317: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(17 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar  
title=Tektronix 317 |
|manufacturer=Tektronix
summary=10 MHz 3" tube scope|
|series=300-series scopes
image=Tek 317 trace bright.jpg|
|model=317  
caption=Tek 317 |
|summary=10 MHz 3" tube scope
introduced=1959 |
|image=Tek 317 trace bright.jpg
discontinued=1972 |
|caption=Tek 317  
manuals=
|introduced=1959  
* [http://w140.com/mmm/tek-317.pdf Tektronix Type 317 Manual (PDF)]
|discontinued=1972  
* [http://bama.edebris.com/manuals/tek/317/ Tektronix 317 Manual (DJVU, BAMA, offline?)]
|designers=
* [http://w140.com/tek_fcp/tek_type_317_factory_cal_proc.pdf Tektronix 317 Factory Calibration Procedure (PDF)]
|manuals=
* [[Media:070-297.pdf|Tektronix Type 317 Manual]]<br /><small>[https://bama.edebris.com/manuals/tek/317/ Tektronix 317 Manual] (DJVU @ BAMA)</small>
* [[Media:070-325.pdf|Tektronix RM17 Manual]]
 
* [[Media:tek_317_fcp.pdf|Tektronix 317 Factory Calibration Procedure]] (OCR)
* [[Media:Tek 317 fcp dec 1968.pdf|Tektronix 317 Factory Calibration Procedure, Dec. 1968]]
* [[Media:tek_317_irb.pdf|Tektronix 317 Instrument Reference Book]] (OCR)
}}
}}
The '''Tektronix 317''', [[introduced in 1959]], is similar to the [[316]],  
The '''Tektronix 317''', [[introduced in 1959]], is a monolithic 10 MHz scope similar to the [[316]], but with higher acceleration voltage (9 kV versus 1.8 kV) on the CRT.
but with higher acceleration voltage (9 kV versus 1.8 kV) on the CRT.
It was intended for use where a bright display is needed. There is also a rackmount version, the '''RM17'''.
It was intended for use where a bright display is needed.
The 317 initially used [[UHF connector|UHF connectors]] for the signal input and calibrator output;
later units use [[BNC connector|BNC connectors]].
 
There is also a rackmount version, the RM17.


Type 317 MOD 101 operates on 50 to 400 Hz power and uses a DC fan motor.  
The 317 initially used [[UHF connector]]s for the signal input and calibrator output; later units use [[BNC connector]]s.


The 317 uses the [[T317|T317 CRT (154-0346-00)]].
Type 317 Mod 101 operates on 50 to 400 Hz power and uses a DC fan motor.  


==Specifications==
{{BeginSpecs}}
* one vertical channel
{{Spec | Deflection | 0.1 V/div to 50 V/div, 1−2−5, and variable }}
* calibrated vertical deflection factors from 0.1 V/div to 50 V/div
{{Spec | Bandwidth | DC to 10 MHz (50/20/10 mV/div AC only) }}
* DC to 10 MHz frequency response, 35 ns risetime)
{{Spec | Rise time | 35 ns }}
* 0.01 V/div in AC-coupled mode
{{Spec | Input impedance | 1 MΩ // 38 pF }}
* 38 pF input capacitance
{{Spec | Sweep | 200 ns/div to 2 s/div, 1−2−5, and variable }}
* horizontal sweep rates from 2 sec/div to 0.2  μs/div
{{Spec | CRT | [[T317|T317 CRT (154-0346-00)]], 9 kV acceleration}}
{{EndSpecs}}


==Links==
==Links==
Line 35: Line 37:


==Pictures==
==Pictures==
===317===
<gallery>
<gallery>
Tek 317 front.jpg
Tek 317 front.jpg
Line 42: Line 45:
Tek 317 underside.jpg
Tek 317 underside.jpg
Tek 317 rear.jpg
Tek 317 rear.jpg
Tek rm17.jpg|RM17
317 w camera mount.jpg|317 with camera mount
317 w camera mount.jpg|317 with camera mount
Tek 317 early.jpg|early 317 with leather handle
Tek 317 early.jpg|early 317 with leather handle
Line 53: Line 55:
Tek 317 lyons 4.jpg
Tek 317 lyons 4.jpg
Tek 317 lyons 5.jpg
Tek 317 lyons 5.jpg
Tek 317 close trace.jpg|trace
</gallery>
</gallery>
===RM17===
<gallery>
Tek rm17 2.jpg|RM17
Tek rm17 rear.jpg|RM17
Tek rm17.jpg|RM17
Tek rm17 front.jpg|RM17 front
Tek rm17 trace.jpg|RM17 trace
Tek rm17 top.jpg|RM17 top internal
</gallery>
==Components==
{{Parts|317}}


[[Category:Monolithic tube scopes]]
[[Category:Monolithic tube scopes]]

Latest revision as of 10:18, 21 September 2023

Tektronix 317
10 MHz 3" tube scope
Tek 317

Produced from 1959 to 1972

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 317, introduced in 1959, is a monolithic 10 MHz scope similar to the 316, but with higher acceleration voltage (9 kV versus 1.8 kV) on the CRT. It was intended for use where a bright display is needed. There is also a rackmount version, the RM17.

