{{TM5000 | mfg=Tektronix | type=DC5009 | function=135 MHz programmable frequency counter | class=counter | image=Tek dc5009.JPG | introduced=1982 | discontinued=1993 | | {{TM5000 | mfg=Tektronix | type=DC5009 | function=135 MHz programmable frequency counter | class=counter | image=Tek dc5009.JPG | introduced=1982 | discontinued=1993 | | ||
manuals= | designers= |manuals= | ||
* [ | * [[Media:070-3888-00.pdf | Tektronix DC5009 Instruction Manual]] <small>with schematics and changes through 1984</small> | ||
* [[Media:070-3985-00.pdf|Tektronix GPIB Programming Guide]] ([[4052|4050 series]], [[TM5000]] series) | |||
{{ROM Images}} | |||
* U1312 [[Media:160-1076-02.bin|160-1076-02]] | |||
* U1102 [[Media:160-1091-02.bin|160-1091-02]] | |||
* U1201 [[Media:160-1092-02.bin|160-1092-02]] | |||
}} | }} | ||
It is internally similar to the [[DC509]] which could be converted to a 5009 through an upgrade kit. | |||
== | The DC5009 uses reciprocal counting with an internal 100 MHz clock phase-locked to the reference oscillator. | ||
An R6504 microprocessor (28-pin variant of a [[MOS Technology 6502|6502]] with 8K addressable memory) performs the calculations. | |||
Opt.01 is an OCXO for improved stability. | |||
{{BeginSpecs}} | |||
{{Spec | Frequency | ≤100 μHz to ≥135 MHz (Ch B in Ratio: ≥125 MHz) }} | |||
{{Spec | Time A-B | ≤15 ns to ≥3.05 hours }} | |||
{{Spec | Single shot resolution | 10 ns }} | |||
{{Spec | Totalize | 2<sup>40</sup counts (1.09 × 10<sup>12</sup>) }} | |||
{{SpecGroup | Standard time base }} | |||
{{Spec | Frequency | 10 MHz ± 1 × 10<sup>-7</sup> at cal }} | |||
{{Spec | Error | ≤ ±5 × 10<sup>-6</sup> from 0 °C to +50 °C }} | |||
{{Spec | Aging | ≤ ±1 × 10<sup>-6</sup> per year }} | |||
{{SpecGroup | Opt.01 OCXO time base }} | |||
{{Spec | Frequency | 10 MHz ± 2 × 10<sup>-8</sup> at cal }} | |||
{{Spec | Error | ≤ ±2 × 10<sup>-7</sup> from 0 °C to +50 °C (after oven warm-up) }} | |||
{{Spec | Aging | ≤ ±1 × 10<sup>-8</sup> per day }} | |||
{{EndSpecs}} | |||
==Links== | |||
{{Documents|Link=DC5009}} | |||
==Rear interface== | |||
<small> | |||
* 14A − Ext Clock in (1, 5 or 10 MHz, ≥3 V into 1 kΩ) | |||
* 14B − Prescale; when low, counter divides readout by 16 | |||
* 15B − 10 MHz clock out (GND return on 15A) | |||
* 16A − CH A input (50 Ω, ≤10 V<sub>RMS</sub>) (GND return on 17A) | |||
* 17B − CH B input (50 Ω, ≤10 V<sub>RMS</sub>) (GND return on 16B) | |||
* 22A − Trig Level CH A | |||
* 22B − Trig Level CH B | |||
* 23A − Shaped Out A (GND return on 23B) | |||
* 24B − Shaped Out B (GND return on 24A) | |||
* 26A − Reset in (active low) | |||
* 26B − Remote Start | |||
* 27A − Arming in (TTL, active high) (GND return in 28A) | |||
* 28B − Gate Out (TTL, active high) | |||
</small> | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek dc5009.JPG | |||
Tek dc5009 front.jpg | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|DC5009}} |
Latest revision as of 02:44, 8 June 2024
The Tektronix DC5009 is a 135 MHz programmable frequency counter plug-in for the TM5000 system. It is internally similar to the DC509 which could be converted to a 5009 through an upgrade kit.
