DM501A: Difference between revisions
Jump to navigation
Jump to search
(Redirected page to DM501) |
No edit summary |
||
(11 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=DM501A | function=4½ digit True RMS multimeter | class=multimeter | image=Tek dm501a on.jpg | introduced=1980 | discontinued=1984 | | |||
[[ | designers=Bill Mark |manuals= | ||
[[ | * [[Media:070-2749-00.pdf|Tektronix DM501A Manual]] (with schematics) | ||
* [[Media:070-2749-00 no schematics.pdf|Tektronix DM501A Manual]] (no schematics) | |||
* [[Media:DM501A_schematics.pdf|Tektronix DM501A Schematics]] | |||
}} | |||
It replaced the [[DM501]] (which suffered from accuracy limitations) in 1980. It also has a temperature input, requiring the [[P6601]] PT-100 probe with a 2-pin [[LEMO S-series connector]]. | |||
The DM501A was designed by [[Bill Mark]]. | |||
{{BeginSpecs}} | |||
{{Spec | DC Voltage | 200 mV<sub>DC</sub> to 1000 V<sub>DC</sub> in decade ranges; 0.05% + 0.01% (200 mV: 0.015% / 1000 V: 0.02%) FS }} | |||
{{Spec | DC Input characteristics | Input resistance 10 MΩ; CMRR >100 dB at DC, 80 dB at 50 and 60 Hz (1 kΩ unbal.), NMRR 60 dB at 50 or 60 Hz }} | |||
{{Spec | AC Voltage | 200 mV<sub>DC</sub> to 500 V<sub>AC</sub> in decade ranges; 0.6% + 0.05% (500 V: 0.2%) FS; True RMS; }} | |||
{{Spec | AC Input characteristics | Input impedance 10 MΩ // ≤160 pF; CMRR 60 dB at 50 or 60 Hz (1 kΩ unbal.)}} | |||
{{Spec | DC Current | 200 μA to 2 A in decade ranges; 0.2% + 0.015% FS }} | |||
{{Spec | AC Current | 200 μA to 2 A in decade ranges; 0.6% + 0.05% FS (20 Hz-10 kHz sine >5% FS) }} | |||
{{Spec | Ohms | 200 Ω to 20 MΩ in decade range; current 1 mA, 1 mA, 100 μA – 0.1 μA respectively; 0.15% (20 MΩ: 0.5%) + 0.015% FS }} | |||
{{Spec | Temperature | –62°C to +240°C (+0/-6°C or +2/-8°C any probe, uncal.); +150°C, ±2°C cal. probe, ±4°C uncal. probe; +150°C to +240°C, +0/-6°C or +2/-8°C any probe, uncal. }} | |||
{{EndSpecs}} | |||
==Links== | |||
{{Documents|Link=DM501A}} | |||
==Rear interface== | |||
The DM501A has a rear input, selectable by a front-panel button, on B28 (Hi) / A29 (Lo). Unlike the DM501 (non-A), it has no digital outputs. | |||
Input voltage on the rear interface is limited to 200 V peak / 100 V RMS. | |||
==Pictures== | |||
<gallery> | |||
Tek dm501a on.jpg|DM501A | |||
Tek dm501a 1.jpg | DM501A | |||
Tek dm501a ext1.jpg|DM501A Option 2 (no temperature range) on an extension cable | |||
Tek dm501a dark.jpg|DM501A | |||
DM501A_rear_con.JPG|DM501A rear connector | |||
Tek-DM501A-RHS.jpg| DM501A RHS | |||
TEK-DM501A-LHS.jpg| DM501A LHS | |||
Tek-DM501A-LHS-removed shielding.jpg| DM501A LHS, shielding removed | |||
</gallery> | |||
==Components== | |||
{{Parts|DM501A}} |
Latest revision as of 05:32, 1 December 2023
The Tektronix DM501A is a 4½ digit True RMS multimeter plug-in for the TM500 system.
