DM502A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by one other user not shown)
Line 29: Line 29:
* DM502A Autoranging DMM, video by by IMSAI Guy @ YouTube: [https://www.youtube.com/watch?v=J5hw4zyLrks Part 1] / [https://www.youtube.com/watch?v=J5hw4zyLrks Part 2]
* DM502A Autoranging DMM, video by by IMSAI Guy @ YouTube: [https://www.youtube.com/watch?v=J5hw4zyLrks Part 1] / [https://www.youtube.com/watch?v=J5hw4zyLrks Part 2]
{{Documents|Link=DM502A}}
{{Documents|Link=DM502A}}
{{PatentLinks|DM502A}}


==Internals==
==Internals==
Line 42: Line 43:
Tek dm502a right internal.jpg|DM502A right internal
Tek dm502a right internal.jpg|DM502A right internal
Tek-DM502A-rear-interface.jpg|DM502A rear interface
Tek-DM502A-rear-interface.jpg|DM502A rear interface
DM502A_3.jpeg
DM502A_2.jpeg
DM502A_1.jpeg
</gallery>
</gallery>



Latest revision as of 05:23, 6 October 2024

Tektronix DM502A
3½ digit TRMS digital multimeter
Tektronix DM502A

Produced from 1980 to 1988

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix DM502A is a 3½ digit TRMS digital multimeter plug-in for the TM500 system.

It superseded the DM502 predecessor in 1980.

Compared to the DM502, the DM502A adds autoranging, a True RMS converter, and offset circuits to read dB directly in all ranges. The temperature input is for a PT-100 temperature probe (P6601).

An "Option 2" instrument deletes the temperature measurement function, P6601 temperature probe, and all internal circuits associated with this function.

The rear interface of DM502A is limited compared to the DM502 in that it has no current input and no digital output, the latter having been obsoleted by TM5000 GPIB based instruments.

The 2 kΩ measurement range (+HI in DM502A) can be used for diode testing, since a current source of 1 mA is active and the reading corresponds to the (forward) voltage drop of the diode in Volts. The voltage can rise to a maximum of 10 Volts. A second voltmeter is needed to measure the voltage if 2 V are exceeded.

The DM502A has an Int/Ext switch that allows a voltage input via the rear interface to be selected.

Key Specifications

Voltage ranges 200 mV to 200 V in decade steps; 1 kV (DC) / 500 V (AC) top range
Input impedance 10 MΩ
Current ranges 200 μA to 2 A in decade steps
Resistance ranges 200 Ω to 20 MΩ in decade steps

Links

Documents Referencing DM502A

Document Class Title Authors Year Links
Tekscope 1979 V11 N2.pdf Article New Products 1979
Tekscope 1979 V11 N3.pdf Article A New DMM Family for the TM 500 Series Bill Mark 1979
070-2088-04.pdf Book TM500 Series Rear Interface Data Book 1985

Internals

The DM502A circuit is built around a Siliconix LD110/111A DMM chipset. The entire circuit is supplied from one of the mainframe's 25 VAC windings through a main-frequency isolation transformer with a 25 V primary winding and 7815/7915/7805 regulators. The 25 VAC input is the only mainframe connection, so the DM502A could easily be used outside a TM500 mainframe as well.

Pictures

Components

Some Parts Used in the DM502A

Part Part Number(s) Class Description Used in
120-1243-00 120-1243-00 Discrete component transformer DM502A
AD536 156-1259-00 Monolithic integrated circuit RMS/DC converter DM501A DM502A DM5010 Keithley 177 Keithley 179 Keithley 195A