541: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(27 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar
title=Tektronix 541 |
|manufacturer=Tektronix
summary=30 MHz oscilloscope |
|series=500-series scopes
image=Tek 541.jpg |
|model=541
caption=Tektronix 541 |
|summary=30 MHz oscilloscope
introduced=1955 |
|image=Tek 541.jpg
discontinued=1959 |
|caption=Tektronix 541
manuals=
|introduced=1955
* [http://bama.edebris.com/download/tek/531_541/531_541.djvu Tektronix 531/541 Manual (DjVu)]
|discontinued=1966
* [http://w140.com/mmm/tek-531-541.pdf Tektronix 531/541 Manual (PDF)]
|designers=John Kobbe
* [http://w140.com/tek_541a.pdf Tektronix 541A Manual (PDF)]
|manuals=
* [http://w140.com/tek_fcp/tek_541_fac_cal.pdf Tektronix 541 Factory Calibration Procedure (PDF)]
'''541'''
* [http://w140.com/tek_fcp/tek_541a_fac_cal.pdf Tektronix 541A Factory Calibration Procedure (PDF)]
* [[Media:070-203.pdf|Tektronix 541 Manual 070-203]]
* [http://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier (PDF)]
* [https://bama.edebris.com/download/tek/531_541/531_541.djvu Tektronix 531/541 Manual] (DjVu @ BAMA)
* [http://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope (PDF)]
* [[Media:tek_541_fcp.pdf|Tektronix 541 Factory Calibration Procedure]] (OCR)
'''541A'''
* [[Media:070-154.pdf|Tektronix 541A Manual 070-154]]
* [[Media:tek_541a_fcp.pdf|Tektronix 541A Factory Calibration Procedure]] (OCR)
'''Common'''
* [[Media:tek_balancing_545_vertical.pdf|Balancing the 540-Series Vertical Amplifier]] (OCR)
* [[Media:tek_adjust_540_vertical.pdf|How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope]] (OCR)
* [[Media:Tek 500-series modification summary.pdf|Modification Summary for 541 and Similar Models]] (PDF scan from faded printout)
}}
}}
The '''Tektronix Type 541''' is a 30 MHz* oscilloscope that accepts [[letter-series and 1-series plug-ins]].
The '''Tektronix Type 541''' is a 30 MHz* oscilloscope that accepts [[letter-series and 1-series plug-ins]].
It has a [[distributed amplifier]] and is exactly like the Type [[545]]  
It has a [[distributed amplifier]] and is exactly like the Type [[545]] except it does not have the Delayed Sweep (dual timebase) feature.
except it does not have the Delayed Sweep (dual timebase) feature.


It was [[introduced in 1955]] simultaneously with the 545,  
It was [[introduced in 1955]] simultaneously with the [[545]], and was superseded in [[introduced_in_1959|1959]] by the 541A, which has more convenient controls.
and was superseded in [[introduced_in_1959|1959]] by the 541A,
For example, the 541 required the operator to set two rotary switches to get the desired sweep time/div.
which has more convenient controls.
The 541A replaced the two-switch design with a many-position rotary switch.
This was also the case with setting the calibrator amplitude, which involved two switches on the 541 and one switch on the 541A.


The 541's CRT is part number [[154-098]], also known as the T54.  
The 541's CRT is part number [[154-098]], also known as the T54.  
The standard [[phosphor]] is P2.  The 541A uses the [[T65]] CRT.
The standard [[phosphor]] is P2.  The 541A uses the [[T65]] CRT.
[[John Kobbe]] designed the 541 and contributed to the design of its CRT,
realizing that there is a tradeoff between scan height and bandwidth.
This is why the pre-B 540-series scopes have only four cm vertical deflection.
There is a rackmount version, Type RM41.


There is also a 541-S7 version, which has single-sweep mode.
There is also a 541-S7 version, which has single-sweep mode.


==Specifications==
A new probe, the [[P410|P400 Series]], was created for the 541/545, because the 10 MHz [[P510|P510A]] rings on fast signals.


{{MissingSpecs}}
<nowiki>*</nowiki> 33 MHz with a 50 MHz plug-in such as the Type [[1A1]].
<nowiki>*</nowiki> 33 MHz with a 50 MHz plug-in such as the Type [[1A1]].


Line 40: Line 54:
Tek 541 5100 left.jpg|541 left internal
Tek 541 5100 left.jpg|541 left internal
Tek 541 5100 right.jpg|541 right internal
Tek 541 5100 right.jpg|541 right internal
Tek 541a trace.jpg|541A trace
Tek 541a trace2.jpg|541A trace
</gallery>
</gallery>


{{Parts|541}}
{{Parts|541A}}
{{Parts|RM41}}


[[Category:500 series scopes]]
[[Category:500 series scopes]]
[[Category:Specifications needed]]

Latest revision as of 12:10, 12 July 2024

Tektronix 541
30 MHz oscilloscope
Tektronix 541

Produced from 1955 to 1966

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type 541 is a 30 MHz* oscilloscope that accepts letter-series and 1-series plug-ins. It has a distributed amplifier and is exactly like the Type 545 except it does not have the Delayed Sweep (dual timebase) feature.

