1S2: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(12 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar  
title=Tektronix 1S2|
|manufacturer=Tektronix
summary=Sampling system/TDR|
|series=500-series scopes
image=1s2_front.jpg |  
|type=1S2
caption=1S2 front view|
|summary=Sampling system/TDR
introduced=1967 |
|image=Tek 1s2 front.jpg  
discontinued=1973 |
|caption=1S2 front view
series=[[500-series scopes]]|
|introduced=1967
manuals=
|discontinued=1973
* [[Media:070-0889-00.pdf|1S2 manual (PDF, sn 1990 and up, OCR)]]
|designers=Chuck Edgar;Gene Cowan
* [http://www.pa4tim.nl/wp-content/uploads/2012/01/1S2calibrationPA4TIM.pdf 1S2 Calibration Guide by Fred Schneider, PA4TIM]
|manuals=
* [http://www.pa4tim.nl/?p=3016 1S2 Page on the Website of Fred Schneider, PA4TIM]
* [[Media:070-0889-00.pdf|1S2 manual]] (S/N 1990+, OCR)
* [[Media:Tek 1s2 fcp june 1966.pdf‎]]
* ''Manual needed for sn below 1990 [[Category:Manual needed]]''
* [[Media:Tek 1s2 fcp aug 1968.pdf‎]]
* [[Media:Tek 1s2 fcp june 1966.pdf‎|Tektronix 1S2 Factory Calibration Procedure, June 1966]]
 
* [[Media:Tek 1s2 fcp aug 1968.pdf‎|Tektronix 1S2 Factory Calibration Procedure, August 1968]]
<!-- * [[Media:1S2_calibration_guide.pdf|1S2 Calibration Guide by Fred Schneider, PA4TIM (PDF, OCR)]] -->
* [[Media:Tek 1s2 cal outline.pdf|Tektronix 1S2 Calibration Outline]]
 
<!-- * [[Media:1S2_calibration_guide.pdf|1S2 Calibration Guide by Fred Schneider, PA4TIM]] -->
}}
}}
The '''Tektronix 1S2''' is a [[sampling oscilloscope|sampling]]/TDR plug-in for [[500-series scopes]], [[introduced in 1967]] and sold through 1972.
The '''Tektronix 1S2''' is a [[sampling oscilloscope|sampling]]/TDR plug-in for [[500-series scopes]], [[introduced in 1967]] and sold through 1972.
[[Chuck Edgar]] designed the sweep circuitry and [[Gene Cowan]] designed the vertical circuitry.


Like the [[1S1]], it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display.
Like the [[1S1]], it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display.
Line 43: Line 44:
==Links==
==Links==


* [[Media:062-1244-00.pdf | Tektronix 062-1244-00: Time-Domain Reflectometry Measurement Concepts]], James A. Strickland, 1969. pages. PDF, OCR, 6.2 MB
* [https://www.pa4tim.nl/wp-content/uploads/2012/01/1S2calibrationPA4TIM.pdf 1S2 Calibration Guide by Fred Schneider, PA4TIM]
* [[Media:Service Scope 45 Aug 1967.pdf  | Service Scope No. 45, August 1967 - Time-Domain Reflectometry Theory]]
* [https://www.pa4tim.nl/?p=3016 1S2 Page on the Website of Fred Schneider, PA4TIM]
* [[Media:Service Scope 38 Jun 1966.pdf | Service Scope No. 38, June 1966 - Tektronix Type 1S2 Makes Reflectometry Easy]]
* [https://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]
* [http://w140.com/kurt/50_years_sampling.pdf 50 Years of RF and Microwave Sampling, Mark Kahrs]
{{Documents|Link=1S2}}
* [http://www.picosecond.com/objects/AN-04.pdf Picosecond Pulse Labs Application Note 4: TDR]
{{PatentLinks|1S2}}
{{Documents|Link=Time domain reflectometers}}


==Pictures==
==Pictures==
Line 67: Line 69:
</gallery>
</gallery>


 
==Components==
{{Parts|1S2}}


[[Category:Sampling plugins]]
[[Category:Sampling plugins]]
Line 73: Line 76:
[[Category:500 series plugins]]
[[Category:500 series plugins]]
[[Category:GR874]]
[[Category:GR874]]
[[Category:Manual needed]]

Latest revision as of 14:00, 4 November 2024

Tektronix 1S2
Sampling system/TDR
1S2 front view

Compatible with 500-series scopes

Produced from 1967 to 1973

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 1S2 is a sampling/TDR plug-in for 500-series scopes, introduced in 1967 and sold through 1972. Chuck Edgar designed the sweep circuitry and Gene Cowan designed the vertical circuitry.

