B: Difference between revisions
No edit summary |
No edit summary |
||
(14 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | ||
|manufacturer=Tektronix | |||
summary=20 MHz amplifier plug-in | | |series=500-series scopes | ||
image=Tek | |type=Type B | ||
caption=Tektronix Type B | |summary=20 MHz amplifier plug-in | ||
|image=Tek type 53 54b.jpeg | |||
introduced= | |caption=Tektronix Type B | ||
discontinued=1971 | | |introduced=1954 | ||
manuals= | |discontinued=1971 | ||
|manuals= | |||
* [[Media:070-219.pdf|Tektronix Type B manual 070-219]] | |||
* [[Media:tek_type_b_fcp.pdf|Tektronix Type B Factory Calibration Procedure]] (bad-OCR) | |||
* [[Media:070-219.pdf|Tektronix Type B manual | |||
* [[Media:tek_type_b_fcp.pdf|Tektronix Type B Factory Calibration Procedure ( | |||
}} | }} | ||
The '''Tektronix Type B''' is a plug-in for [[500-series scopes]]. | The '''Tektronix Type B''' is a plug-in for [[500-series scopes]]. | ||
It is identical to [[A|Type A]], with the addition of a ×10-gain | It is identical to [[A|Type A]], with the addition of a ×10-gain AC amplifier which can be switched in to extend the vertical sensitivity from 50 mV/div to 5 mV/div. | ||
AC amplifier which can be switched in to extend the vertical | |||
sensitivity from 50 mV/div to 5 mV/div. | |||
Like | Like Type A, Type B has its roots in the [[introduced in 1954|1954]] introduction of the [[531]] and [[535]], as the five-tube Type 53B, | ||
introduction of the [[531]] and [[535]], as the Type 53B, | with 1x bandwidth of DC to 10MHz (limited by the mainframe) and 10x-AC bandwidth of 2 Hz to 9 MHz. | ||
with 10x-AC bandwidth of 2 Hz to 9 MHz. | |||
In 1956, it was replaced by the Type 53/54B with DC−20 MHz | In 1956, at serial number 3301, it was replaced by the six-tube Type 53/54B with DC−20 MHz | ||
or 2 Hz−12 MHz bandwidth in the [[541]] and [[545]]. | or 2 Hz−12 MHz bandwidth in the [[541]] and [[545]]. | ||
In 1959, | In 1959, Type 53/54B was renamed Type B, and it remained available through 1970. | ||
and it | |||
The military version is known as the '''AM-1841/USM''', | The military version is known as the '''AM-1841/USM''', which is the same as a 53/54B MOD601. | ||
[[K]], [[L]], and [[T]] are tied for longest production life, at 16 years. | [[K]], [[L]], and [[T]] are tied for longest production life, at 16 years. | ||
Line 40: | Line 31: | ||
[[Lavoie Laboratories]] produced an unauthorized clone, the [[Lavoie LA-265-B]]. | [[Lavoie Laboratories]] produced an unauthorized clone, the [[Lavoie LA-265-B]]. | ||
{{MissingSpecs}} | |||
==Links== | |||
{{Documents|Link=B}} | |||
==Pictures== | ==Pictures== | ||
===53B=== | |||
<gallery> | |||
Tek 53b 1.jpg | |||
Tek 53b 2.jpg | |||
Tek 53b 3.jpg | |||
</gallery> | |||
===53/54B=== | ===53/54B=== | ||
Line 77: | Line 76: | ||
Tek am1841 6.jpg | Tek am1841 6.jpg | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|B}} | |||
[[Category:500 series plugins]] | [[Category:500 series plugins]] |
Latest revision as of 10:45, 1 July 2024
The Tektronix Type B is a plug-in for 500-series scopes.
It is identical to Type A, with the addition of a ×10-gain AC amplifier which can be switched in to extend the vertical sensitivity from 50 mV/div to 5 mV/div.
Like Type A, Type B has its roots in the 1954 introduction of the 531 and 535, as the five-tube Type 53B, with 1x bandwidth of DC to 10MHz (limited by the mainframe) and 10x-AC bandwidth of 2 Hz to 9 MHz.
In 1956, at serial number 3301, it was replaced by the six-tube Type 53/54B with DC−20 MHz or 2 Hz−12 MHz bandwidth in the 541 and 545.
In 1959, Type 53/54B was renamed Type B, and it remained available through 1970.
The military version is known as the AM-1841/USM, which is the same as a 53/54B MOD601.
K, L, and T are tied for longest production life, at 16 years. B, D, and G are next at 15 years.
Lavoie Laboratories produced an unauthorized clone, the Lavoie LA-265-B.
Key Specifications
- please add
Links
Documents Referencing B
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
IBM 223-6725-2.pdf | Application Note | Tektronix oscilloscopes (IBM Customer Engineering Manual) | 1960 | 310 • 310A • 531 • 531A • 535 • 535A • 545A • B • C • CA • D • G |
Pictures
53B
53/54B
-
Type 53/54B
-
-
-
-
Type B
-
Type B
-
-
-
-
-
-
-
Schematic of early version
-
Schematic of late version
AM-1841/USM
Components
Some Parts Used in the B
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
12AT7 | 154-0039-00 | Vacuum Tube (Dual Triode) | dual high-gain triode | 161 • 180 • 310 • 310A • 315 • 316 • 360 • 502 • 502A • 511A • 512 • 513 • 513D • 514 • 514AD • 514D • 516 • 524 • 529 • RM529 • 544 • 546 • 547 • 556 • 565 • 570 • 3A2 • 75 • 3A75 • 1M1 • A • B • C • G • H • K • L • ML • M • N • K • R • S • Z • Keithley 610B |
12AU6 | 154-0040-00 | Vacuum Tube (Pentode) | RF pentode | 81 • 112 • 1L10 • 1L20 • 1L60 • 3L10 • 512 • 556 • 575 • 545 • 547 • 549 • 581 • 585 • A • B • C • G • K • H • L • ML • M • N • O • R • S • Z |
5654 | 154-0206-00 • 154-0084-00 | Vacuum Tube (Pentode) | RF pentode | B • L • ML |
6AK5 | 154-0014-00 • 154-0206-00 • 154-0084-00 | Vacuum Tube (Pentode) | RF pentode | B • C • CA • G • K • L • ML • S • Z • 517 • 517A • 524 |
6DJ8 | 154-0187-00 • 154-0305-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 111 • 132 • 161 • 310A • 316 • 317 • 502 • 502A • 503 • 504 • 506 • 515 • 516 • 519 • 526 • 529 • RM529 • 533 • 535 • 536 • 543 • 544 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 556 • 561A • 561S • 564 • 565 • 567 • 581 • 581A • 585 • 585A • 661 • 1A4 • 1S1 • 60 • 2A60 • 63 • 2A63 • 67 • 2B67 • 3A1 • 3A1S • 3A2 • 3A3 • 3A6 • 3A7 • 72 • 3A72 • 75 • 3A75 • 4S2 • 51 • 3B1 • 3B1S • 3B2 • 3B3 • 3B4 • 3M1 • 3S76 • 3T77 • 3T77A • 9A1 • 9A2 • 1121 • 80 • 81 • 82 • 86 • B • O • W • Z • Telequipment D56 • Telequipment S32A • Telequipment D52 • S-311 • Telequipment TD51 • Telequipment S52 • Telequipment S51 • Telequipment Type A • TU-4 |