453: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
 
(24 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar
title=Tektronix 453 |
|manufacturer=Tektronix
summary=50 MHz portable dual-trace scope |
|series=400-series scopes
image=Tek 453 2.jpg |
|model=453
caption=Tektronix 453 front |
|summary=50 MHz portable dual-trace scope
introduced=1965 |
|image=Tek 453 2.jpg
discontinued=1974 |
|caption=Tektronix 453 front
manuals=
|introduced=1965
*[http://w140.com/mmm/tek-453.pdf Tektronix 453 Manual (PDF)]
|discontinued=1974
*[http://w140.com/mmm/tek-453a.pdf Tektronix 453A Manual (PDF)]
|designers=Oliver Dalton;Gene Andrews;
*[http://w140.com/tek_453_military_manual.pdf Tektronix 453 Manual, Military Version (PDF)]
|manuals=
*[http://w140.com/453A_Operators_handbook_1970_ocrd.pdf Tektronix 453A Operators Handbook (OCR, PDF)]
'''453'''
* [http://w140.com/tek_453_irb.pdf Tektronix 453 Instrument Reference Book (OCR, PDF)]
* [[Media:070-0478-00.pdf                       | Tektronix 453 Instruction Manual]]
* [[Media:Tek type 453 lecture notes.pdf|Tektronix Type 453 Lecture Notes (PDF)]]
* [[Media:070-0755-02.pdf                       | Tektronix 453 Service Manual SN 20,000+]]
* [[Media:070-0478-00.pdf|Tektronix 453 Manual (PDF, OCR)]]
* [[Media:Tek_453_military_manual.pdf           | Tektronix 453 Manual, Military Version]]
* [[Media:070-1089-00.pdf|Tektronix 453A Manual (PDF, OCR)]]
* [[Media:Tek_453_irb.pdf                       | Tektronix 453 Instrument Reference Book]]
* [[Media:Tek 453 fcp sn2k-up october 1967.pdf|Tektronix 453 Factory Calibration Procedure, October 1967 (PDF, needs OCR)]]
'''453A'''
* [[Media:Tek 453 fcp dec 1968.pdf|Tektronix 453 Factory Calibration Procedure, December 1968 (PDF, needs OCR)]]
* [[Media:070-1089-00.pdf                       | Tektronix 453A Manual]]
* [[Media:Tek 453 mod 703k.pdf|Tektronix 453 Mod 703K]]
* [[Media:453A_Operators_handbook_1970_ocrd.pdf | Tektronix 453A Operators Handbook]]
* [[Media:Tek 453 703H 703K.pdf|Tektronix 453 Mod 703H and 703K]]
* [[Media:070-1089-00 M17637-OCR.pdf           | Tektronix 453A Manual Change M17637]]
* [[Media:070-1166-00.pdf                       | Tektronix 453A-4 Manual]]
<small>
'''Modifications, Calibration'''
* [[Media:Tek type 453 lecture notes.pdf        | Tektronix Type 453 Lecture Notes]]
* [[Media:Tek 453 fcp sn2k-up october 1967.pdf | Tektronix 453 Factory Calibration Procedure, October 1967]]
* [[Media:Tek 453 fcp dec 1968.pdf             | Tektronix 453 Factory Calibration Procedure, December 1968]]
* [[Media:Tek 453 cal outline.pdf              | Tektronix 453 Calibration Outline]]
* [[Media:Tek 453 mod 703k.pdf                 | Tektronix 453 Mod 703K]]
* [[Media:Tek 453 703H 703K.pdf                 | Tektronix 453 Mod 703H and 703K]]
</small>
}}
}}
The '''Tektronix 453''' is a portable 50 MHz dual-trace oscilloscope [[introduced in 1965]] and produced until the mid-1970's.
The '''Tektronix 453''' is a portable 50 MHz dual-trace oscilloscope [[introduced in 1965]] and produced until the mid-1970's.  
It was designed by [[Oliver Dalton]] and [[Gene Andrews]].


