7912HB: Difference between revisions
No edit summary |
Tag: Removed redirect |
||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | |||
|manufacturer=Tektronix | |||
|series=7000-series scopes | |||
|model=7912HB | |||
|summary=750 MHz digitizer | |||
|image=Tek 7912hb 1.jpg | |||
|caption=Tektronix 7912HB | |||
|introduced=1988 | |||
|discontinued=1989 | |||
|designers=Carlo Infante;Jim Cavoretto;Al Allworth;Don Roberts;Stu McNaughton;Walt Lowy;Ray Hayes;Ken Hawken;Bob Culter;Hal Cobb;Ed Ritz;Bo Janko | |||
|manuals= | |||
'''7912AD/HB''' | |||
* [[Media:7912ad_theory.pdf | 7912AD Operator's Manual (partial, 57 pages from introduction)]] | |||
* [[Media:7912ad reading gun supply.pdf|7912AD Video preamp/Reading gun supply schematics]] | |||
* [[Media:7912ad writing gun supply.pdf|7912AD Z-Axis/HV board schematics]] | |||
* [[Media:070-5077-00.pdf|Tektronix 7912AD Instrument Interfacing Guide]] | |||
* [[Media:47W-5355.pdf|Tektronix 7912AD Brochure]] | |||
{{ROM Images}} | |||
'''7912AD''' | |||
* U900: [[Media:Tek160-1900-00 8445 U900.BIN|160-1900-00]] | |||
* U1000: [[Media:Tek160-1899-00_8445_U1000.BIN|160-1899-00]] | |||
* U1200: [[Media:Tek160-1901-00_8445_U1200.BIN|160-1901-00]] | |||
'''7912HB'''<br> | |||
''missing, please add'' | |||
}} | |||
The '''Tektronix 7912HB''' is a scan converter based digitizer in the [[7912|7912 series]], [[introduced in 1988]]. | |||
It is an improved version of the previous [[7912AD]], increasing bandwidth to 750 MHz (using a [[7A29P]] amplifier). | |||
For the 7912AD and 7912HB, special GPIB-controllable plug-in modules with a 'P' (Programmable) suffix were available, e.g. [[7A16P]], [[7A29P]] and [[7B90P]]. | |||
The 7912AD was succeeded by the 750 MHz '''7912HB''' in 1987 (using a [[7A29P]] amplifier). | |||
{{MissingSpecs}} | |||
===Options=== | |||
* Option 4: Change to fast digitize mode. This option trades off scan time with resolution by compressing the scan. The target is written on and read from a 256 x 256 point matrix with a maximum of 14 points stored per vertical scan. This option is achieved by setting the correct jumpers on the A16, A20, A22, A26, A46 boards. | |||
* Option 13: Changes the video output to 625 lines/frame with a 50 Hz field rate (PAL). This option is achieved by setting the correct jumpers on the A20 and A28 boards. | |||
==Internals== | |||
Three output methods are provided: Video (NTSC or PAL), X-Y-Z low-speed analog, and a [[GPIB interface]]. For video-out, Tektronix recommended the [[634|634 monitor]] or a monitor from the 650- and 670-series and a 75 Ω termination. For X-Y-Z analog, Tek recommended a 600-series monitor and no specific termination requirement. | |||
==Links== | |||
* [https://www.radiomuseum.org/r/tektronix_7912ad.html Tek 7912AD @ radiomuseum.org] | |||
{{Documents|Link=7912HB}} | |||
==See Also== | |||
* [[R7912]], [[7912AD]] | |||
* [[WP2051]], [[WP2052]] | |||
* [[MP1101]] | |||
* [[SCD1000]], [[SCD5000]] | |||
* [[670-6466-00]] 7912 AD plug-in interface extender | |||
* [[067-0854-00]] Calibration Kit | |||
* [[067-0679-99]] R7912 Demo Unit | |||
==Pictures== | |||
<gallery> | |||
Tek 7912hb 1.jpg|7912HB | |||
Tek 7912hb 2.jpg|7912HB | |||
Tek 7912hb 3.jpg|7912HB | |||
Tek 7912hb 4.jpg|7912HB | |||
</gallery> | |||
==Components== | |||
{{Parts|7912HB}} | |||
[[Category:7000 series digitizer mainframes]] | [[Category:7000 series digitizer mainframes]] | ||
[[Category:Scan converter based instruments]] | |||
[[Category: | [[Category:GPIB interface]] |
Revision as of 04:26, 14 December 2023
The Tektronix 7912HB is a scan converter based digitizer in the 7912 series, introduced in 1988. It is an improved version of the previous 7912AD, increasing bandwidth to 750 MHz (using a 7A29P amplifier).
For the 7912AD and 7912HB, special GPIB-controllable plug-in modules with a 'P' (Programmable) suffix were available, e.g. 7A16P, 7A29P and 7B90P.
The 7912AD was succeeded by the 750 MHz 7912HB in 1987 (using a 7A29P amplifier).
Key Specifications
- please add
Options
- Option 4: Change to fast digitize mode. This option trades off scan time with resolution by compressing the scan. The target is written on and read from a 256 x 256 point matrix with a maximum of 14 points stored per vertical scan. This option is achieved by setting the correct jumpers on the A16, A20, A22, A26, A46 boards.
- Option 13: Changes the video output to 625 lines/frame with a 50 Hz field rate (PAL). This option is achieved by setting the correct jumpers on the A20 and A28 boards.
Internals
Three output methods are provided: Video (NTSC or PAL), X-Y-Z low-speed analog, and a GPIB interface. For video-out, Tektronix recommended the 634 monitor or a monitor from the 650- and 670-series and a 75 Ω termination. For X-Y-Z analog, Tek recommended a 600-series monitor and no specific termination requirement.
Links
Documents Referencing 7912HB
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
SAND94-0784.pdf | Article | Overview of the Instrument Control and Data Reduction Software in the Sandia Data Acquistion System at the Nevada Test Site | William B. Boyer | 1994 | 7912HB • RTD720 • 7103 |
See Also
- R7912, 7912AD
- WP2051, WP2052
- MP1101
- SCD1000, SCD5000
- 670-6466-00 7912 AD plug-in interface extender
- 067-0854-00 Calibration Kit
- 067-0679-99 R7912 Demo Unit
Pictures
-
7912HB
-
7912HB
-
7912HB
-
7912HB