User:Peter: Difference between revisions
No edit summary |
No edit summary |
||
Line 58: | Line 58: | ||
Tek-017-067.jpg | [[109|017-067]] | Tek-017-067.jpg | [[109|017-067]] | ||
Tek134-front-2.jpg | [[134]] | Tek134-front-2.jpg | [[134]] | ||
</gallery> | P6022+term.jpg | [[P6022]] | ||
</gallery> | |||
===Screen shots=== | ===Screen shots=== | ||
Line 118: | Line 119: | ||
P6021-6022-1000hz.jpg | P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mA<sub>p-p</sub>, 1 kHz | P6021-6022-1000hz.jpg | P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mA<sub>p-p</sub>, 1 kHz | ||
P6021-6022-10000hz.jpg | P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mA<sub>p-p</sub>, 10 kHz | P6021-6022-10000hz.jpg | P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mA<sub>p-p</sub>, 10 kHz | ||
P6021-bat41-1.jpg | Measuring diode reverse recovery | |||
P6021-bat41-2.jpg | BAT41 diode reverse recovery, 20 mA/Div | |||
</gallery> | </gallery> |
Revision as of 06:05, 26 October 2016
Scopes
Plugins
Probes and other gear
Screen shots
-
Faster-than-light beam on 7104? Using a 067-0587-02 calibration fixture at maximum amplitude produces this trace spanning 1.2 Div horizontally at 200 ps/Div and 8 Div vertically. Trace length is (1.2² + 8²)½ × 8.5 mm = 68.8 mm, travelled in 1.2 × 200 ps = 240 ps. Apparent speed is therefore 68.8×10-3 / 240×10-12 m/s or 2.86×108 m/s. Very near miss ...
-
Rise time measurement. 150 ps risetime pulse from 067-0587-02 at 100 Hz repetition rate. Measured 240 ps (corrected for 150 ps fixture rise time: 190 ns = 1.8 GHz)
-
Rise time measurement as before, 1000 Hz repetition rate at same brightness settings.
-
7104 recording a single shot pulse (from 067-0587-02) at 200 ps/Div. Camera: Nikon D7000, 50 mm f/1.4, ISO 3200, 1/2 s. CRT filter not removed.
-
7104 recording 1 GHz sine, single shot at 500 ps/Div. Camera: Nikon D7000, 50 mm f/1.4, ISO 3200, 1/2 s. CRT filter not removed. CRT amplification loss is evident around the center line.
-
BC337 on 7CT1N
-
P6202 rise time
-
P6202 rise time
-
P6230 Rise time without ground lead: 9.2 * 20 ps = 184 ps (equiv. to 1.9 GHz bandwidth)
-
P6230 Rise time - Effect of using the "low inductance" ground lead - rise time 400 ps, bandwidth 875 MHz
-
P6230 Rise time - Using the 250 mm alligator ground lead - severe pulse distortion, rise time ~3 ns (115 MHz)!
-
A 7B92A (B098xxx) displaying a 1.01 GHz sine in HF Sync mode (7904 mainframe, 7A19 amplifier)
-
A 7B92A (B098xxx) triggering a 974 MHz sine applied via 067-0587-02 calibration fixture
-
Classic readout board diagnostic display
-
15 μVp-ptriangle wave measured through 7A22. Using variable-persistence storage mode on a 7613 for noise filtering.
-
Tektronix 067-0587-02, gain mode, in horizontal slot
-
Tektronix 067-0587-02, gain mode, in vertical slot
-
7D14 screen picture - 500 MHz signal (7A19, 7B92A, 7904)
-
7B85 used for rise time measurement
-
7B85 used for rise time measurement
-
7B85 used for pulse width measurement
-
7B85 used for pulse period measurement
-
7B85 used for pulse period measurement
-
7S11/7T11, 1 GHz sine, smooth mode, on variable-persistence storage scope (7613)
-
7S11/7T11, 1 GHz sine, smooth mode
-
7S11/7T11, 1 GHz sine, normal mode
-
7S11/S-4 and 7T11A displaying 1 GHz sine
-
7S12 as a sampler displaying a 1 GHz signal (hi-res mode / storage)
-
7S12 as a sampler displaying a 1 GHz signal (hi-res mode / storage)
-
7S12 as a sampler displaying a 1 GHz signal (normal mode / non-storage)
-
7S12 displaying the incident pulse from an S-52 (nom. < 25 ps) through an S-6 head (nom. < 30 ps)
-
7S12/S-6/S-52 "Self Portrait" - pulse reflected on S-6 "through" path (approx. 120 ps one way)
-
Full pulse pattern of a 7S12/S-52 in real time (top trace) and sampled (bottom trace) shown simultaneously on 7844. 7S12 trace at slowest possible sweep.
-
S-52 pulse in real time (top trace) and sampled (bottom trace) shown simultaneously on 7844. Approximately equal time scales.
-
sub-millivolt triangle signal displayed through 7A22, BW=1 kHz
-
sub-millivolt triangle signal displayed through 7A22, BW=10 kHz
-
sub-millivolt triangle signal displayed through 7A22, BW=100 kHz
-
sub-millivolt triangle signal through 7A22, BW=1 MHz
-
P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mAp-p, 100 Hz
-
P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mAp-p, 1 kHz
-
P6022 / passive term. @ 10 mA/Div (top) vs. P6021+134 (bottom), sawtooth @ 100 mAp-p, 10 kHz
-
Measuring diode reverse recovery
-
BAT41 diode reverse recovery, 20 mA/Div