2440: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
 
(19 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar|
{{Oscilloscope Sidebar  
title=Tektronix 2440 |
|manufacturer=Tektronix
image=2440_1.jpg |
|series=2400-series scopes
caption=Tektronix 2440  |
|model=2440  
introduced=1988 |  
|image=2440_1.jpg  
discontinued=(?) |
|caption=Tektronix 2440   
summary=300 MHz, 500 MS/s 2-ch digital scope |
|introduced=1988  
manuals=
|discontinued=(?)  
* [http://w140.com/tek_2440_service.pdf Tektronix 2440 Manual (complete, B014064 and below) (PDF, OCR)]
|summary=300 MHz, 500 MS/s 2-ch digital scope  
* [http://w140.com/tek_2440_programmer_man.pdf Tektronix 2440 Programmer Manual (PDF, OCR)]
|designers=
* [http://w140.com/tek_2440.pdf Tektronix 2440 Manual (without schematics) (PDF)]
|manuals=
* [[Media:2430A-2432A-2440-catalog.pdf|2430A/2432A/2440 catalog page (PDF, OCR)]]
* [[Media:070-6599-00.pdf|Tektronix 2440 Operators Manual]]
* [[Media:070-6600-00.pdf|Tektronix 2440 User Reference]]
* [[Media:070-6601-00.pdf|Tektronix 2440 Programmer Manual]]
* [[Media:070-6602-00.pdf|Tektronix 2440 GPIB Pocket Guide]]
* [[Media:070-6603-00.pdf|Tektronix 2440 Service Manual (complete, B014064 and below)]]
 
* [https://w140.com/tek_2440.pdf Tektronix 2440 Service Manual (without schematics)]
* [[Media:2430A-2432A-2440-catalog.pdf|2430A/2432A/2440 catalog page]] (OCR)
{{ROM Images}}
}}
}}
The '''Tektronix 2440''' is a two-channel 300 MHz, 500 MS/s digital sampling oscilloscope from the late 1980s.
The '''Tektronix 2440''' is a two-channel 300 MHz, 500 MS/s digital sampling oscilloscope from the late 1980s.
Line 18: Line 26:
<blockquote>
<blockquote>
'''WARNING:'''<br />
'''WARNING:'''<br />
Operation of the 2440 (and 2432 and 2430): A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
Operation of the 2440, 2439, 2432, 2432A, 2431L, 2430, 2430A and 2424L : A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
</blockquote>
</blockquote>


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | 300 MHz (Limit: 20, 100, Full) }}
{{Spec | Bandwidth | 300 MHz (Limit: 20, 100, Full) }}
{{Spec | Rise time | 1.2 ns (Repeat on, 16×averaging)}}
{{Spec | Sampling rate | 500 MSa/s each channel with simultaneous acquisition }}
{{Spec | Sampling rate | 500 MSa/s each channel with simultaneous acquisition }}
{{Spec | Sampling type | Real time: 100 ns/Div and slower, Equivalent time 50 ns/Div and faster}}
{{Spec | Single event bandwidth  | 200 MHz}}
{{Spec | Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence }}
{{Spec | Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence }}
{{Spec | Auto Scale Factor | On-Screen Readout indicates probe tip deflection factors for ×1, ×10, ×100 and ×1000 probes }}
{{Spec | Resolution | 8 bit }}
{{Spec | Input Impedance| 1 MΩ // 15 pF }}
{{Spec | Record length | 1024 samples }}
{{Spec | Sweep Speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)}}
{{Spec | Auto scale factor | On-Screen Readout indicates probe tip deflection factors for ×1, ×10, ×100 and ×1000 probes }}
{{Spec | Auto Measure| Simultaneously measures up to four parameters on one or more displayed waveforms, updated at 3 Hz intervals or display a snapshot of 20 parameters of waveform target }}
{{Spec | Input impedance| 1 MΩ // 15 pF or 50Ω }}
{{Spec | Acquisition Modes| Normal, Envelope (glitch capture), Average }}
{{Spec | Sweep speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)}}
{{Spec | Display Modes| CH1, CH2, invert, add, multiply, X-Y }}
{{Spec | Auto measure| Simultaneously measures up to four parameters on one or more displayed waveforms, updated at 3 Hz intervals or display a snapshot of 20 parameters of waveform target }}
{{Spec | Acquisition modes| Normal, Envelope (glitch capture), Average }}
{{Spec | Display modes| CH1, CH2, invert, add, multiply, X-Y }}
{{Spec | Cursors  | Volts, Time, Volts At Time, 1/Time, Slope }}
{{Spec | Cursors  | Volts, Time, Volts At Time, 1/Time, Slope }}
{{Spec | Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more }}
{{Spec | Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more }}
Line 48: Line 61:
* 05 - Video Waveform Measurement System
* 05 - Video Waveform Measurement System
* 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel
* 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel
* 22 - Two addtional [[P6137]] probes included
}}
}}
{{EndSpecs}}
{{EndSpecs}}
Line 53: Line 67:
==Links==
==Links==
* [https://hohlerde.org/rauch/en/elektronik/geraete/tek2440/  Tektronix 2440 internals & repair @ hohlerde.org]
* [https://hohlerde.org/rauch/en/elektronik/geraete/tek2440/  Tektronix 2440 internals & repair @ hohlerde.org]
{{Documents|Link=2440}}
{{PatentLinks|2440}}


==Internals==
==Internals==
The 2440 employs several processors − an MC68B09 main CPU controls the instrument, a custom 16-bit waveform processor performs signal computations, and an MC6805 microcontroller handles the front panel interface.  The GPIB Interface is implemented with a TMS9914 controller.
The 2440 employs several processors − an [[Motorola 6809|MC68B09]] main CPU controls the instrument, a custom 16-bit waveform processor performs signal computations, and an [[Motorola 6805|MC6805]] microcontroller handles the front panel interface.  The GPIB Interface is implemented with a [[TMS9914]] controller.


