SW503: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 9: Line 9:
|manuals=
|manuals=
* [[Media:070-2051-00.pdf|SW503 Instruction Manual]] (OCR)
* [[Media:070-2051-00.pdf|SW503 Instruction Manual]] (OCR)
* [[Media:A-3328-1 1976-10.jpg|SW 503 data sheet]], Oct 1976
}}
}}
{{BeginSpecs}}
{{BeginSpecs}}
Line 23: Line 24:
* Sweep trigger input (10 V pulse ≥1 μs)}}
* Sweep trigger input (10 V pulse ≥1 μs)}}
{{Spec|Options|
{{Spec|Options|
* Opt. 01 – 75 Ω output impedance}}
* Opt. 01 – 75 Ω output impedance
* Detector – [[118-0070-00]] (50 Ω), [[118-0071-00]] (75 Ω)
}}
{{EndSpecs}}
{{EndSpecs}}



Latest revision as of 04:48, 5 October 2024

Tektronix SW503
sweep generator
Tektronix SW503

Produced from 1976 to 1978

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix SW503 is a sweep generator plug-in for the TM500 system.

Key Specifications

Frequency range 1 to 400 MHz
Sweep width 200 kHz to 400 MHz
Sweep time 10 ms to 100 s, decade steps plus vernier
Output −40 to +10 dBm into 50 Ω
Horizontal output 0.5 Vp-p
Fixed markers frequency comb with 1, 10, or 50 MHz base frequency
Variable marker 1 to 400 MHz, digital readout on a DC502 Opt.07 counter
Features
  • Amplitude control input (0 – 10 V)
  • Frequency control input (0 – 10 V)
  • Sweep trigger input (10 V pulse ≥1 μs)
Options

Links

Documents Referencing SW503

Document Class Title Authors Year Links
070-2088-01.pdf Book TM500 Series Rear Interface Data Book 1976
Tekscope 1976 V8 N1.pdf Article New Products 1976
070-2088-04.pdf Book TM500 Series Rear Interface Data Book 1985

Rear Interface

Connector Pin Signal
28B Y axis output (common on 28A)
27B X axis output (common on 27A)
24B Trigger input (common on 25B)
21B Amplitude control input (0 – 10 V), common on 22B
20B Frequency control input (0 – 10 V), common on 22B
18B Start Count (0/+5 V; positive pulse to trigger the counter)
18A Gate (0/+5 V; negative gate from counter)
17B Counter Identify (grounded when counter is installed)
16B Phase Lock Logic (+5 V: 100 kHz resolution; 0 V: 10 Hz resolution)
15B CW Mode Logic (+5 V: dot marker function; 0 V: normal counter function)
14B Sweep Generator Identify (grounded when SW503 is installed)

Pictures

External

SW503 Opt.1

SW503B

Internal


Components

Some Parts Used in the SW503

(no results)