It was introduced in 1955 simultaneously with the 545, and was superseded in 1959 by the 541A, which has more convenient controls. For example, the 541 required the operator to set two rotary switches to get the desired sweep time/div. The 541A replaced the two-switch design with a many-position rotary switch. This was also the case with setting the calibrator amplitude, which involved two switches on the 541 and one switch on the 541A.

The 541's CRT is part number 154-098, also known as the T54. The standard phosphor is P2. The 541A uses the T65 CRT.

John Kobbe designed the 541 and contributed to the design of its CRT, realizing that there is a tradeoff between scan height and bandwidth. This is why the pre-B 540-series scopes have only four cm vertical deflection.

There is a rackmount version, Type RM41.

There is also a 541-S7 version, which has single-sweep mode.

A new probe, the P400 Series, was created for the 541/545, because the 10 MHz P510A rings on fast signals.

Key Specifications

  • please add

* 33 MHz with a 50 MHz plug-in such as the Type 1A1.

Pictures


Some Parts Used in the 541

Part Part Number(s) Class Description Used in
12B4 154-044 154-0044-00 Vacuum Tube (Triode) power triode 126 310 310A 316 317 502 502A 524 526 541 541A 535 535A 545 545A 546 547 570 549 551 555 513 581 581A 585 585A Keithley 610
12BY7A 154-047 154-0047-00 Vacuum Tube (Pentode) miniature 6.5 W power pentode 106 163 524 531 533 535 536 541 543 535 545 545A 549 555 75 3A75 3B5
5651 154-052 154-0052-00 154-0288-00 Gas Discharge Tube (Voltage regulator) 87 V voltage reference 128 160 310 310A 502 503 504 511A 512 516 517 524 526 531 531A 535 536 541 541A 543 543A 543B 545 545A 545B 570 549 581 581A 585 585A
5BHP 154-0142-00 154-152 154-0409-00 154-409 154-0106-00 154-106 154-0098-00 154-098 154-0099-00 154-099 154-0104-00 154-104 CRT 5" CRT 541 545
6080 154-0056-00 154-0315-00 Vacuum Tube (Dual Triode) dual power triode 132 160 316 317 516 535 535A RM35A 541 541A 535 536 545 545A 545B 546 547 549 565 567 575 581 581A 585 585A
6AU5 154-021 154-0021-00 Vacuum Tube (Pentode) 10 W beam power pentode 507 513 516 517 517A 531 535 541 535 545 547 581 581A 585 585A
6AW8 154-0095-00 Vacuum Tube (Triode/Pentode) triode-pentode combo 132 160 541 535 545
6BQ7A 154-028 154-0028-00 157-0022-00 157-0003-00 Vacuum Tube (Dual Triode) dual triode 107 163 181 310 315 316 360 524 531 532 535 536 541 545 570 T
6CB6A 154-0030-00 Vacuum Tube (Pentode) pentode 105 112 316 317 503 504 513 517 517A 541 535 545 63 2A63
6DK6 154-0149-00 154-0367-00 Vacuum Tube (Pentode) high-frequency miniature pentode 180 503 513 514 541 543 535 545 545A 551 555
T54 154-0098-00 154-0099-00 154-0104-00 154-0105-00 154-0106-00 154-0142-00 CRT CRT 541 545


Some Parts Used in the 541A

Part Part Number(s) Class Description Used in
12B4 154-044 154-0044-00 Vacuum Tube (Triode) power triode 126 310 310A 316 317 502 502A 524 526 541 541A 535 535A 545 545A 546 547 570 549 551 555 513 581 581A 585 585A Keithley 610
5651 154-052 154-0052-00 154-0288-00 Gas Discharge Tube (Voltage regulator) 87 V voltage reference 128 160 310 310A 502 503 504 511A 512 516 517 524 526 531 531A 535 536 541 541A 543 543A 543B 545 545A 545B 570 549 581 581A 585 585A
6080 154-0056-00 154-0315-00 Vacuum Tube (Dual Triode) dual power triode 132 160 316 317 516 535 535A RM35A 541 541A 535 536 545 545A 545B 546 547 549 565 567 575 581 581A 585 585A
T5430 154-0175-00 154-0758-00 154-0758-03 154-0758-04 154-0183-00 CRT 5" CRT 541A 543 543A 545A


Some Parts Used in the RM41