SW503: Difference between revisions
Jump to navigation
Jump to search
(New page: * [http://w140.com/smb/SW503_SM.pdf Tektronix SW503 Manual (OCR, PDF)]) |
No edit summary |
||
(24 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
* [ | {{TM500 | ||
|mfg=Tektronix | |||
|type=SW503 | |||
|function=sweep generator | |||
|class=signal generator | |||
|image=Tek SW503 front 1.jpg | |||
|introduced=1976 | |||
|discontinued=1978 | |||
|manuals= | |||
* [[Media:070-2051-00.pdf|SW503 Instruction Manual]] (OCR) | |||
* [[Media:A-3328-1 1976-10.jpg|SW 503 data sheet]], Oct 1976 | |||
}} | |||
{{BeginSpecs}} | |||
{{Spec | Frequency range | 1 to 400 MHz }} | |||
{{Spec | Sweep width | 200 kHz to 400 MHz }} | |||
{{Spec | Sweep time | 10 ms to 100 s, decade steps plus vernier }} | |||
{{Spec | Output | −40 to +10 dBm into 50 Ω }} | |||
{{Spec | Horizontal output | 0.5 V<sub>p-p</sub> }} | |||
{{Spec | Fixed markers | frequency comb with 1, 10, or 50 MHz base frequency }} | |||
{{Spec | Variable marker | 1 to 400 MHz, digital readout on a [[DC502]] Opt.07 counter }} | |||
{{Spec | Features | | |||
* Amplitude control input (0 – 10 V) | |||
* Frequency control input (0 – 10 V) | |||
* Sweep trigger input (10 V pulse ≥1 μs)}} | |||
{{Spec|Options| | |||
* Opt. 01 – 75 Ω output impedance | |||
* Detector – [[118-0070-00]] (50 Ω), [[118-0071-00]] (75 Ω) | |||
}} | |||
{{EndSpecs}} | |||
==Links== | |||
{{Documents|Link=SW503}} | |||
==Rear Interface== | |||
<small> | |||
{| class="wikitable" | |||
|- | |||
! Connector Pin | |||
! Signal | |||
|- | |||
| 28B || Y axis output (common on 28A) | |||
|- | |||
| 27B || X axis output (common on 27A) | |||
|- | |||
| 24B || Trigger input (common on 25B) | |||
|- | |||
| 21B || Amplitude control input (0 – 10 V), common on 22B | |||
|- | |||
| 20B || Frequency control input (0 – 10 V), common on 22B | |||
|- | |||
| 18B || Start Count (0/+5 V; positive pulse to trigger the counter) | |||
|- | |||
| 18A || Gate (0/+5 V; negative gate from counter) | |||
|- | |||
| 17B || Counter Identify (grounded when counter is installed) | |||
|- | |||
| 16B || Phase Lock Logic (+5 V: 100 kHz resolution; 0 V: 10 Hz resolution) | |||
|- | |||
| 15B || CW Mode Logic (+5 V: dot marker function; 0 V: normal counter function) | |||
|- | |||
| 14B || Sweep Generator Identify (grounded when SW503 is installed) | |||
|- | |||
|} | |||
</small> | |||
==Pictures== | |||
'''External''' | |||
<gallery> | |||
Tek SW503 front 1.jpg | |||
Tek sw503 dc502 sg504 dc508a mr501 tm515.png|SW503 in [[TM515]] with other TM500 gear | |||
Tek sw503 front2.jpg | |||
Tek sw503 front3.jpg | |||
</gallery> | |||
'''SW503 Opt.1''' | |||
<gallery> | |||
Tek sw503 opt1 1.jpg | |||
Tek sw503 opt1 2.jpg | |||
Tek sw503 opt1 3.jpg | |||
Tek sw503 opt1 4.jpg | |||
Tek sw503 opt1 5.jpg | |||
</gallery> | |||
'''SW503B''' | |||
<gallery> | |||
SW503B.jpg | SW503B catalog picture | |||
</gallery> | |||
'''Internal''' | |||
<gallery> | |||
Tek SW503 left.jpg | |||
Tek SW503 right.jpg | |||
</gallery> | |||
==Components== | |||
{{Parts|SW503}} |
Latest revision as of 04:48, 5 October 2024
The Tektronix SW503 is a sweep generator plug-in for the TM500 system.
Key Specifications
Frequency range | 1 to 400 MHz |
---|---|
Sweep width | 200 kHz to 400 MHz |
Sweep time | 10 ms to 100 s, decade steps plus vernier |
Output | −40 to +10 dBm into 50 Ω |
Horizontal output | 0.5 Vp-p |
Fixed markers | frequency comb with 1, 10, or 50 MHz base frequency |
Variable marker | 1 to 400 MHz, digital readout on a DC502 Opt.07 counter |
Features |
|
Options |
|
Links
Documents Referencing SW503
Rear Interface
Connector Pin | Signal |
---|---|
28B | Y axis output (common on 28A) |
27B | X axis output (common on 27A) |
24B | Trigger input (common on 25B) |
21B | Amplitude control input (0 – 10 V), common on 22B |
20B | Frequency control input (0 – 10 V), common on 22B |
18B | Start Count (0/+5 V; positive pulse to trigger the counter) |
18A | Gate (0/+5 V; negative gate from counter) |
17B | Counter Identify (grounded when counter is installed) |
16B | Phase Lock Logic (+5 V: 100 kHz resolution; 0 V: 10 Hz resolution) |
15B | CW Mode Logic (+5 V: dot marker function; 0 V: normal counter function) |
14B | Sweep Generator Identify (grounded when SW503 is installed) |
Pictures
External
-
-
SW503 in TM515 with other TM500 gear
-
-
SW503 Opt.1
SW503B
-
SW503B catalog picture
Internal
Components
Some Parts Used in the SW503
- (no results)