The main market driver for the 453 scope was IBM, who wanted a portable scope for Computer Field Engineers  
The main market driver for the 453 scope was IBM, who wanted a portable scope for Computer Field Engineers  
Line 29: Line 40:


The 453 also marks the first time that any oscilloscope, (or perhaps any other piece of test equipment),
The 453 also marks the first time that any oscilloscope, (or perhaps any other piece of test equipment),
had a lockable dual duty tilt bail carrying handle.  
had a lockable dual-duty tilt-bail carrying handle.  
Tek held a patent on that feature, as well as on some of the other ergonomics that made up the 400 series.
Tek held a patent on that feature, as well as on some of the other ergonomics that made up the 400 series.


Line 36: Line 47:
{{Spec | Rise time      | 6.7 ns (20 mV/Div and up), 7.5 ns @ 10 mV/Div, 8.75 ns @ 5 mV/Div, 14 ns @ 1 mV/Div (A-B cascaded) }}
{{Spec | Rise time      | 6.7 ns (20 mV/Div and up), 7.5 ns @ 10 mV/Div, 8.75 ns @ 5 mV/Div, 14 ns @ 1 mV/Div (A-B cascaded) }}
{{Spec | Deflection      | 5 mV/Div to 10 V/Div, 11 steps (1-2-5), variable  ×2.5 (i.e. up to 25 V/Div); 1 mV/Div with cascaded channels A+B in 5 mV/Div setting }}
{{Spec | Deflection      | 5 mV/Div to 10 V/Div, 11 steps (1-2-5), variable  ×2.5 (i.e. up to 25 V/Div); 1 mV/Div with cascaded channels A+B in 5 mV/Div setting }}
{{Spec | Time base      | 0.1 ms/Div to 5 s/Div, 24 steps (1-2-5) }}
{{Spec | Time base      | 0.1 μs/Div to 5 s/Div, 24 steps (1-2-5) }}
{{Spec | Input impedance | 1 MΩ // 20 pF }}
{{Spec | Input impedance | 1 MΩ // 20 pF }}
{{Spec | Probes          | Two [[P6010]] 3.5ft 10X Probes }}
{{Spec | Probes          | Two [[P6010]] 3.5ft 10X Probes }}
{{Spec | Power          | 96-137 V / 192-274 V in 4 ranges, 45-440 Hz, 100 W }}
{{Spec | Power          | 96-137 V / 192-274 V in 4 ranges, 45-440 Hz, 100 W }}
{{Spec | Wight          | 13.2 kg (29.1 lb) }}
{{Spec | Weight          | 13.2 kg (29.1 lb) }}
{{Spec | Environmental  | Meets Mil-Std-202B. Will not fail if exposed to 30 g shock test, heavy humidity, ect. }}
{{Spec | Environmental  | Meets Mil-Std-202B. Will not fail if exposed to 30 g shock test, heavy humidity, ect. }}
{{EndSpecs}}
{{EndSpecs}}
==Links==
* [https://youtube.com/watch?v=SESxlqvbzig Gale Morris on the history of the Tektronix 453 Oscilloscope] (YouTube)
* [https://www.antiqueradios.com/forums/viewtopic.php?f=8&t=295306&hilit=453+rewind&start=20 Antique Radio Forum thread discussing Tek 453 HV transformer]
* [https://web.archive.org/web/20131026150847/http://www.diyguitarist.com/TestEquipment/Tektronix453.htm Paul Marossy's Tek 453 page (archived copy, original site down as of Feb 2015)]
* [https://w140.com/gao_B-176564.txt US Government Accounting Office Purchasing Decision and Discussion of  453 Mod 703H (PDF)]
* [https://readingjimwilliams.blogspot.co.at/2011/07/scope-sunday-3.html Reading Jim Williams blog: Scope Sunday #3 - Tek 453 story]
* [https://web.archive.org/web/2017*/http://www.reprise.com/host/scopes/ Bill's Tektronix 453 and 454 Info Pages] (defunct, link via Internet Archive)
<!-- Dead link: [http://vondervotteimittiss.com/belfry/?p=248 A 453 HV supply repair] (nice pictures) -->
{{Documents|Link=453}}
{{Documents|Link=453A}}
==Prices==
{| class="wikitable"
|-
! Year
! 1966
! 1968
! 1970
! 1972 (A)
! 1973 (A)
|-
! Catalog Price
| $2,050
| $1,950
| $2,050
| $2,050
| $2,050
|-
! In 2023 Dollars
| $19,500
| $17,200
| $16,300
| $15,100
| $14,200
|}


