{{Spec | Bandwidth | DC to 600 MHz plus 100 MHz and 20 MHz BWL filters }} | {{Spec | Bandwidth | DC to 600 MHz plus 100 MHz and 20 MHz BWL (Bandwidth Limit) filters }} | ||
{{Spec | Number of Inputs | 2 }} | {{Spec | Number of Inputs | 2 }} | ||
{{Spec | Rise time | 580 ps in 1 GHz mainframe such as the [[11402]], [[11402|11402A]]. [[11403]], [[11403|11403A]], [[DSA600|DSA601A]], or [[DSA600|DSA602A]] }} | {{Spec | Rise time | 580 ps in 1 GHz mainframe such as the [[11402]], [[11402|11402A]]. [[11403]], [[11403|11403A]], [[DSA600|DSA601A]], or [[DSA600|DSA602A]] }} | ||
Line 33: | Line 33: | ||
==Internals== | ==Internals== | ||
Each input channel has a separate 50 ohm attenuator containing, two X10 attenuators, a skin effect correction network, an AC coupling capacitor, a signal pickoff for the input protection network and a switch selecting the calibrator or signal input. In normal operation the calibrator signal to the attenuator is instead connected to ground. | |||
The 11A52 uses custom Tektronix-made chips including the [[155-0076-00]] (M94 overload detector) and [[M377]] amplifier chip. | |||
The signal output of the attenuator feeds the + input of the [[M377]] amplifier IC through a (blue) 50 ohm transmission line, one per input channel. The cable lengths set a standard delay per plugin. | |||
The M377's − input is connected to the ACVS (Analog Control Voltage System) output. | |||
The (differential) display outputs of the two amplifiers are hard-wired in parallel and drive the mainframe’s 50 Ω per side input impedance. The same is true of the trigger outputs of the two amplifiers. | |||
The version of the M377 used in the 11A52 has a 100 Ω output impedance per side so that two of them in parallel create a source impedance of 50 Ω per side. | |||
Each M377 amplifier's nominal common-mode output voltage is zero whether enabled or not. When not enabled, each M377 differential output is exactly zero by design. This fact is used during calibration by the plugin’s firmware to determine the mainframe’s imbalance and compensate for it during normal operation. | |||
In the 11A52, the digital output of the M94 overload detectors (one per channel) are received by the microprocessor. | In the 11A52, the digital output of the M94 overload detectors (one per channel) are received by the microprocessor. |
Revision as of 16:49, 4 January 2023
The Tektronix 11A52 is a 600 MHz dual-channel plug-in for 11000-series and DSA600-series scopes. It has Tekprobe BNC connector inputs.
Key Specifications
Bandwidth | DC to 600 MHz plus 100 MHz and 20 MHz BWL (Bandwidth Limit) filters |
---|---|
Number of Inputs | 2 |
Rise time | 580 ps in 1 GHz mainframe such as the 11402, 11402A. 11403, 11403A, DSA601A, or DSA602A |
Deflection | 1 mV to 10V per division in 1% calibrated steps |
Input impedance | 50 Ω |
Features |
|
Internals
Each input channel has a separate 50 ohm attenuator containing, two X10 attenuators, a skin effect correction network, an AC coupling capacitor, a signal pickoff for the input protection network and a switch selecting the calibrator or signal input. In normal operation the calibrator signal to the attenuator is instead connected to ground.
The 11A52 uses custom Tektronix-made chips including the 155-0076-00 (M94 overload detector) and M377 amplifier chip.
The signal output of the attenuator feeds the + input of the M377 amplifier IC through a (blue) 50 ohm transmission line, one per input channel. The cable lengths set a standard delay per plugin. The M377's − input is connected to the ACVS (Analog Control Voltage System) output.
The (differential) display outputs of the two amplifiers are hard-wired in parallel and drive the mainframe’s 50 Ω per side input impedance. The same is true of the trigger outputs of the two amplifiers.
The version of the M377 used in the 11A52 has a 100 Ω output impedance per side so that two of them in parallel create a source impedance of 50 Ω per side.
Each M377 amplifier's nominal common-mode output voltage is zero whether enabled or not. When not enabled, each M377 differential output is exactly zero by design. This fact is used during calibration by the plugin’s firmware to determine the mainframe’s imbalance and compensate for it during normal operation.
In the 11A52, the digital output of the M94 overload detectors (one per channel) are received by the microprocessor. If overload is detected, software running in the microprocessor switches the input relay to remove the signal from the 50 Ω attenuator. This is in contrast to the 485, where the M94 directly controls the input relay.
During the 11A52's self-check, the M94 IC for each channel is tested. An analog switch injects test currents, positive and negative, into the summing junction at the input of each M94. The outputs are checked by the self-check software routine.
Links
Pictures
-
11A52 front
-
-
-
front panel connections
-
-
signal relays, top
-
signal relays, bottom
-
-
-
-
-
-
sample/hold modules
-
-
Input Attenuators Schematic
-
Kernel Schematic
-
Analog Control and Signal Amps
Custom ICs used in the 11A52
Page | Model | Part nos | Description | Designers | Used in |
---|---|---|---|---|---|
155-0076-00 | M94 | 155-0076-00 | input protection and probe logic | John Addis • Wink Gross | 465 • 485 • 7A29 • 7A29P • 11A52 • 11A71 • 11A72 • SCD1000 |
M377 | M377 | 165-2129-03 • 165-2089-06 • 155-2089-05 | amplifier | John Addis | 11A16 • 11A32 • 11A33 • 11A34 • 11A52 • 2245 • 2245A • 2247 • 2247A • 2252 • TDS410 • TDS420 • TDS460 • TDS520D • TDS540D • TDS580D • TDS680C • TDS684C • TDS714L • TDS724D • TDS754D • TDS784D |