Like the 1S1, it is a complete sampling subsystem and uses the mainframe merely as a power supply and low-speed X-Y display. The 1S2 outputs the Y-axis signal on plug-in interface connector pins 1 and 3 like other 500-series plug-ins, and the X-axis signal on the front panel, via a banana connector. The X-axis sensitivity of the oscilloscope mainframe is expected to be 1 V/div.

Unlike the 1S1, the 1S2 contains pulsers that allows it to perform time-domain reflectometry (TDR) measurements. The 1S2 has two 50 Ω pulsers, one of which is active at a time. One puts out a 250 mV pulse with 50 ps rise time. The other puts out a slower 1 V pulse. The sampling bridge is a feed-through type.

For TDR measurements, the signal from one of the internal pulsers is fed through the sampler, and out to the transmission line being tested. Returning pulses are detected as they pass back through the sampler, and they are reabsorbed by the 50 Ω impedance of the pulser.

Waveform output can be to the CRT of the mainframe and/or to a plotter or low-speed data acquisition device via banana connectors on the front of the 1S2.

The interface between the GR-874 connector and the printed circuit board is described in US Patent 3,426,311.

Key Specifications

  • please add

Internals

The 1S2 contains an internal power supply producing regulated +19 V, -19 V, and -136 V outputs, derived from a power transformer whose primary voltage is the 6.3 VAC provided by the 500-series mainframe on pins 13 and 14 of the plug-in interface connector. The regulators use bipolar transistors for the feedback amplifiers and the output emitter-followers, and zener diodes as references.

Links

Documents Referencing 1S2

Document Class Title Authors Year Links
Service Scope 38 Jun 1966.pdf Article Tektronix Type 1S2 Makes Reflectometry Easy 1966
Service Scope 45 Aug 1967.pdf Article Time-Domain Reflectometry Theory and the Testing of Coaxial Transmission Lines 1967
Service Scope 52 Oct 1968.pdf Article Service Notes - Optimizing System Risetime (1S2) 1968

Documents Referencing Time domain reflectometers

Document Class Title Authors Year Links
Service Scope 38 Jun 1966.pdf Article Tektronix Type 1S2 Makes Reflectometry Easy 1966
Service Scope 45 Aug 1967.pdf Article Time-Domain Reflectometry Theory and the Testing of Coaxial Transmission Lines 1967
062-1244-00.pdf Book Measurement Concepts: Time-Domain Reflectometry Measurements James A. Strickland H. Allen Zimmerman Gordon Long George Frye 1969

Pictures

Components

Some Parts Used in the 1S2

Part Part Number(s) Class Description Used in
1N3717 152-0381-00 152-0125-00 Discrete component 4.7 mA, 25 pF tunnel diode 1L40 1S1 1S2 11B1 11B2 11B2A 147A 1470 148 21A 22A 3B4 3B5 408 432 434 453 453A 454 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
SMTD995 152-0140-01 Discrete component 10 mA, 8 pF tunnel diode 1S1 1S2 1502 21A 22A 3T5 3T6 475 475A 475M 544 R544 546 RM546 547 RM547 556 R556 581A 585A RM585 7B52 7B53N 7B70 7B71 7D10 7D11 7T11 7T11A R7912 S-51 S-52 TU-5 067-0572-00 067-0572-01 067-0681-00
STD932 152-0373-00 Discrete component 4.7 mA, 50 pF tunnel diode 31 1S2 115 564B R564B
STD933 152-0181-00 Discrete component 1 mA, 5 pF germanium tunnel diode 1S2 221 422
STD962 152-0169-00 Discrete component 1 mA, 10 pF tunnel diode L140 Pentrix L20 Pentrix L30 067-0518-00 067-0594-00 1L60 1S2 1503 3B5 3T7 4054 4054A 4902 5S14N 7S14 7T11