==Internals==
==Internals==
The 453 is almost entirely solid-state, even in its first version, except for the [[5642]] HV rectifiers and CRT.   
The 453 is almost entirely solid-state, even in its first version, except for the [[5642]] HV rectifiers and CRT.   
Early 453's (below serial number 20,000) used a few [[8393]] Nuvistor triode tubes.  The 453A, [[introduced in 1971]],  
Early 453's (below serial number 20,000) used six [[8393]] Nuvistor triode tubes (two of them paired).   
was fully transistorized, with extended bandwidth to 60 MHz, increased the graticule from 6 cm × 10 cm to 8 cm × 10 cm,
The 453A, [[introduced in 1971]], was fully transistorized, with extended bandwidth to 60 MHz, increased the graticule from 6 × 10 cm² to 8 × 10 cm², and introduced a mixed-sweep mode.   
and introduced a mixed-sweep mode.  Mixed-sweep mode starts the sweep at the "A" time/div rate and  
Mixed-sweep mode starts the sweep at the "A" time/div rate and then, after a delay set by a ten-turn vernier dial, continues at the "B" sweep time/div rate.
then, after a delay set by a ten-turn vernier dial, continues at the "B" sweep time/div rate.


There are two trigger/sweep units in a 453, thereby enabling delayed sweep mode.   
There are two trigger/sweep units in a 453, thereby enabling delayed sweep mode.   
There are two delayed sweep modes: "B runs after A" and "B triggerable after A".  
There are two delayed sweep modes: "B runs after A" and "B triggerable after A".  
The A and the B sweep triggering both use [[tunnel diodes]],  
The A and the B sweep triggering both use [[tunnel diodes]], with a trigger preamplifier preceding the actual trigger circuit.  
with a trigger preamplifier preceding the actual trigger circuit.  
The use of tunnel (Esaki) diodes gave the 453 triggering that is stable and useful to twice the oscilloscope's bandwidth.   
The use of tunnel (Esaki) diodes gave the 453 triggering that is stable and
useful to twice the oscilloscope's bandwidth.   


The vertical amplifier that drives the CRT ([[T4533]]) deflection plates  
The vertical amplifier that drives the CRT ([[T4533]]) deflection plates is a cascoded differential amplifier made of NPN transistors.
is a cascoded differential amplifier made of NPN transistors.
Each horizontal deflection plate is driven by a common-emitter amplifier with feedback.   
Each horizontal deflection plate is driven by a common-emitter amplifier with feedback.   


The total CRT acceleration is 10 kV.
The 453 uses the [[Media:Tek 120-0360-00.pdf|120-0360-00]] HV transformer.
The 453 uses the [[Media:Tek 120-0360-00.pdf|120-0360-00]] HV transformer.
The CRT cathode voltage is -2 kV and the CRT anode voltage is +8 kV.  
Total CRT acceleration is 10 kV (cathode −2 kV, anode +8 kV).
 
