{{TM500 | mfg=Tektronix | type=DM501 | function=4½ digit True RMS multimeter | class=multimeter | image=DM501 front.jpg | introduced=1978 | discontinued=1984 |
{{TM500 | mfg=Tektronix | type=DM501 | function=4½ digit multimeter | class=multimeter | image=Tek DM501.JPG | introduced=1972 | discontinued=1980 |
manuals=
designers= |manuals=
* [http://w140.com/tek_dm501.pdf Tektronix DM501 Manual (PDF)]
* [[Media:070-1446-00.pdf|Tektronix DM501 Manual]]
* [http://w140.com/tek_dm501a_070-2749-00_with_schematics.pdf Tektronix DM501A Manual (PDF, complete with schematics)]
* [http://w140.com/tek_dm501a.pdf Tektronix DM501A Manual (PDF, no schematics)]
* [http://w140.com/tekwiki/images/9/96/DM501A_schematics.pdf Tektronix DM501A Schematics (PDF)]
}}
}}
(See [[DM501A]] for the significantly different successor model.)


It also has a temperature input, requiring the [[P6058]] or [[P6430]] temperature probe (DM501A: [[P6601]] PT-100 probe).
It also has a temperature input, requiring the [[P6058]] temperature probe with a 4-pin [[LEMO S-series connector]].  The manual states that ''certain NPN transistors such as a 2N2484 may be used as temperature sensors in place of the probe with little or no selection of the transistor''.
 
The '''DM501 MOD718D''' variant replaced the temperature range with a 200 mV input range providing 10 μV resolution (see [[Media:Physical Measurements Handbook.pdf | Physical Measurements Handbook]]).


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | DC V ranges | 200 mV, 2 V, 20 V, 200 V, 1000 V }}
{{Spec | DC Voltage | 2 V<sub>DC</sub> to 200 V<sub>DC</sub> in decade ranges (0.1% + 0.01% FS), 1000 V<sub>DC</sub> (0.1% + 0.02% FS); Input resistance 10 MΩ, CMRR >100 dB at DC, 80 dB at 60 Hz (1 kΩ unbal.), NMRR ≥30 dB at 60 Hz + 20 dB/decade }}
{{Spec | DC V accuracy | 0.05% of reading + 0.01% FS in 2 V to 200 V ranges @ +18 °C to +28 °C }}
{{Spec | AC Voltage | 2 V<sub>DC</sub> to 200 V<sub>AC</sub> in decade ranges, and 500 V<sub>AC</sub> (0.7% + 0.01% FS for sine inputs only); Input impedance 10 MΩ // ≤70 pF, CMRR unspecified }}
{{Spec | DC V input resistance | 10 MΩ }}
{{Spec | DC Current | 2 mA to 2 A in decade ranges, 0.2% + 0.05% FS }}
{{Spec | AC V ranges | 200 mV, 2 V, 20 V, 200 V, 500 V }}
{{Spec | AC Current | 2 mA to 2 A in decade ranges, 0.6% + 0.05% FS (for 40 Hz to 1 kHz sine) }}
{{Spec | AC V accuracy | 0.6% of reading + 0.05% FS in 0.2 V to 200 V ranges, 40 Hz to 10 kHz @ +18 °C to +28 °C }}
{{Spec | Ohms | 2 kΩ to 20 MΩ in decade ranges, current 1 mA to 0.1 μA respectively; 0.3% (20 MΩ: 0.5%) + 0.01% FS }}
{{Spec | AC V input resistance | 10 MΩ // 160 pF }}
{{Spec | Temperature | –55°C to +125°C (±1.5°C), +125°C to 150°C (±2.5°C) }}
{{Spec | dB ranges | -40, -20, 0, +20, +40 dB }}
{{Spec | Ω ranges | 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20  MΩ }}
{{Spec | Ω accuracy | 0.15% of reading + 0.015% FS, 200 Ω to 2 MΩ ranges @ +18 °C to +28 °C }}
{{Spec | DC A ranges | 200 μA, 2 mA, 20 mA, 200 mA, 2 A }}
{{Spec | DC A accuracy | 0.2% of reading + 0.015% FS @ +18 °C to +28 °C }}
{{Spec | AC A ranges | 200 μA, 2 mA, 20 mA, 200 mA, 2 A }}
{{Spec | AC A accuracy | 0.6% of reading + 0.05% FS, 20 Hz to 10 kHz @ +18 °C to +28 °C }}
{{Spec | Temperature range | -62 °C to +240 °C }}
{{Spec | Temperature accuracy | ±2 °C from -62 °C to +150 °C with probe calibrated to instrument, @ +18 °C to +28 °C ambient }}
{{EndSpecs}}
{{EndSpecs}}
===Options===
* Option 1: Ordering without P6058 Temp Probe
* Option 2: Without Temp Capability and Probe (visible by no ''Temp Out'' at the Front)
==Links==
* [https://www.youtube.com/watch?v=GaSy1MezeNs                                  Tektronix DM501 Check in and Calibration] by Zenwizard Studios @ YouTube
{{Documents|Link=DM501}}
==Rear interface==
The DM501 has a rear input, selectable by a front-panel button, on B28 (Hi) / A29 (Lo), and digit-serial BCD outputs (TTL), see below.
The manual does not specify a limit to the input voltage on the rear interface but since this uses card-edge pins adjacent to logic output pins, sticking to the the DM501A specification (200 V peak / 100 V RMS) appears prudent.
==Internals==
The DM501 is precise to 4½ digits, but not accurate to 4½ digits. The combination of an ADC built from opamps and discretes combined with a noisy high-frequency isolated power supply make for barely achievable 3½ digit accuracy over all ranges. Every TM500 DVM after the 501 (including the [[DM501A]], the [[DM502]], and so on) used integrated A-to-D converters and a mains-frequency isolated power supply.