The power supply consists of a buck-type pre-regulator followed by a push-pull inverter and linear post-regulators (except for the +5 V digital supply rail).
The power supply consists of a buck-type pre-regulator followed by a push-pull inverter and linear post-regulators (except for the +5 V digital supply rail).
Line 72: Line 88:
2440 1B.jpg
2440 1B.jpg
</gallery>
</gallery>
==Components==
{{Parts|2440}}


[[Category:2400 series scopes]]
[[Category:2400 series scopes]]

Latest revision as of 07:18, 21 September 2024

Tektronix 2440
300 MHz, 500 MS/s 2-ch digital scope
Tektronix 2440

Produced from 1988 to (?)

Manuals
ROM Images
File Pos. Checksum
160-4941-07 U670 534f735c
160-4942-07 U680 f750a23d
160-4943-07 U682 20b8e47a
160-4944-07 U690 a1a97b15
160-5843-07 U682H ffba3e36
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2440 is a two-channel 300 MHz, 500 MS/s digital sampling oscilloscope from the late 1980s.

It uses CCDs (essentially, analog shift registers) to store input samples at high speed and a single 8 bit flash A/D converter to digitize the time-multiplexed CCD output signals at 4 MS/s.

WARNING:
Operation of the 2440, 2439, 2432, 2432A, 2431L, 2430, 2430A and 2424L : A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.

Key Specifications

Bandwidth 300 MHz (Limit: 20, 100, Full)
Rise time 1.2 ns (Repeat on, 16×averaging)
Sampling rate 500 MSa/s each channel with simultaneous acquisition
Sampling type Real time: 100 ns/Div and slower, Equivalent time 50 ns/Div and faster
Single event bandwidth 200 MHz
Deflection 2 mV/div to 5 V/div in 1-2-5 sequence
Resolution 8 bit
Record length 1024 samples
Auto scale factor On-Screen Readout indicates probe tip deflection factors for ×1, ×10, ×100 and ×1000 probes
Input impedance 1 MΩ // 15 pF or 50Ω
Sweep speeds 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)
Auto measure Simultaneously measures up to four parameters on one or more displayed waveforms, updated at 3 Hz intervals or display a snapshot of 20 parameters of waveform target
Acquisition modes Normal, Envelope (glitch capture), Average
Display modes CH1, CH2, invert, add, multiply, X-Y
Cursors Volts, Time, Volts At Time, 1/Time, Slope
Functions A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more
Interface GPIB
Probes Two passive P6137 400 MHz ×10 voltage probes, 1.3 m
Power 90 to 132 VAC or 80 to 250 VAC, 48 to 440 Hz; 160 W
Features
  • Autoprobe Function With P6137 Probe
  • 300 MHz X-Y bandwidth at probe tip
  • Automatic measurements
  • extensive triggering capabilities
  • Printer/Plotter Output
  • On-screen HELP text describing every front-panel control
Options

Links

Documents Referencing 2440

(no results)

Internals

The 2440 employs several processors − an MC68B09 main CPU controls the instrument, a custom 16-bit waveform processor performs signal computations, and an MC6805 microcontroller handles the front panel interface. The GPIB Interface is implemented with a TMS9914 controller.

The power supply consists of a buck-type pre-regulator followed by a push-pull inverter and linear post-regulators (except for the +5 V digital supply rail).

CRT is a 154-0850-01.

Pictures

Components

Some Parts Used in the 2440

Part Part Number(s) Class Description Used in
148-0140-00 148-0140-00 Discrete component miniature bi-stable relay actuator 2424L 2430 2431L 2432 2439 2440 119-1445-02
154-0850-01 154-0850-00 154-0850-01 CRT CRT 2424L 2430 2430A 2431L 2432 2439 2440 2445 2465 2465A 2465B
155-0242-00 155-0242-00 155-0242-01 Hybrid integrated circuit Z-axis amplifier and autofocus 2215 2252 2440 2445 2445B 2465 2465B 2467 2467B
155-0294-00 155-0294-00 155-0294-01 Monolithic integrated circuit Z-axis amplifier 2424L 2440
165-2273-00 165-2273-00 Hybrid integrated circuit peak detector 2432 2432A 2440
Motorola 6809 156-1494-00 156-1494-01 Monolithic integrated circuit 8-bit microprocessor 2424L 2440 7D20 DM5120 DM5520 Keithley 193A Keithley 196 Keithley 199
TMS9914 156-1444-00 156-1444-01 Monolithic integrated circuit GPIB controller 11301 11301A 11302 11302A 2221 2230 2424L 2440 4052A 4054A 021-0374-00 067-1137-99 AM700 DC5009 DC5010 DM5010 DM5110 DM5120 DM5520 FG5010 MI5010 SG5010 SG5030 SI5010 PS5004 PS5010 Keithley 182 Keithley 193A Keithley 195 Keithley 195A Keithley 196 Keithley 197 Keithley 199 Keithley 220 Keithley 224 Keithley 230 Keithley 263 Keithley 617