A Tektronix 453 consumes 100 W power and weighs 29 pounds (13.2 kg).
A Tektronix 453 consumes 100 W power and weighs 29 pounds (13.2 kg).
Part of the heft of this scope is due to its very sturdy aluminum frame and covers.  
Part of the heft of this scope is due to its very sturdy aluminum frame and covers.  
The 453 came with a rigid metal front panel cover with locking latches that protected the scope while it is in transit.   
The 453 came with a rigid metal front panel cover with locking latches that protected the scope while it is in transit.   
This cover has a compartment for storing probes and accessories.   
This cover has a compartment for storing probes and accessories.   
Inside the 453, the electronics are rather densely packed in order for the scope to be compact.   
Inside the 453, the electronics are rather densely packed in order for the scope to be compact.   
The top and bottom cover of the case separate easily using an ingenious thumb screw locking system - truly  
The top and bottom cover of the case separate easily using an ingenious thumb screw locking system - truly  
Line 76: Line 120:
The 453A Mod 127C appears in the 1971 Television Products Catalog, with the description:
The 453A Mod 127C appears in the 1971 Television Products Catalog, with the description:
<blockquote>
<blockquote>
With the Mod 127C, and Internal TV Sync Separator circuit permits
With the Mod 127C, and Internal TV Sync Separator circuit permits stable internal line or Field-rate triggering from displayed composite
stable internal line or Field-rate triggering from displayed composite
video or composite sync waveforms.  External /10 trigger sources are replaced by Internal TV Sync positions providing Line sync pulses to the
video or composite sync waveforms.  External /10 trigger sources are  
replaced by Internal TV Sync positions providing Line sync pulses to the
B Sweep circuit and either Field or Line sync pulses to the A sweep circuit.
B Sweep circuit and either Field or Line sync pulses to the A sweep circuit.
</blockquote>
</blockquote>


==Links==
The 453 has a 182 °F / 83 °C thermal cut-out switch.
* [https://youtube.com/watch?v=SESxlqvbzig Gale Morris on the history of the Tektronix 453 Oscilloscope] (YouTube)
* [http://www.antiqueradios.com/forums/viewtopic.php?f=8&t=295306&hilit=453+rewind&start=20 Antique Radio Forum thread discussing Tek 453 HV transformer]
* [https://web.archive.org/web/20131026150847/http://www.diyguitarist.com/TestEquipment/Tektronix453.htm Paul Marossy's Tek 453 page (archived copy, original site down as of Feb 2015)]
* [http://www.reprise.com/host/scopes/ Bill's Tektronix 453 and 454 Info Pages]
* [http://w140.com/gao_B-176564.txt US Government Accounting Office Purchasing Decision and Discussion of  453 Mod 703H (PDF)]
* [http://readingjimwilliams.blogspot.co.at/2011/07/scope-sunday-3.html Reading Jim Williams blog: Scope Sunday #3 - Tek 453 story]
* [http://vondervotteimittiss.com/belfry/?p=248 A 453 HV supply repair] (nice pictures)


==Pictures==
==Pictures==
Line 101: Line 136:
Tek 453 6.jpg
Tek 453 6.jpg
Tek 453 7.jpg
Tek 453 7.jpg
453A-4.JPG|453A-4, simpler version of 453A
Wellenkino 453.jpg           | 453
Tek 453a 4.jpg|453A-4
Tek 453 fine trace.jpg       | The Tektronix 453 has a thin bright trace.
Wellenkino 453.jpg|453
Tek 453 fine trace.jpg|The Tektronix 453 has a thin bright trace.
Tek 453a 3.jpg|453A-3
Tek 453a 1.jpg|453A-1
Tek 453 two sine.jpg
Tek 453 two sine.jpg
Tek 453 on model 3 cart 1.jpg|453 on [[LabCart3|Model 3 Cart]]
Tek 453 on model 3 cart 1.jpg | 453 on [[LabCart3|Model 3 Cart]]
Tek 453 on model 3 cart 2.jpg|453 on Model 3 Cart
Tek 453 on model 3 cart 2.jpg | 453 on Model 3 Cart
Tek 453 on model 3 cart 3.jpg|453 on Model 3 Cart
Tek 453 on model 3 cart 3.jpg | 453 on Model 3 Cart
Tek 453 on model 3 cart 4.jpg|453 on Model 3 Cart
Tek 453 on model 3 cart 4.jpg | 453 on Model 3 Cart
Tek 453 on model 3 cart 5.jpg|453 on Model 3 Cart
Tek 453 on model 3 cart 5.jpg | 453 on Model 3 Cart
Tek 453 with camera mount.jpg|453 with camera mount
Tek 453 with camera mount.jpg | 453 with camera mount
Tek 453a-2 burroughs.jpg|453A-2
453_MG_9796e.jpg             | 453 with IBM logo
453_MG_9796e.jpg
453_MG_9800e.jpg
453_MG_9800e.jpg
453_MG_9798e.jpg  
453_MG_9798e.jpg  
453_MG_9799e.jpg
453_MG_9799e.jpg
</gallery>
</gallery>
===453A===
<gallery>
453A-4.JPG                    | 453A-4, simpler version of 453A
Tek 453a 4.jpg                | 453A-4
Tek 453a 3.jpg                | 453A-3
Tek 453a 1.jpg                | 453A-1
Tek 453a-2 burroughs.jpg      | 453A-2
</gallery>
==Components==
{{Parts|453}}
{{Parts|453A}}


