DD501: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=DD501 | function=digital delay | class=digital function | image=Tek dd501.JPG | introduced=1975 | discontinued=1990 | | {{TM500 | mfg=Tektronix | type=DD501 | function=digital delay | class=digital function | image=Tek dd501.JPG | introduced=1975 | discontinued=1990 | | ||
designers= |manuals= | designers= |manuals= | ||
* [[Media:070-1818-01.pdf|Tektronix DD501 Manual]] ( | * [[Media:070-1818-01.pdf|Tektronix DD501 Manual]] (OCR) | ||
}} | }} | ||
It provides "delay by events", producing a trigger output pulse after a selectable number (0 − 99,999) of input trigger events. | It provides "delay by events", producing a trigger output pulse after a selectable number (0 − 99,999) of input trigger events. | ||
Line 50: | Line 50: | ||
Tek dd501 on.jpg | Tek dd501 on.jpg | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|DD501}} |
Revision as of 08:01, 19 November 2023
The Tektronix DD501 is a digital delay plug-in for the TM500 system.
It provides "delay by events", producing a trigger output pulse after a selectable number (0 − 99,999) of input trigger events.
Key Specifications
Event count | 0 to 99,999 |
---|---|
Max. count rate | 80 MHz |
Insertion delay | ≤ 30 ns |
Recycle time | ≤ 25 ns |
Min. detectable pulse | ≥ 5 ns |
Input impedance | 1 MΩ // 20 pF |
Input sensitivity | 85 mVp-p up to 80 MHz, selectable + or − slope |
Trigger level | ± 1 V |
Trigger view output | ≥ 0.5 V |
Output | Events pulse width plus 6 ns or less, TTL level (<0.8 V / >2.0 V) into three standard TTL loads |
Links
Documents Referencing DD501
Prices
Year | 1975 | 1980 | 1985 | 1990 |
---|---|---|---|---|
Catalog price | $495 | $850 | $1,385 | $2,295 |
In 2023 Dollars | $2,800 | $3,200 | $3,900 | $5,400 |
Pictures
Components
Some Parts Used in the DD501
- (no results)