM WaveStar Software, AD007 GPIB-LAN Adapter, TDS3EM Ethernet Comms Module User Manual 071-0817-00]]
* [[Media:071-1140-03.pdf|WaveStar Software, Wavestar Reader, AD007 GPIB-LAN Adapter Software Solutions Installation 071-1140-03]]
* [[Media:55W-8862-00.PDF|Sales Brochure]]


'''TDS600A'''
'''Schematics'''
* [[Media:070-8709-06.pdf|TDS400A/500A/600A/700A Programmer 070-8709-06]]
* [[Media:TDS544A_A17-A19(PS).pdf|Full schematics of A17 - A19 Power Supply boards (TDS620, 640, 640A & 644A, same as TDS544A)]]
* [[Media:070-8709-07.pdf|TDS400A/500A/600A/700A Programmer 070-8709-07]]
* [[Media:TDS644A A10(Acq).pdf|TDS644 A10 Acquisition Board Schematic, also applies to TDS620]]
* [[Media:070-8711-02.pdf|TDS500A/600A Reference 070-8711-02]]
}}
* [[Media:070-8715-04.pdf|TDS 620A, 640A, 644A User Manual 070-8715-04(PDF)]]
The '''Tektronix TDS620''' and '''TDS620A''' are 500 MHz, 2 GS/s 2-channel digital storage scopes with a monochrome screen, with 2000 points maximum record length per channel. <br>
* [[Media:070-8718-04.pdf|TDS 620A, 640A, 644A Service Manual 070-8718-04(PDF)]]
The '''Tektronix TDS620B''' has 2.5 GS/s sample rate and 15,000 points maximum record length per channel.<br>
Two plus Two channel operation allows up to two of the four channels to be displayed simultaneously.<br>
Channels not displayed can be used to couple a triggering signal to the oscilloscope.


'''TDS600B'''
{{BeginSpecs}}
* [[Media:070-9382-01.pdf|TDS500B/600B/700A Reference 070-9382-01]]
{{Spec | Bandwidth  | 500 MHz }}
* [[Media:070-9384-01.pdf|TDS500B/600B/700A Performance Verification and Specifications 070-9384-01]]
{{Spec | Sample rate | 2 GS/s (TDS620, TDS620A), 2,5 GS/s (TDS620B) on all channels }}
* [[Media:070-9386-03.pdf|TDS500B/600B/700A Service Manual 070-9386-03]]
{{Spec | Number of Channels | 2 + 2 }}
* [[Media:070-9719-00.pdf|TDS500B/600B/700A Digitizing Oscilloscopes 070-9719-00]]
{{Spec | Vertical Sensitivity| 1 mV to 10 V/div with calibrated fine adjustment }}
* [[Media:070-9721-02.pdf|TDS500B/600B/700A Service Manual 070-9721-02]]
{{Spec | Resolution  | 8 bit }}
* [[Media:070-9861-00.pdf|TDS500C/600B/700C Reference 070-9861-00]] / <small>[[Media:070-9861-00 c2.pdf|Alternate copy]]</small>
{{Spec | Time Base Range| 500 ps to 5 s/div (TDS620), 200 ps to 10 s/div (TDS620A, TDS620B) }}
* [[Media:070-9869-00.pdf|TDS500C/600B/700C User 070-9869-00]] / <small>[[Media:070-9869-00 c2.pdf|Alternate copy]]</small>
{{Spec | Record length | 2000 points (TDS620, TDS620A), 15,000 points (TDS620B) }}
* [[Media:070-9874-02.pdf|TDS500C/600B/700C Technical Reference 070-9874-02]]
{{Spec | Acquisition modes | sample, envelope, average, high-resolution, peak-detect }}
* [[Media:070-9875-04.pdf|TDS500C/600B/700C Service 070-9875-04]]
{{Spec | Display  | Monochrome }}
* [[Media:071-0090-01.pdf|TDS500C/600B/700C User Manual Supplement 071-0090-01]] / <small>[[Media:071-0090-01 c2.pdf|Alternate copy]]</small>
{{Spec | Trigger modes | Edge, logic, pulse; Video trigger with option 05 ([[NTSC]], [[SECAM]], [[PAL]], HDTV, and FlexFormat) }}
* [[Media:071-0135-00.pdf|TDS500D/600B/700D Performance Verification and Specifications 071-0135-00]]
{{Spec | Storage | 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive }}
* [[Media:071-0136-00.pdf|TDS500D/600B/700D Service Manual 071-0136-00]]
{{Spec | I/O | Full GPIB programmability }}
{{Spec | Hardcopy | Using [[GPIB]], [[RS-232]], or Centronics ports }}
{{EndSpecs}}