[[Category:400 series scopes]]
[[Category:400 series scopes]]

Latest revision as of 08:48, 19 August 2024

Manuals – Specifications – Links – Pictures

The Tektronix 453 is a portable 50 MHz dual-trace oscilloscope introduced in 1965 and produced until the mid-1970's. It was designed by Oliver Dalton and Gene Andrews.

The main market driver for the 453 scope was IBM, who wanted a portable scope for Computer Field Engineers to use for working on mainframe computers. In addition, they had a requirement that the scope had to fit under an airline seat, another reason for its size and the front cover. One can even find 453's (and 465's/475's) with "IBM" screened on the front panel by Tek.

The 453 also marks the first time that any oscilloscope, (or perhaps any other piece of test equipment), had a lockable dual-duty tilt-bail carrying handle. Tek held a patent on that feature, as well as on some of the other ergonomics that made up the 400 series.

Key Specifications

Bandwidth 52.5 MHz (20 mV/Div and up), 46.5 MHz @ 10 mV/Div, 41 MHz @ 5 mV/Div, 25 MHz @ 1 mV/Div (A-B cascaded); AC coupling LF limit 1.6 Hz
Rise time 6.7 ns (20 mV/Div and up), 7.5 ns @ 10 mV/Div, 8.75 ns @ 5 mV/Div, 14 ns @ 1 mV/Div (A-B cascaded)
Deflection 5 mV/Div to 10 V/Div, 11 steps (1-2-5), variable  ×2.5 (i.e. up to 25 V/Div); 1 mV/Div with cascaded channels A+B in 5 mV/Div setting
Time base 0.1 μs/Div to 5 s/Div, 24 steps (1-2-5)
Input impedance 1 MΩ // 20 pF
Probes Two P6010 3.5ft 10X Probes
Power 96-137 V / 192-274 V in 4 ranges, 45-440 Hz, 100 W
Weight 13.2 kg (29.1 lb)
Environmental Meets Mil-Std-202B. Will not fail if exposed to 30 g shock test, heavy humidity, ect.

Links

Documents Referencing 453

Document Class Title Authors Year Links
Service Scope 50 Jun 1968.pdf Article The FET takes its place 1968
Tekscope 1970 V2 N4 Aug 1970.pdf Article Troubleshooting the 453 Charles Phillips 1970

Documents Referencing 453A

Document Class Title Authors Year Links
Tekscope 1971 V3 N2.pdf Article New Portables 1971
Tekscope 1971 V3 N3 May 1971.pdf Article The New Portables 1971
Tekscope 1971 V3 N5 Sep 1971.pdf Article A Practical Approach to Regulated Power Supplies as Operational Amplifiers Fred Beckett 1971

Prices

Year 1966 1968 1970 1972 (A) 1973 (A)
Catalog Price $2,050 $1,950 $2,050 $2,050 $2,050
In 2023 Dollars $19,500 $17,200 $16,300 $15,100 $14,200

Internals

The 453 is almost entirely solid-state, even in its first version, except for the 5642 HV rectifiers and CRT. Early 453's (below serial number 20,000) used six 8393 Nuvistor triode tubes (two of them paired). The 453A, introduced in 1971, was fully transistorized, with extended bandwidth to 60 MHz, increased the graticule from 6 × 10 cm² to 8 × 10 cm², and introduced a mixed-sweep mode. Mixed-sweep mode starts the sweep at the "A" time/div rate and then, after a delay set by a ten-turn vernier dial, continues at the "B" sweep time/div rate.