It replaced the DM501 (which suffered from accuracy limitations) in 1980. It also has a temperature input, requiring the P6601 PT-100 probe with a 2-pin LEMO S-series connector.
The DM501A was designed by Bill Mark.
Key Specifications
DC Voltage | 200 mVDC to 1000 VDC in decade ranges; 0.05% + 0.01% (200 mV: 0.015% / 1000 V: 0.02%) FS |
---|---|
DC Input characteristics | Input resistance 10 MΩ; CMRR >100 dB at DC, 80 dB at 50 and 60 Hz (1 kΩ unbal.), NMRR 60 dB at 50 or 60 Hz |
AC Voltage | 200 mVDC to 500 VAC in decade ranges; 0.6% + 0.05% (500 V: 0.2%) FS; True RMS; |
AC Input characteristics | Input impedance 10 MΩ // ≤160 pF; CMRR 60 dB at 50 or 60 Hz (1 kΩ unbal.) |
DC Current | 200 μA to 2 A in decade ranges; 0.2% + 0.015% FS |
AC Current | 200 μA to 2 A in decade ranges; 0.6% + 0.05% FS (20 Hz-10 kHz sine >5% FS) |
Ohms | 200 Ω to 20 MΩ in decade range; current 1 mA, 1 mA, 100 μA – 0.1 μA respectively; 0.15% (20 MΩ: 0.5%) + 0.015% FS |
Temperature | –62°C to +240°C (+0/-6°C or +2/-8°C any probe, uncal.); +150°C, ±2°C cal. probe, ±4°C uncal. probe; +150°C to +240°C, +0/-6°C or +2/-8°C any probe, uncal. |
Links
Documents Referencing DM501A
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1979 V11 N3.pdf | Article | A New DMM Family for the TM 500 Series | Bill Mark | 1979 | DM501A • DM502A • DM505 • P6601 |
070-2088-04.pdf | Book | TM500 Series Rear Interface Data Book | 1985 | AA501 • AF501 • AM501 • AM502 • AM503 • AM511 • DC501 • DC502 • DC503 • DC503A • DC504 • DC505 • DC505A • DC508 • DC508A • DC509 • DC510 • DC5009 • DC5010 • DD501 • DL502 • DM501 • DM501A • DM502 • DM502A • DM505 • DM5010 • FG501 • FG501A • FG502 • FG503 • FG504 • FG507 • FG5010 • LA501 • LA501W • WR501 • MR501 • PG501 • PG502 • PG505 • PG506 • PG507 • PG508 • PS501 • PS502 • PS503 • PS503A • PS505 • PS5010 • RG501 • SC501 • SC502 • SC503 • SC504 • SG502 • SG503 • SG504 • SG505 • SW503 • TG501 • TR501 • TR502 • MI5010 • MX5010 • SI5010 |
Rear interface
The DM501A has a rear input, selectable by a front-panel button, on B28 (Hi) / A29 (Lo). Unlike the DM501 (non-A), it has no digital outputs. Input voltage on the rear interface is limited to 200 V peak / 100 V RMS.
Pictures
-
DM501A
-
DM501A
-
DM501A Option 2 (no temperature range) on an extension cable
-
DM501A
-
DM501A rear connector
-
DM501A RHS
-
DM501A LHS
-
DM501A LHS, shielding removed
Components
Some Parts Used in the DM501A
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
AD536 | 156-1259-00 | Monolithic integrated circuit | RMS/DC converter | DM501A • DM502A • DM5010 • Keithley 177 • Keithley 179 • Keithley 195A |
Siliconix LD120 | 156-1306-00 | Monolithic integrated circuit | 4½ digit integrating ADC (analog section) | DM501A • DM5010 |
Siliconix LD121A | 156-1305-00 | Monolithic integrated circuit | 4½ digit integrating ADC (digital section) | 7A13 • DM501A |