'''TDS600C'''
==Software==
* [[Media:071-0130-00.pdf|TDS500D/600C/700D User Manual 071-0130-00]]
* [[Media:TDS600_Field_Adjustment_Software.zip|TDS620 Field Adjustment Software]] (ZIP)
* [[Media:071-0130-03.pdf|TDS500D/600C/700D User Manual 071-0130-03]]
* [[Media:TDS600A_Field_Adjustment_Software.zip|TDS620A Field Adjustment Software]] (ZIP)
* [[Media:071-0273-02.pdf|TDS500D/600C/700D User Manual Supplement 071-0273-02]]
* [[Media:TDS600B_Field_Adjustment_Software_063-1908-01.zip|TDS620B Field Adjustment Software 063-1908-01]] (ZIP)
* [[Media:071-0273-03.pdf|TDS500D/600C/700D User Manual Supplement EN/FR/DE/KR/JP 071-0273-03]]
<br>
* [[Media:071-0504-00.pdf|TDS500D/600C/700D Reference 071-0504-00]]
* [[Media:063-1134-00 V1.2.zip|TDS Family Programming Examples Software 063-1134-00 V1.2]] (ZIP)
* [[Media:071-0627-02.pdf|TDS500D/600C/700D/714L Service 071-0627-02]] / <small>[[Media:071-0627-02 c2.pdf|Alternate copy]]</small>
* [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP)
* [[Media:071-0630-03.pdf|TDS500D/600C/700D/714L Performance Verification and Specifications 071-0630-03]]
* [[Media:066-0087-00.zip|AWE Drivers For Tektronix Oscilloscopes 066-0087-00]] (ZIP)
* [[Media:066-0104-00.zip|File Transfer Utility From TDS Scope To PC 066-0104-00]] (ZIP)
* [[Media:Ttip.zip|Telecom Test and I-Pattern Software TTiP 066-0119-00]] (ZIP)
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP)
* [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP)
* [[Media:066-0176-00.zip|WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00]] (ZIP)
* [[Media:066-0177-00.zip|Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00]] (ZIP)
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP)
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP)
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP)
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP)
* [[Media:066-0196-00.zip|Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00]] (ZIP)
* [[Media:066-0197-00.zip|Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00]] (ZIP)
* [[Media:066-0198-00.zip|Transfer Setups Between TDS Oscilloscopes 066-0198-00]] (ZIP)
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP)
* [[Media:066-0489-00.zip|TDS Series WFM File Formatter 066-0489-00]] (ZIP)
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN]] (ZIP, 102MB) ''Product Key: WSTRO618650124''


==Schematics==
==Firmware==
* [http://hakanh.com/dl/docs/hardtofind/TDS544A_A17-A19(PS).pdf Full schematics of A17 - A19 Power Supply boards (TDS620, TDS640, TDS640A & TDS644A, same as TDS544A)]
* [[Media:Tek TDS620 firmware v2.04e.bin|TDS620 v2.04e Firmware]]
}}
* [[Media:TDS620B v4.2e Firmware.zip|TDS620B v4.2e Firmware]] (ZIP)
* [[Media:TDS620B_v4.4.1e_Firmware.zip|TDS620B v4.4.1e Firmware]] (ZIP)
* [[Media:Tek TDS620 nvram U1107 contents.bin|Contents of TDS620 NVRAM]]
 
==Options==
* 05 - Video Trigger                              - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
* 1M - 4M acquisition length                      - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel.
* 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
* 1F - Floppy disk drive                          - Add 3.5 inch, 1.44 MByte floppy disc drive.
* 2F - Advanced DSP math                          - Add advanced DSP math features such as FFT, integration, and differentiation.


