3B4: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(9 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | ||
| manufacturer=Tektronix | |||
| series=560-series scopes | |||
series= | | type=3B4 | ||
image=3b4_front.jpg| | | summary=Timebase plug-in | ||
caption=3B4 | | designers= | ||
introduced=1964 | | | image=3b4_front.jpg | ||
discontinued=(?) | | | caption=3B4 Front View | ||
manuals= | | introduced=1964 | ||
* [ | | discontinued=(?) | ||
* [ | | manuals= | ||
* [[Media:Tek 3b4 fcp | * [[Media:070-431.pdf|Tektronix 3B4 Manual]] (OCR) | ||
* [[Media:Tek 3b4 fcp jan 1969.pdf|Tektronix 3B4 Factory Calibration Procedure, January 1969]] | |||
* [[Media:Tek 3b4 fcp june 1967.pdf|Tektronix 3B4 Factory Calibration Procedure, June 1967]] | |||
}} | }} | ||
The '''Tektronix Type 3B4''' is a timebase plug-in for [[560-series scopes]] | The '''Tektronix Type 3B4''' is a timebase plug-in for [[560-series scopes]], introduced in 1964. | ||
It was intended primarily for use with the [[561A]], but works fine in other 560-series scopes. | It was intended primarily for use with the [[561A]], but works fine in other 560-series scopes. | ||
Line 20: | Line 21: | ||
In the triggered modes, the [[tunnel diodes|tunnel diode]]-based triggering is rated to work to 20 MHz. | In the triggered modes, the [[tunnel diodes|tunnel diode]]-based triggering is rated to work to 20 MHz. | ||
The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate. | The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate. | ||
{{MissingSpecs}} | {{MissingSpecs}} | ||
Line 31: | Line 26: | ||
==Links== | ==Links== | ||
* [http://www.barrytech.com/tektronix/vintage/tek3b4.html Tek 3B4 @ barrytech.com] | * [http://www.barrytech.com/tektronix/vintage/tek3b4.html Tek 3B4 @ barrytech.com] | ||
{{Documents|Link=3B4}} | |||
==Internals== | |||
Triggering is done with a [[TD3A]]/1N3717 4.7 mA tunnel diode. | |||
The trigger input is amplified and buffered by a [[6DJ8]]-based differential amplifier driving a common-emitter | |||
[[2N964]] germanium PNP transistor whose collector current switches the tunnel diode. | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
3b4_front.jpg| | 3b4_front.jpg| Front View | ||
3b4_left.jpg| | 3b4_left.jpg | Left Side View | ||
3b4_right.jpg| | 3b4_right.jpg| Right Side View | ||
3b4_top.jpg| | 3b4_top.jpg | Top View | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|3B4}} | |||
[[Category:560 series plugins]] | [[Category:560 series plugins]] |
Latest revision as of 16:59, 7 December 2023
The Tektronix Type 3B4 is a timebase plug-in for 560-series scopes, introduced in 1964.
It was intended primarily for use with the 561A, but works fine in other 560-series scopes. The 3B4 is unusual in having an explicit "FREE RUN" mode.
In the triggered modes, the tunnel diode-based triggering is rated to work to 20 MHz. The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate.
Key Specifications
- please add
Links
Documents Referencing 3B4
- (no results)
Internals
Triggering is done with a TD3A/1N3717 4.7 mA tunnel diode. The trigger input is amplified and buffered by a 6DJ8-based differential amplifier driving a common-emitter 2N964 germanium PNP transistor whose collector current switches the tunnel diode.
Pictures
-
Front View
-
Left Side View
-
Right Side View
-
Top View