==Pictures==
==Pictures==


<gallery>
<gallery>
DM501 front.jpg | DM501
DM501 front.jpg     | DM501
Tek dm501a on.jpg|DM501A
DM501_open_left.jpg | DM501 open left side
Tek dm501a 1.jpg | DM501A
Tek_DM501_integrator_pcb-comp_side.jpg | DM501 integrator board
Tek dm501a ext1.jpg|DM501A on an extension cable
DM501 1977.jpg     | Two late DM501s with modified integrator boards
Tek dm501a dark.jpg|DM501
Tek_DM501_integrator_pcb-solder_side.jpg | DM501 integrator board solder side
DM501 rear interface.png | DM501 rear interface


</gallery>
</gallery>


* [http://w140.com/tekwiki/images/d/d5/Siliconix_LD120_and_LD121A_datasheets.pdf Siliconix LD120 and LD121A datasheets]
==Components==
{{Parts|DM501}}

Revision as of 15:56, 2 July 2024

Tektronix DM501
4½ digit multimeter
Tektronix DM501

Produced from 1972 to 1980

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix DM501 is a 4½ digit multimeter plug-in for the TM500 system.

(See DM501A for the significantly different successor model.)

It also has a temperature input, requiring the P6058 temperature probe with a 4-pin LEMO S-series connector. The manual states that certain NPN transistors such as a 2N2484 may be used as temperature sensors in place of the probe with little or no selection of the transistor.

The DM501 MOD718D variant replaced the temperature range with a 200 mV input range providing 10 μV resolution (see Physical Measurements Handbook).

Key Specifications

DC Voltage 2 VDC to 200 VDC in decade ranges (0.1% + 0.01% FS), 1000 VDC (0.1% + 0.02% FS); Input resistance 10 MΩ, CMRR >100 dB at DC, 80 dB at 60 Hz (1 kΩ unbal.), NMRR ≥30 dB at 60 Hz + 20 dB/decade
AC Voltage 2 VDC to 200 VAC in decade ranges, and 500 VAC (0.7% + 0.01% FS for sine inputs only); Input impedance 10 MΩ // ≤70 pF, CMRR unspecified
DC Current 2 mA to 2 A in decade ranges, 0.2% + 0.05% FS
AC Current 2 mA to 2 A in decade ranges, 0.6% + 0.05% FS (for 40 Hz to 1 kHz sine)
Ohms 2 kΩ to 20 MΩ in decade ranges, current 1 mA to 0.1 μA respectively; 0.3% (20 MΩ: 0.5%) + 0.01% FS
Temperature –55°C to +125°C (±1.5°C), +125°C to 150°C (±2.5°C)

Options

  • Option 1: Ordering without P6058 Temp Probe
  • Option 2: Without Temp Capability and Probe (visible by no Temp Out at the Front)

Links

Documents Referencing DM501

Document Class Title Authors Year Links
Tekscope 1974 V6 N3.pdf Article The 31/53 Calculator-based Measurement Instrumentation Package John Mulvey 1974
070-2088-00.pdf Book TM500 Series Rear Interface Data Book 1975
070-2088-01.pdf Book TM500 Series Rear Interface Data Book 1976
070-2088-04.pdf Book TM500 Series Rear Interface Data Book 1985

Rear interface

The DM501 has a rear input, selectable by a front-panel button, on B28 (Hi) / A29 (Lo), and digit-serial BCD outputs (TTL), see below. The manual does not specify a limit to the input voltage on the rear interface but since this uses card-edge pins adjacent to logic output pins, sticking to the the DM501A specification (200 V peak / 100 V RMS) appears prudent.

Internals

The DM501 is precise to 4½ digits, but not accurate to 4½ digits. The combination of an ADC built from opamps and discretes combined with a noisy high-frequency isolated power supply make for barely achievable 3½ digit accuracy over all ranges. Every TM500 DVM after the 501 (including the DM501A, the DM502, and so on) used integrated A-to-D converters and a mains-frequency isolated power supply.

Pictures

Components

Some Parts Used in the DM501

Part Part Number(s) Class Description Used in
307-1015-00 307-1015-00 Discrete component resistor network DM501
Fairchild 3814 156-0306-00 Monolithic integrated circuit 4½ digit dual-slope DVM controller 7A13 7L13 7L18 DM501