The '''Tektronix TDS620''' is a 500 MHz, 2 GS/s dual-channel digital storage scope.
==Optional Accessories==
* 1K - Add K420 scope cart
* 1R - Rackmount kit
* 2D - Delete standard 2 P6205 probes
* 22 - (TDS620A) Add 2 each P6139A passive probes
* 23 - (TDS620A) Add 4 each P6245 active FET probes
* 24 - (TDS620B) Add 4 each P6139A passive probes
* D1 - Calibration data report


It has [[Tekprobe BNC connector]]s on both input channels.
==TDS620A Included Accessories==
* 2x P6205 FET Probes
* 070-8711-02 - Reference Manual
* 070-8711-01 - User Manual
* 200-3696-01 - Front cover
* 161-0230-01 - US power cord


The quad-channel version is the [[TDS640]].
==TDS620B Included Accessories==
* 2x P6139A FET Probes
* 070-9382-00 - Quick Reference Guide
* 063-2773-00 - Programmers Manual in MS-Help format on floppy disk
* 070-6869-00 - User Manual
* 070-9874-02 - Technical Reference Manual
* 200-3696-01 - Front cover
* 161-0230-01 - US power cord


{{BeginSpecs}}
==Recommended Accessories==
{{Spec | Bandwidth        | 500 MHz                  }}
* 012-0991-01 - 1m GPIB cable
{{Spec | Sampling rate    | 2 GS/s on both channels }}
* 012-0991-00 - 2m GPIB cable
{{Spec | Time base        | 500 ps/Div to 5 s/Div    }}
* 012-1298-00 - RS-232 cable
{{Spec | Deflection      | 1 mV/Div to 10 V/Div    }}
* 012-1250-00 - Centronics cable
{{Spec | Resolution      | 8 bits                  }}
* 016-0909-01 - Soft-sided carrying case
{{Spec | Record length    | 500 to 2000 points      }}
* 016-01135-00 - Transit case
{{Spec | Input impedance  | 1 MΩ // 10 pF, or 50 Ω  }}
* K420 - Scope cart
{{Spec | Interface        | GPIB standard            }}
{{Spec | Options |
* Centronics interface
* RS-232 interface
* FFT, integration and differentiation
}}
{{EndSpecs}}


==Software==
==Links==
* [[Media:TDS300-400-500-600-700-800_AWE_Drivers_066008700.zip|Tektronix TDS300, 400, 500, 600, 700, 800 AWE Drivers 066008700]] (ZIP)
* Tek Forum threads:
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN]] (ZIP, 102MB) ''Product Key: WSTRO618650124''
** [http://forum.tek.com/viewtopic.php?f=568&t=140017/  Recovering the unit from a bricked state]
** [http://forum.tek.com/viewtopic.php?f=568&t=139999&hilit=TDS784/ Firmware updating]
** [http://forum.tek.com/viewtopic.php?f=568&t=138168&hilit=TDS784/ Backing up and restoring calibration data]
* EEVBlog Forum Threads:
** [http://www.eevblog.com/forum/testgear/hackingupgrading-old-scope-(tds754d)/ EEVBlog Forum thread on TDS options and how to enable them]
** [https://www.eevblog.com/forum/repair/unified-tektool-released-!-(firmware-flash-tools-for-old-tds-series)/ Firmware update via GPIB]
** [https://www.eevblog.com/forum/repair/tektronix-tds500-700-debug-konscole-interface/ Serial debug and console interface card for TDS500-700 series]
** [https://www.eevblog.com/forum/testgear/console-port-debug-adapter-for-tek-tds500-tds600-and-tds700-series-scopes/ Console port debug adapter for TDS500-700 series]
* [https://simmconnlabscom.ipage.com/store/page5.html Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes]
* [https://www.tek.com/support/faqs/i-lost-my-wavestar-keycode-how-can-i-get-it-back Wavestar Product Key]
* [https://www.hakanh.com/dl/TDSErrLog.htm TDS error log viewer]
* [http://www.ko4bb.com/getsimple/index.php?id=enable-tds754d-options Unlocking software options - ko4bb.com]


{{MissingPics}}
{{MissingPics}}


==Components==
{{Parts|TDS620}}
{{Parts|TDS620A}}
{{Parts|TDS620B}}


[[Category:TDS600 series scopes]]
[[Category:TDS600 series scopes]]

Latest revision as of 06:42, 6 December 2023

Tektronix TDS620
500 MHz, 2 GS/s, 2-Ch digital scope
Tektronix TDS620

Produced from 1993 to (?)