There are two trigger/sweep units in a 453, thereby enabling delayed sweep mode. There are two delayed sweep modes: "B runs after A" and "B triggerable after A". The A and the B sweep triggering both use tunnel diodes, with a trigger preamplifier preceding the actual trigger circuit. The use of tunnel (Esaki) diodes gave the 453 triggering that is stable and useful to twice the oscilloscope's bandwidth.

The vertical amplifier that drives the CRT (T4533) deflection plates is a cascoded differential amplifier made of NPN transistors. Each horizontal deflection plate is driven by a common-emitter amplifier with feedback.

The 453 uses the 120-0360-00 HV transformer. Total CRT acceleration is 10 kV (cathode −2 kV, anode +8 kV).

A Tektronix 453 consumes 100 W power and weighs 29 pounds (13.2 kg). Part of the heft of this scope is due to its very sturdy aluminum frame and covers. The 453 came with a rigid metal front panel cover with locking latches that protected the scope while it is in transit. This cover has a compartment for storing probes and accessories.

Inside the 453, the electronics are rather densely packed in order for the scope to be compact. The top and bottom cover of the case separate easily using an ingenious thumb screw locking system - truly the only scope series that could be opened for service/calibration in a few seconds. Removing the rear cover exposes the remaining fuses and circuitry that rarely required access.

The 453A Mod 127C appears in the 1971 Television Products Catalog, with the description:

With the Mod 127C, and Internal TV Sync Separator circuit permits stable internal line or Field-rate triggering from displayed composite video or composite sync waveforms. External /10 trigger sources are replaced by Internal TV Sync positions providing Line sync pulses to the B Sweep circuit and either Field or Line sync pulses to the A sweep circuit.

The 453 has a 182 °F / 83 °C thermal cut-out switch.

Pictures

453A

Components

Some Parts Used in the 453

Part Part Number(s) Class Description Used in
1N3717 152-0381-00 152-0125-00 Discrete component 4.7 mA, 25 pF tunnel diode 1L40 1S1 1S2 11B1 11B2 11B2A 147A 1470 148 21A 22A 3B4 3B5 408 432 434 453 453A 454 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
5642 154-0051-00 154-0079-00 Vacuum Tube (Diode) directly-heated high-voltage rectifier 310 310A 316 317 360 453 502 502A 503 504 506 513 515 516 524 529 RM529 533 533A 535 536 543 543A 543B 545 545A 545B 547 551 555 556 560 561 561A 561S 564 567 570 575 581 581A 585 585A 647 647A
8393 154-0461-00 Vacuum Tube (Triode) Nuvistor triode 453 454 1A6 1A7 503
STD704 152-0125-00 Discrete component 4.7 mA tunnel diode 1L40 1S1 11B1 11B2 11B2A 147 R147 147A R147A 1470 148 R148 148-M 149 R149 149A R149A 21A 22A 3B4 3B5 408 432 434 453 453A 454 464 465 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
T4530 154-0492-04 154-0566-00 CRT CRT 453


Some Parts Used in the 453A

Part Part Number(s) Class Description Used in
1N3717 152-0381-00 152-0125-00 Discrete component 4.7 mA, 25 pF tunnel diode 1L40 1S1 1S2 11B1 11B2 11B2A 147A 1470 148 21A 22A 3B4 3B5 408 432 434 453 453A 454 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
STD704 152-0125-00 Discrete component 4.7 mA tunnel diode 1L40 1S1 11B1 11B2 11B2A 147 R147 147A R147A 1470 148 R148 148-M 149 R149 149A R149A 21A 22A 3B4 3B5 408 432 434 453 453A 454 464 465 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
T4533 154-0630-00 154-0630-05 154-0630-07 154-0630-08 154-0630-09 154-0630-10 CRT CRT 453A