3B4: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(moved incorrect reference to a real time adaptor to the 3t4) |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar | | {{Plugin Sidebar | ||
manufacturer=Tektronix |series=560-series scopes |type= 3B4 | | | manufacturer=Tektronix | ||
summary=Time | | series=560-series scopes | ||
designers= | | type=3B4 | ||
image=3b4_front.jpg| | | summary=Time Base Plug-In | ||
caption=3B4 | | designers= | ||
introduced=1964 | | | image=3b4_front.jpg | ||
discontinued=(?) | | | caption=3B4 Front View | ||
manuals= | | introduced=1964 | ||
| discontinued=(?) | |||
| manuals= | |||
* [[Media:070-431.pdf|Tektronix 3B4 Manual]] (PDF) | * [[Media:070-431.pdf|Tektronix 3B4 Manual]] (PDF) | ||
* [http://bama.edebris.com/download/tek/3b4/3b4.djvu Tektronix 3B4 Manual @ BAMA] (DjVu) | * [http://bama.edebris.com/download/tek/3b4/3b4.djvu Tektronix 3B4 Manual @ BAMA] (DjVu) | ||
Line 13: | Line 15: | ||
* [[Media:Tek 3b4 fcp june 1967.pdf|Tektronix 3B4 Factory Calibration Procedure, June 1967]] | * [[Media:Tek 3b4 fcp june 1967.pdf|Tektronix 3B4 Factory Calibration Procedure, June 1967]] | ||
}} | }} | ||
The '''Tektronix Type 3B4''' is a timebase plug-in for [[560-series scopes]], introduced in 1964. | The '''Tektronix Type 3B4''' is a timebase plug-in for [[560-series scopes]], introduced in 1964. | ||
Line 24: | Line 27: | ||
The trigger input is amplified and buffered by a [[6DJ8]]-based differential amplifier driving a common-emitter | The trigger input is amplified and buffered by a [[6DJ8]]-based differential amplifier driving a common-emitter | ||
[[2N964]] germanium PNP transistor whose collector current switches the tunnel diode. | [[2N964]] germanium PNP transistor whose collector current switches the tunnel diode. | ||
{{MissingSpecs}} | {{MissingSpecs}} | ||
Line 35: | Line 36: | ||
<gallery> | <gallery> | ||
3b4_front.jpg| | 3b4_front.jpg| Front View | ||
3b4_left.jpg| | 3b4_left.jpg | Left Side View | ||
3b4_right.jpg| | 3b4_right.jpg| Right Side View | ||
3b4_top.jpg| | 3b4_top.jpg | Top View | ||
</gallery> | </gallery> | ||
{{Parts|3B4}} | {{Parts|3B4}} | ||
[[Category:560 series plugins]] | [[Category:560 series plugins]] |
Revision as of 07:17, 23 November 2023
The Tektronix Type 3B4 is a timebase plug-in for 560-series scopes, introduced in 1964.
It was intended primarily for use with the 561A, but works fine in other 560-series scopes. The 3B4 is unusual in having an explicit "FREE RUN" mode.
In the triggered modes, the tunnel diode-based triggering is rated to work to 20 MHz. The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10 MHz, so 20 MHz is adequate.
Triggering is done with a TD3A 4.7 mA tunnel diode. The trigger input is amplified and buffered by a 6DJ8-based differential amplifier driving a common-emitter 2N964 germanium PNP transistor whose collector current switches the tunnel diode.