067-506: Difference between revisions
(categories) |
No edit summary |
||
(10 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
The Tektronix 067-506 | {{Instrument Sidebar | ||
|manufacturer=Tektronix | |||
|model=067-506 | |||
|class=Signal generator | |||
|series= | |||
|summary=Constant-amplitude signal generator | |||
|image=Tek 067-506 2.jpg | |||
|caption=Tektronix 067-506 front | |||
|introduced=(?) | |||
|discontinued=1966 | |||
|designers= | |||
|manuals= | |||
* [[Media:Tek 067-0506-00.pdf|Tektronix 067-0506-00 Manual]] | |||
* [[Media:Tek 067-0506-00 schematic.pdf|Tektronix 067-0506-00 Schematics]] | |||
}} | |||
The '''Tektronix 067-506''' (aka 067-0506-00) is a constant-amplitude signal generator for oscilloscope calibration. It was replaced by the [[191]] in 1966. | |||
{{BeginSpecs}} | |||
{{Spec | Frequency range | 50 kHz fixed, 0.35 − 100 MHz in 7 ranges }} | |||
{{Spec | Output | 2–6 V into 50 Ω, [[GR-874 connector]] }} | |||
{{EndSpecs}} | |||
==Links== | |||
{{Documents|Link=067-506}} | |||
{{PatentLinks|067-506}} | |||
==Internals== | |||
The 067-506 contains a feedback loop that maintains constant RF amplitude at the output connector regardless of small variations in load or internal variations, e.g., as the unit warms up. | |||
This is accomplished by using an envelope detector to measure the peak-to-peak output voltage, and using the envelope signal as feedback to set the plate voltage of the Colpitts RF oscillator, thereby controlling its swing. | |||
Unlike later instruments like the [[190]] and [[SG504]] that put the envelope detector in an output head, the 067-506 cannot compensate for variable losses in the output cable. | |||
The +450 V power supply in the 067-506 is unregulated. | |||
The instrument relies on the RF feedback loop to maintain stability of the RF output voltage with respect to line voltage variation. | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek 067-506.jpg | |||
Tek 067-506 2.jpg | |||
Tek 067-506 rear.jpg | |||
Tek 067-506 internal1.jpg | |||
Tek 067-506 internal2.jpg | |||
Tek 067-506 internal3.jpg | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|067-506}} | |||
[[Category:Signal generators]] | [[Category:Signal generators]] | ||
[[Category:GR874]] |
Latest revision as of 04:18, 16 October 2024
The Tektronix 067-506 (aka 067-0506-00) is a constant-amplitude signal generator for oscilloscope calibration. It was replaced by the 191 in 1966.
Key Specifications
Frequency range | 50 kHz fixed, 0.35 − 100 MHz in 7 ranges |
---|---|
Output | 2–6 V into 50 Ω, GR-874 connector |
Links
Documents Referencing 067-506
- (no results)
Internals
The 067-506 contains a feedback loop that maintains constant RF amplitude at the output connector regardless of small variations in load or internal variations, e.g., as the unit warms up. This is accomplished by using an envelope detector to measure the peak-to-peak output voltage, and using the envelope signal as feedback to set the plate voltage of the Colpitts RF oscillator, thereby controlling its swing.
Unlike later instruments like the 190 and SG504 that put the envelope detector in an output head, the 067-506 cannot compensate for variable losses in the output cable.
The +450 V power supply in the 067-506 is unregulated. The instrument relies on the RF feedback loop to maintain stability of the RF output voltage with respect to line voltage variation.
Pictures
Components
Some Parts Used in the 067-506
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
6DJ8 | 154-0187-00 • 154-0305-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 111 • 132 • 161 • 310A • 316 • 317 • 502 • 502A • 503 • 504 • 506 • 515 • 516 • 519 • 526 • 529 • RM529 • 533 • 535 • 536 • 543 • 544 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 556 • 561A • 561S • 564 • 565 • 567 • 581 • 581A • 585 • 585A • 661 • 1A4 • 1S1 • 60 • 2A60 • 63 • 2A63 • 67 • 2B67 • 3A1 • 3A1S • 3A2 • 3A3 • 3A6 • 3A7 • 72 • 3A72 • 75 • 3A75 • 4S2 • 51 • 3B1 • 3B1S • 3B2 • 3B3 • 3B4 • 3M1 • 3S76 • 3T77 • 3T77A • 9A1 • 9A2 • 1121 • 80 • 81 • 82 • 86 • B • O • W • Z • Telequipment D56 • Telequipment S32A • Telequipment D52 • S-311 • Telequipment TD51 • Telequipment S52 • Telequipment S51 • Telequipment Type A • TU-4 |
7119 | 154-0340-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 067-0532-00 • 191 • 3A3 • 3B4 • 3B5 • 516 • 545B • 549 • 661 • Chemtrix 205 |