Manuals – Specifications – Links – Pictures

The Tektronix 453 is a portable 50 MHz dual-trace oscilloscope introduced in 1965 and produced until the mid-1970's.

The main market driver for the 453 scope was IBM, who wanted a portable scope for Computer Field Engineers to use for working on mainframe computers. In addition, they had a requirement that the scope had to fit under an airline seat, another reason for its size and the front cover. One can even find 453's (and 465's/475's) with "IBM" screened on the front panel by Tek.

The 453 also marks the first time that any oscilloscope, (or perhaps any other piece of test equipment), had a lockable dual duty tilt bail carrying handle. Tek held a patent on that feature, as well as on some of the other ergonomics that made up the 400 series.

Key Specifications

Bandwidth 52.5 MHz (20 mV/Div and up), 46.5 MHz @ 10 mV/Div, 41 MHz @ 5 mV/Div, 25 MHz @ 1 mV/Div (A-B cascaded); AC coupling LF limit 1.6 Hz
Rise time 6.7 ns (20 mV/Div and up), 7.5 ns @ 10 mV/Div, 8.75 ns @ 5 mV/Div, 14 ns @ 1 mV/Div (A-B cascaded)
Deflection 5 mV/Div to 10 V/Div, 11 steps (1-2-5), variable  ×2.5 (i.e. up to 25 V/Div); 1 mV/Div with cascaded channels A+B in 5 mV/Div setting
Time base 0.1 μs/Div to 5 s/Div, 24 steps (1-2-5)
Input impedance 1 MΩ // 20 pF
Probes Two P6010 3.5ft 10X Probes
Power 96-137 V / 192-274 V in 4 ranges, 45-440 Hz, 100 W
Weight 13.2 kg (29.1 lb)
Environmental Meets Mil-Std-202B. Will not fail if exposed to 30 g shock test, heavy humidity, ect.

Internals

The 453 is almost entirely solid-state, even in its first version, except for the 5642 HV rectifiers and CRT. Early 453's (below serial number 20,000) used six 8393 Nuvistor triode tubes (two of them paired). The 453A, introduced in 1971, was fully transistorized, with extended bandwidth to 60 MHz, increased the graticule from 6 × 10 cm² to 8 × 10 cm², and introduced a mixed-sweep mode. Mixed-sweep mode starts the sweep at the "A" time/div rate and then, after a delay set by a ten-turn vernier dial, continues at the "B" sweep time/div rate.

There are two trigger/sweep units in a 453, thereby enabling delayed sweep mode. There are two delayed sweep modes: "B runs after A" and "B triggerable after A". The A and the B sweep triggering both use tunnel diodes, with a trigger preamplifier preceding the actual trigger circuit. The use of tunnel (Esaki) diodes gave the 453 triggering that is stable and useful to twice the oscilloscope's bandwidth.

The vertical amplifier that drives the CRT (T4533) deflection plates is a cascoded differential amplifier made of NPN transistors. Each horizontal deflection plate is driven by a common-emitter amplifier with feedback.

The 453 uses the 120-0360-00 HV transformer. Total CRT acceleration is 10 kV (cathode −2 kV, anode +8 kV).

A Tektronix 453 consumes 100 W power and weighs 29 pounds (13.2 kg). Part of the heft of this scope is due to its very sturdy aluminum frame and covers. The 453 came with a rigid metal front panel cover with locking latches that protected the scope while it is in transit. This cover has a compartment for storing probes and accessories.

Inside the 453, the electronics are rather densely packed in order for the scope to be compact. The top and bottom cover of the case separate easily using an ingenious thumb screw locking system - truly the only scope series that could be opened for service/calibration in a few seconds. Removing the rear cover exposes the remaining fuses and circuitry that rarely required access.

The 453A Mod 127C appears in the 1971 Television Products Catalog, with the description:

With the Mod 127C, and Internal TV Sync Separator circuit permits stable internal line or Field-rate triggering from displayed composite video or composite sync waveforms. External /10 trigger sources are replaced by Internal TV Sync positions providing Line sync pulses to the B Sweep circuit and either Field or Line sync pulses to the A sweep circuit.

The 453 has a 182 °F / 83 °C thermal cut-out switch.

Links

Pictures


Some Parts Used in the 453

Part Part Number(s) Class Description Used in
1N3717 152-0381-00 152-0125-00 Discrete component 4.7 mA, 25 pF tunnel diode 1L40 1S1 1S2 11B1 11B2 11B2A 147A 1470 148 21A 22A 3B4 3B5 408 432 434 453 453A 454 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
5642 154-0051-00 154-0079-00 Vacuum Tube (Diode) directly-heated high-voltage rectifier 310 310A 316 317 360 453 502 502A 503 504 506 513 515 516 524 529 RM529 533 533A 535 536 543 543A 543B 545 545A 545B 547 551 555 556 560 561 561A 561S 564 567 570 575 581 581A 585 585A 647 647A
8393 154-0461-00 Vacuum Tube (Triode) Nuvistor triode 453 454 1A6 1A7 503
STD704 152-0125-00 Discrete component 4.7 mA tunnel diode 1L40 1S1 11B1 11B2 11B2A 147 R147 147A R147A 1470 148 R148 148-M 149 R149 149A R149A 21A 22A 3B4 3B5 408 432 434 453 453A 454 464 465 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
T4530 154-0492-04 154-0566-00 CRT CRT 453


Some Parts Used in the 453A

Part Part Number(s) Class Description Used in
1N3717 152-0381-00 152-0125-00 Discrete component 4.7 mA, 25 pF tunnel diode 1L40 1S1 1S2 11B1 11B2 11B2A 147A 1470 148 21A 22A 3B4 3B5 408 432 434 453 453A 454 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
STD704 152-0125-00 Discrete component 4.7 mA tunnel diode 1L40 1S1 11B1 11B2 11B2A 147 R147 147A R147A 1470 148 R148 148-M 149 R149 149A R149A 21A 22A 3B4 3B5 408 432 434 453 453A 454 464 465 466 491 5T3 544 RM544 546 RM546 547 RM547 556 RM556 7B70 7B71 7D11
T4533 154-0630-00 154-0630-05 154-0630-07 154-0630-08 154-0630-09 154-0630-10 CRT CRT 453A