2430: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
(14 intermediate revisions by 5 users not shown) | |||
Line 6: | Line 6: | ||
|caption=Tektronix 2430 | |caption=Tektronix 2430 | ||
|introduced=1986 | |introduced=1986 | ||
|discontinued= | |discontinued=1998 | ||
|summary=150 MHz, 100 MS/s portable digital scope | |summary=150 MHz, 100 MS/s portable digital scope | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-5497-00.pdf | 2430 User Reference 070-5497-00]] | |||
* [[Media:070-5497-00.pdf| | * [[Media:070-4918-00.pdf | 2430 Operators 070-4918-00]] (OCR) | ||
* [[Media:070-4918-00.pdf| | * [[Media:070-4917-00.pdf | 2430 Service 070-4917-00]] <small>(good scan, OCRed, compressed)</small> | ||
* [[Media:070-4917-00_1991.pdf | 2430 Service 070-4917-00]] <small>(average scan with late mods)</small> | |||
* [[Media:070-4917-00.pdf|2430 Service]] | * [[Media:070-4917-00_large.pdf | 2430 Service 070-4917-00]] (345M) <small>(good scan)</small> | ||
* [[Media:070-4917-00_1991.pdf|2430 Service]] | * [[Media:37W-6136.pdf | Tektronix 2430 Engineering Notes]] | ||
{{ROM Images}} | |||
* [[Media:070- | |||
* [[Media: | |||
}} | }} | ||
The '''Tektronix 2430''' is a portable dual-channel digital scope from the [[2000-series scopes|2000-series]]. | The '''Tektronix 2430''' is a portable dual-channel digital scope from the [[2000-series scopes|2000-series]]. The updated [[2430A]] was introduced in 1998. | ||
<blockquote> | |||
'''WARNING: '''Operation of the 2440, 2439, 2432, 2432A, 2431L, 2430, 2430A and 2424L: The A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling. | |||
</blockquote> | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | | {{Spec | Bandwidth | 150 MHz (Limit: 20, 50, Full) }} | ||
{{Spec | Sampling | {{Spec | Rise time | 2.33 ns (Repeat on, 16×averaging)}} | ||
{{Spec | | {{Spec | Sampling rate | 100 MS/s }} | ||
{{Spec | | {{Spec | Sampling type | Real time: 500 ns/Div and slower, Equivalent time 200 ns/Div and faster}} | ||
{{Spec | | {{Spec | Single event bandwidth | 40 MHz (2430A) }} | ||
{{Spec | Resolution | 8 | {{Spec | Glitch capture | 2 ns }} | ||
{{Spec | | {{Spec | Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence }} | ||
{{Spec | | {{Spec | Resolution | 8 bit }} | ||
{{Spec | | {{Spec | Record length | 1024 samples }} | ||
{{Spec | | {{Spec | Input impedance| 1 MΩ // 15 pF or 50 Ω }} | ||
{{Spec | Sweep speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)}} | |||
{{Spec | Acquisition modes| Normal, Envelope (glitch capture), Average }} | |||
{{Spec | Display modes| CH1, CH2, invert, add, multiply, X-Y }} | |||
{{Spec | Cursors | Volts, Time, Volts At Time, 1/Time, Slope }} | |||
{{Spec | Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more }} | |||
{{Spec | Interface | GPIB }} | |||
{{Spec | Probes | Two passive [[P6133]] 150 MHz ×10 voltage probes, 1.3 m }} | {{Spec | Probes | Two passive [[P6133]] 150 MHz ×10 voltage probes, 1.3 m }} | ||
{{ | {{Spec | Features | | ||
<small> | |||
* Printer/plotter output | |||
* On-screen help | |||
* GPIB | |||
* Autoprobe function With [[P6137]] | |||
* Automatic measurements | |||
* Extensive triggering capabilities | |||
</small> | |||
}} | |||
{{Spec | Options | | |||
<small> | |||
* 03 - Word Recognizer ([[P6407]]) | * 03 - Word Recognizer ([[P6407]]) | ||
* 05 - Video Waveform Measurement System | * 05 - Video Waveform Measurement System | ||
* 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel | * 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel | ||
</small> | |||
}} | |||
{{EndSpecs}} | |||
==Links== | ==Links== | ||
* [https://www.youtube.com/watch?v=Qou6uHJV_6I 2430 repair] from IanScottJohnston @ YouTube | |||
{{Documents|Link=2430}} | |||
{{PatentLinks|2430}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | |||
Tek2430.jpg | |||
</gallery> | |||
{{BetterPics}} | |||
=== | ==Components== | ||
{{Parts|2430}} | |||
Proprietary ICs in the 2430 include: | Proprietary ICs in the 2430 include: | ||
A10U100 [[155-0238-00]] EXT TRIGGER PREAMP | A10U100 [[155-0238-00]] EXT TRIGGER PREAMP | ||
Line 93: | Line 85: | ||
A12U470 [[156-2380-00]] WAVEFORM PROCESSOR, CUST. | A12U470 [[156-2380-00]] WAVEFORM PROCESSOR, CUST. | ||
[[Category:2400 series scopes]] | [[Category:2400 series scopes]] |
Latest revision as of 04:23, 4 September 2024
The Tektronix 2430 is a portable dual-channel digital scope from the 2000-series. The updated 2430A was introduced in 1998.
