T: Difference between revisions
No edit summary |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 4: | Line 4: | ||
|type=Type T | |type=Type T | ||
|summary=Timebase plugin | |summary=Timebase plugin | ||
|image=Tek type t | |image=Tek type t front2.jpeg | ||
|caption=Tektronix Type T timebase | |caption=Tektronix Type T timebase | ||
|introduced=1957 | |introduced=1957 | ||
Line 12: | Line 12: | ||
<!-- * [http://w140.com/tek_fcp/tek_type_t_factory_cal_proc.pdf Tektronix Type T Factory Calibration Procedure (PDF)] --> | <!-- * [http://w140.com/tek_fcp/tek_type_t_factory_cal_proc.pdf Tektronix Type T Factory Calibration Procedure (PDF)] --> | ||
* [[Media:tek_type_t_fcp.pdf|Tektronix Type T Factory Calibration Procedure]] (OCR) | * [[Media:tek_type_t_fcp.pdf|Tektronix Type T Factory Calibration Procedure]] (OCR) | ||
* [[Media:Tek type t mod 104.pdf|Tektronix Type T Mod 104]] ( | * [[Media:Tek type t mod 104.pdf|Tektronix Type T Mod 104]] (OCR) | ||
* [[Media:Tek type t cal outline.pdf|Tektronix Type T Calibration Outline]] (OCR) | * [[Media:Tek type t cal outline.pdf|Tektronix Type T Calibration Outline]] (OCR) | ||
}} | }} | ||
Line 35: | Line 35: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek type t front2.jpeg | |||
Tek type t left2.jpeg | |||
Tek type t right2.jpeg | |||
Tek type t top2.jpeg | |||
Tek type t bottom2.jpeg | |||
Tek type t front.jpg|Front view | Tek type t front.jpg|Front view | ||
Tek_t.jpg|Catalog image | Tek_t.jpg|Catalog image |
Latest revision as of 06:46, 10 March 2024
The Tektronix Type T is a timebase plug-in primarily intended for use in the model 536 X-Y scope. It contains trigger and sweep circuitry. The typical use of a Type T plug-in is as the X-axis plug-in in a 536, to make the 536 behave like a normal oscilloscope instead of an X-Y scope. However, there is no capability for internal triggering – a jumper must be connected from the Vertical Signal Out on the 536 to the External Trig on the Type T.
Plugging a Type T into a vertical slot of a normal 500-series scope produces a raster, and using the scope's Z-axis input this allows a crude video display.
The banana jack on the back of the plugin is to provide retrace blanking when used in the horizontal slot of a 536.
The Type T was introduced in 1957 and dropped after 1972, the same as its primary host, the 536. (Types K, L, and T are tied for longest production life, at 16 years, B, D, and G are next at 15 years.)
Key Specifications
- please add
Pictures
-
-
-
-
-
-
Front view
-
Catalog image
-
front
-
left side
-
top view
-
bottom view
-
read panel
-
top view
-
bottom view
-
Type T as vertical plug-in in 556
-
Trigger schematic
-
Timebase schematic
Some Parts Used in the T
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
6AL5 | 154-016 • 154-0016-00 • 154-0038-00 | Vacuum Tube (Dual Diode) | high-perveance dual diode | 163 • 181 • 190 • 1M1 • 310 • 310A • 315 • 316 • 317 • 3B1 • 3B1S • 3B2 • 3B3 • 3B5 • 502 • 502A • 503 • 511 • 511A • 512 • 516 • 517 • 517A • 524 • 526 • 535 • 535A • 545 • 545A • 549 • 551 • 565 • 570 • 581 • 581A • 585 • 585A • C • T • Telequipment D52 • Telequipment D56 • Telequipment S52 |
6AU8 | 154-0132-00 | Vacuum Tube (Triode/Pentode) | triode-pentode combo | T |
6BQ7A | 154-028 • 154-0028-00 • 157-0022-00 • 157-0003-00 | Vacuum Tube (Dual Triode) | dual triode | 107 • 163 • 181 • 310 • 315 • 316 • 360 • 524 • 531 • 532 • 535 • 536 • 541 • 545 • 570 • T |
6U8 | 154-0033-00 | Vacuum Tube (Triode/Pentode) | triode-pentode combo | 130 • 160 • 163 • 310 • 315 • 316 • 524 • 535 • 545 • T |