The DC5009 uses reciprocal counting with an internal 100 MHz clock phase-locked to the reference oscillator. An R6504 microprocessor (28-pin variant of a 6502 with 8K addressable memory) performs the calculations.
Opt.01 is an OCXO for improved stability.
Key Specifications
Frequency | ≤100 μHz to ≥135 MHz (Ch B in Ratio: ≥125 MHz) |
---|---|
Time A-B | ≤15 ns to ≥3.05 hours |
Single shot resolution | 10 ns |
Totalize | 240</sup counts (1.09 × 1012) |
— Standard time base — | |
Frequency | 10 MHz ± 1 × 10-7 at cal |
Error | ≤ ±5 × 10-6 from 0 °C to +50 °C |
Aging | ≤ ±1 × 10-6 per year |
— Opt.01 OCXO time base — | |
Frequency | 10 MHz ± 2 × 10-8 at cal |
Error | ≤ ±2 × 10-7 from 0 °C to +50 °C (after oven warm-up) |
Aging | ≤ ±1 × 10-8 per day |
Links
Documents Referencing DC5009
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekniques vol.6 no.1.pdf | Article | 4050 Controls New Generation of Programmable Instruments for Measurement Automation | 1982 | 4051 • 4052 • TM5000 system • TM5003 • TM5006 • DM5010 • DC5009 • DC5010 • FG5010 • PS5010 • SI5010 • MI5010 • MX5010 | |
070-2088-04.pdf | Book | TM500 Series Rear Interface Data Book | 1985 | AA501 • AF501 • AM501 • AM502 • AM503 • AM511 • DC501 • DC502 • DC503 • DC503A • DC504 • DC505 • DC505A • DC508 • DC508A • DC509 • DC510 • DC5009 • DC5010 • DD501 • DL502 • DM501 • DM501A • DM502 • DM502A • DM505 • DM5010 • FG501 • FG501A • FG502 • FG503 • FG504 • FG507 • FG5010 • LA501 • LA501W • WR501 • MR501 • PG501 • PG502 • PG505 • PG506 • PG507 • PG508 • PS501 • PS502 • PS503 • PS503A • PS505 • PS5010 • RG501 • SC501 • SC502 • SC503 • SC504 • SG502 • SG503 • SG504 • SG505 • SW503 • TG501 • TR501 • TR502 • MI5010 • MX5010 • SI5010 |
Rear interface
- 14A − Ext Clock in (1, 5 or 10 MHz, ≥3 V into 1 kΩ)
- 14B − Prescale; when low, counter divides readout by 16
- 15B − 10 MHz clock out (GND return on 15A)
- 16A − CH A input (50 Ω, ≤10 VRMS) (GND return on 17A)
- 17B − CH B input (50 Ω, ≤10 VRMS) (GND return on 16B)
- 22A − Trig Level CH A
- 22B − Trig Level CH B
- 23A − Shaped Out A (GND return on 23B)
- 24B − Shaped Out B (GND return on 24A)
- 26A − Reset in (active low)
- 26B − Remote Start
- 27A − Arming in (TTL, active high) (GND return in 28A)
- 28B − Gate Out (TTL, active high)
Pictures
Components
Some Parts Used in the DC5009
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
148-0128-00 | 148-0128-00 | Discrete component | miniature magnetic latching relay armature | DC509 • DC5009 • SG5030 |
Rockwell R6504 | 156-1482-00 | Monolithic integrated circuit | 8-bit microprocessor | DC509 • DC5009 |
TMS9914 | 156-1444-00 • 156-1444-01 | Monolithic integrated circuit | GPIB controller | 11301 • 11301A • 11302 • 11302A • 2221 • 2230 • 2424L • 2440 • 4052A • 4054A • 021-0374-00 • 067-1137-99 • AM700 • DC5009 • DC5010 • DM5010 • DM5110 • DM5120 • DM5520 • FG5010 • MI5010 • SG5010 • SG5030 • SI5010 • PS5004 • PS5010 • Keithley 182 • Keithley 193A • Keithley 195 • Keithley 195A • Keithley 196 • Keithley 197 • Keithley 199 • Keithley 220 • Keithley 224 • Keithley 230 • Keithley 263 • Keithley 617 |