WARNING: Operation of the 2440, 2439, 2432, 2432A, 2431L, 2430, 2430A and 2424L: The A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
Key Specifications
Bandwidth | 150 MHz (Limit: 20, 50, Full) |
---|---|
Rise time | 2.33 ns (Repeat on, 16×averaging) |
Sampling rate | 100 MS/s |
Sampling type | Real time: 500 ns/Div and slower, Equivalent time 200 ns/Div and faster |
Single event bandwidth | 40 MHz (2430A) |
Glitch capture | 2 ns |
Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence |
Resolution | 8 bit |
Record length | 1024 samples |
Input impedance | 1 MΩ // 15 pF or 50 Ω |
Sweep speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B) |
Acquisition modes | Normal, Envelope (glitch capture), Average |
Display modes | CH1, CH2, invert, add, multiply, X-Y |
Cursors | Volts, Time, Volts At Time, 1/Time, Slope |
Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more |
Interface | GPIB |
Probes | Two passive P6133 150 MHz ×10 voltage probes, 1.3 m |
Features |
|
Options |
|
Links
- 2430 repair from IanScottJohnston @ YouTube
Documents Referencing 2430
- (no results)
Pictures
Better pictures needed - please contribute
Components
Some Parts Used in the 2430
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
148-0140-00 | 148-0140-00 | Discrete component | miniature bi-stable relay actuator | 2424L • 2430 • 2431L • 2432 • 2439 • 2440 • 119-1445-02 |
154-0850-01 | 154-0850-00 • 154-0850-01 | CRT | CRT | 2424L • 2430 • 2430A • 2431L • 2432 • 2439 • 2440 • 2445 • 2465 • 2465A • 2465B |
155-0238-00 | 155-0238-00 | Hybrid integrated circuit | preamplifier | 11302A • 2424L • 2430 • 2430A • 2432 • 2445 • 2465 • 2466 • 2467 |
155-0239-00 | 155-0239-00 • 155-0239-01 • 155-0239-02 | Hybrid integrated circuit | trigger | 2424L • 2430 • 2430A • 2432 • 2445 • 2465 • 2467 • 2400-series scopes • 11201 • 11401 • 11402 |
230-0001-50 | 230-0001-50 | Hybrid integrated circuit | phase clock array | 2424L • 2430 • 2430A • 2432 |
230-0002-50 | 230-0002-50 | Hybrid integrated circuit | trigger logic array | 2424L • 2430 • 2430A • 2432 |
Proprietary ICs in the 2430 include:
A10U100 155-0238-00 EXT TRIGGER PREAMP A10U150 155-0239-02 A/B TRIGGER A10U320,A10U420 165-2235-02 LOW NOISE VERT PREAMP HYBRID A10U340,A10U440 165-1215-01 PEAK DETECTOR "(NOT REPLACEABLE - ORDER A1O)" A10U350,A10U450 165-2074-01 CCD/CLOCK DRIVER A10U370 230-0002-50 (M299) TRIGGER LOGIC ARRAY A10U470 230-0001-50 (M299) PHASE CLOCK ARRAY A11U670 156-2381-00 TIME BASE CONTROLLER (STD CELL) A12U470 156-2380-00 WAVEFORM PROCESSOR, CUST.