Manuals

TDS620

TDS620A

TDS620B

Common

Schematics

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix TDS620 and TDS620A are 500 MHz, 2 GS/s 2-channel digital storage scopes with a monochrome screen, with 2000 points maximum record length per channel.
The Tektronix TDS620B has 2.5 GS/s sample rate and 15,000 points maximum record length per channel.
Two plus Two channel operation allows up to two of the four channels to be displayed simultaneously.
Channels not displayed can be used to couple a triggering signal to the oscilloscope.

Key Specifications

Bandwidth 500 MHz
Sample rate 2 GS/s (TDS620, TDS620A), 2,5 GS/s (TDS620B) on all channels
Number of Channels 2 + 2
Vertical Sensitivity 1 mV to 10 V/div with calibrated fine adjustment
Resolution 8 bit
Time Base Range 500 ps to 5 s/div (TDS620), 200 ps to 10 s/div (TDS620A, TDS620B)
Record length 2000 points (TDS620, TDS620A), 15,000 points (TDS620B)
Acquisition modes sample, envelope, average, high-resolution, peak-detect
Display Monochrome
Trigger modes Edge, logic, pulse; Video trigger with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat)
Storage 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive
I/O Full GPIB programmability
Hardcopy Using GPIB, RS-232, or Centronics ports

Software


Firmware

Options

  • 05 - Video Trigger - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
  • 1M - 4M acquisition length - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel.
  • 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
  • 1F - Floppy disk drive - Add 3.5 inch, 1.44 MByte floppy disc drive.
  • 2F - Advanced DSP math - Add advanced DSP math features such as FFT, integration, and differentiation.

Optional Accessories

  • 1K - Add K420 scope cart
  • 1R - Rackmount kit
  • 2D - Delete standard 2 P6205 probes
  • 22 - (TDS620A) Add 2 each P6139A passive probes
  • 23 - (TDS620A) Add 4 each P6245 active FET probes
  • 24 - (TDS620B) Add 4 each P6139A passive probes
  • D1 - Calibration data report

TDS620A Included Accessories

  • 2x P6205 FET Probes
  • 070-8711-02 - Reference Manual
  • 070-8711-01 - User Manual
  • 200-3696-01 - Front cover
  • 161-0230-01 - US power cord

TDS620B Included Accessories

  • 2x P6139A FET Probes
  • 070-9382-00 - Quick Reference Guide
  • 063-2773-00 - Programmers Manual in MS-Help format on floppy disk
  • 070-6869-00 - User Manual
  • 070-9874-02 - Technical Reference Manual
  • 200-3696-01 - Front cover
  • 161-0230-01 - US power cord

Recommended Accessories

  • 012-0991-01 - 1m GPIB cable
  • 012-0991-00 - 2m GPIB cable
  • 012-1298-00 - RS-232 cable
  • 012-1250-00 - Centronics cable
  • 016-0909-01 - Soft-sided carrying case
  • 016-01135-00 - Transit case
  • K420 - Scope cart

Links

Pictures

  • please add

Components

Some Parts Used in the TDS620

(no results)


Some Parts Used in the TDS620A

(no results)


Some Parts Used in the TDS620B

Part Part Number(s) Class Description Used in
H2462 Hybrid integrated circuit oscilloscope channel input module TDS510B TDS520B TDS524B TDS540B TDS544B TDS620B TDS640B TDS644B TDS680B TDS684B TDS714 TDS724 TDS744 TDS754 TDS782 TDS784 TDS794