The 317 initially used UHF connectors for the signal input and calibrator output; later units use BNC connectors.

Type 317 Mod 101 operates on 50 to 400 Hz power and uses a DC fan motor.

Key Specifications

Deflection 0.1 V/div to 50 V/div, 1−2−5, and variable
Bandwidth DC to 10 MHz (50/20/10 mV/div AC only)
Rise time 35 ns
Input impedance 1 MΩ // 38 pF
Sweep 200 ns/div to 2 s/div, 1−2−5, and variable
CRT T317 CRT (154-0346-00), 9 kV acceleration

Links

Pictures

317

RM17

Components

Some Parts Used in the 317

Part Part Number(s) Class Description Used in
12AU7 154-041 154-0041-00 154-0287-00 Vacuum Tube (Dual Triode) dual medium-μ triode 104 104A 122 160 161 162 181 190 310 310A 316 317 3C66 502 502A 507 511A 512 516 517 517A 524 526 535 536 545 545A 545B 547 549 555 561 564 570 575 581 581A 585 585A C D E N Q Hickok 1825
12B4 154-044 154-0044-00 Vacuum Tube (Triode) power triode 126 310 310A 316 317 502 502A 524 526 541 541A 535 535A 545 545A 546 547 570 549 551 555 513 581 581A 585 585A Keithley 610
5642 154-0051-00 154-0079-00 Vacuum Tube (Diode) directly-heated high-voltage rectifier 310 310A 316 317 360 453 502 502A 503 504 506 513 515 516 524 529 RM529 533 533A 535 536 543 543A 543B 545 545A 545B 547 551 555 556 560 561 561A 561S 564 567 570 575 581 581A 585 585A 647 647A
6080 154-0056-00 154-0315-00 Vacuum Tube (Dual Triode) dual power triode 132 160 316 317 516 535 535A RM35A 541 541A 535 536 545 545A 545B 546 547 549 565 567 575 581 581A 585 585A
6AL5 154-016 154-0016-00 154-0038-00 Vacuum Tube (Dual Diode) high-perveance dual diode 163 181 190 1M1 310 310A 315 316 317 3B1 3B1S 3B2 3B3 3B5 502 502A 503 511 511A 512 516 517 517A 524 526 535 535A 545 545A 549 551 565 570 581 581A 585 585A C T Telequipment D52 Telequipment D56 Telequipment S52
6AN8 154-078 154-0078-00 Vacuum Tube (Triode/Pentode) triode-pentode combo 310 310A 316 317 360 502 502A 516 517 517A 526 565 570 575 N
6AU6 154-0022-00 157-0073-00 157-0059-00 154-0284-00 Vacuum Tube (Pentode) RF pentode 107 160 181 190 60 2A60 72 3A72 3C66 310 310A 316 317 360 502 502A 506 511 511A 512 513 516 517 517A 524 526 529 RM529 531 531A 535 536 545 545A 546 547 549 555 561 561A 561S 564 565 567 570 575 581 581A 585 585A 80 C CA Q
6CB6A 154-0030-00 Vacuum Tube (Pentode) pentode 105 112 316 317 503 504 513 517 517A 541 535 545 63 2A63
6CL6 154-031 154-0031-00 154-0286-00 Vacuum Tube (Pentode) 7.5 W power pentode 132 310 310A 316 317 515 524 525 531 535 535A 545 545A 545B 549 570 581 581A 585 585A 3A74
6CZ5 154-0167-00 Vacuum Tube (Pentode) power pentode 317 502 506 526 555 561 561A 561S 564 565 567
6DJ8 154-0187-00 154-0305-00 Vacuum Tube (Dual Triode) dual triode 067-506 111 132 161 310A 316 317 502 502A 503 504 506 515 516 519 526 529 RM529 533 535 536 543 544 545 545A 545B 546 547 549 555 556 561A 561S 564 565 567 581 581A 585 585A 661 1A4 1S1 60 2A60 63 2A63 67 2B67 3A1 3A1S 3A2 3A3 3A6 3A7 72 3A72 75 3A75 4S2 51 3B1 3B1S 3B2 3B3 3B4 3M1 3S76 3T77 3T77A 9A1 9A2 1121 80 81 82 86 B O W Z Telequipment D56 Telequipment S32A Telequipment D52 S-311 Telequipment TD51 Telequipment S52 Telequipment S51 Telequipment Type A TU-4
8425 154-0022-07 Vacuum Tube (Pentode) RF pentode 3A72 310A 317 526 Q
T317 154-0196-00 154-0216-00 154-0217-00 154-0218-00 154-0346-00 CRT 3" CRT 317