7A42: Difference between revisions

1,018 bytes added ,  6 January
no edit summary
No edit summary
No edit summary
Line 21: Line 21:
</small>
</small>
}}
}}
The '''Tektronix 7A42''' is a four-channel 350 MHz plug-in for [[7000-series scopes]].  
The '''Tektronix 7A42''' is a four-channel 350 MHz plug-in for [[7000-series scopes]].  It is a double-wide plug-in, with signal outputs and mainframe readout only using the left slot.


It was specifically designed for logic signals (TTL, ECL, CMOS) and supports triggering based on Boolean conditions of the four inputs.
It was specifically designed for logic signals (TTL, ECL, CMOS) and supports triggering based on Boolean conditions of the four inputs
A fifth trace, "Trigger View", displays the trigger function output or external clock input.  


A fifth trace, "Trigger View", displays the trigger function output or external clock input.
There are two sets of conditions, A and B, that can be individually selected or paired in an "A then B" mode called ''nested triggering'', where the occurrence of condition A arms the trigger and condition B causes the trigger to be generated.
The trigger can be qualified by an external clock.  A trigger filter control, variable from 0-300 ns, allows events shorter than the selected length to be suppressed.  A TTL-level "reset" input will inhibit the trigger if active.


The input V/Div setting can only be seen in the mainframe's readout.
Selected by an internal jumper, either the trigger signal, or the "A then B" interval, is available on a front-panel trigger output. This can e.g. be routed a counter for time measurement or event counting.  


Tektronix recommended the [[P6131]], 300&nbsp;MHz, 10 MΩ ×10 probe, and the [[P6230]], 1.5 GHz, 450/50 Ω ×10, variable-offset probe for ECL circuits.
The input V/Div setting can only be seen in the mainframe's readout.  There is a jumper to allow the readout to work in a [[7854]] mainframe.
The trigger level is set digitally and shown on a 7-segment display.
 
Tektronix recommended the [[P6131]], 300 MHz, 10 MΩ ×10 probe, and the [[P6230]], 1.5 GHz, 450/50 Ω ×10, variable-offset probe for ECL circuits.


The [[067-1155-99]] calibration fixture is specific to the 7A42.
The [[067-1155-99]] calibration fixture is specific to the 7A42.
Line 60: Line 65:


There is a [[7A42/Repairs|NiCd backup battery]] that allows the unit to retain its last configuration.  
There is a [[7A42/Repairs|NiCd backup battery]] that allows the unit to retain its last configuration.  
A 555 timer implements a 15 ms "real-time clock" and watchdog reset, another drives a beeper.


==See also==
==See also==