SC501: Difference between revisions
Jump to navigation
Jump to search
(headline) |
No edit summary |
||
(19 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type= | {{TM500 | mfg=Tektronix | type=SC501 | function=5 MHz oscilloscope | class=oscilloscope | image=Tek sc501 front.jpg | introduced=1975 | discontinued=1993 | | ||
manuals= | designers= |manuals= | ||
* [ | * [[Media:070-1700-00.pdf|Tektronix SC501 Manual]] | ||
* [[Media:TB-9-6625-2173-35.pdf|US Army Calbration Guide for SC501, SC502, and SC504]] | |||
}} | }} | ||
The SC501 uses the [[155-0055-00]] (U200) for trigger and sweep. | |||
The [[MR501]] X-Y monitor shares part of the SC501's design. | |||
The CRT cathode is directly heated and at −980 V. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 9: | Line 15: | ||
{{Spec|Sweep|1 μs/Div to 100 ms/Div in decade steps, plus variable control and ×5 magnifier (200 ns/Div to 1 s/Div overall)}} | {{Spec|Sweep|1 μs/Div to 100 ms/Div in decade steps, plus variable control and ×5 magnifier (200 ns/Div to 1 s/Div overall)}} | ||
{{Spec|Input impedance|1 MΩ // 47 pF}} | {{Spec|Input impedance|1 MΩ // 47 pF}} | ||
{{Spec| | {{Spec| CRT | 6 × 10 divisions of 0.203" (5.16 mm) i.e. 1.2" × 2" (31 mm × 51.5 mm), [[154-0699-00]] tube}} | ||
{{Spec|Features| | {{Spec|Features| | ||
* X-Y mode | * X-Y mode (Internal switch to activate, X input via 2 mm jack) | ||
* external trigger input | * external trigger input (2 mm jack) | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | |||
{{Documents|Link=SC501}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek_sc501_front.jpg | |||
Tek sc501.jpg | |||
SC501w-blue_fliter.jpg|SC 501 with blue CRT filter | |||
Tek sc501 9 1.jpg | |||
Tek sc501 9 2.jpg | |||
Tek sc501 9 3.jpg | |||
Tek sc501 9 4.jpg | |||
Tek sc501 9 5.jpg | |||
Tek sc501 9 6.jpg | |||
Tek sc501 tm501.jpg | |||
Tek sc501 vertical schematic.jpg|Vertical schematic | |||
Tek sc501 horizontal.png|Horizontal schematic | |||
Tek sc501 low voltage supplies.jpg|Low Voltage Supplies schematic | |||
Tek sc501 z axis and crt schematic.jpg|Z-Axis and CRT schematic | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|SC501}} |
Latest revision as of 08:16, 19 November 2023
The Tektronix SC501 is a 5 MHz oscilloscope plug-in for the TM500 system.
The SC501 uses the 155-0055-00 (U200) for trigger and sweep.
The MR501 X-Y monitor shares part of the SC501's design.
The CRT cathode is directly heated and at −980 V.
Key Specifications
Bandwidth | 5 MHz |
---|---|
Deflection | 10 mV/Div, 100 mV/Div, 1 V/Div, plus variable control (10 mV/Div to 10 V/Div overall) |
Sweep | 1 μs/Div to 100 ms/Div in decade steps, plus variable control and ×5 magnifier (200 ns/Div to 1 s/Div overall) |
Input impedance | 1 MΩ // 47 pF |
CRT | 6 × 10 divisions of 0.203" (5.16 mm) i.e. 1.2" × 2" (31 mm × 51.5 mm), 154-0699-00 tube |
Features |
|
Links
Documents Referencing SC501
Pictures
-
-
-
SC 501 with blue CRT filter
-
-
-
-
-
-
-
-
Vertical schematic
-
Horizontal schematic
-
Low Voltage Supplies schematic
-
Z-Axis and CRT schematic
Components
Some Parts Used in the SC501
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0699-00 | 154-0699-00 • 154-0699-50 | CRT | directly-heated CRT for miniature scopes | 211 • 212 • SC501 |
155-0048-01 | 155-0048-00 • 155-0048-01 • 155-0055-00 • 155-0055-01 | Monolithic integrated circuit | trigger sweep | 211 • 212 • 213 • 214 • 432 • 433 • 5B12N • 5B13N • 5L4N • 603 • 604 • 605 • 606 • 606A • 607 • 624 • SC501 • R7912 |
2N3958 | 151-1054-00 • 151-1054-01 • 151-1054-02 | Discrete component | dual n-channel JFET | FG503 • MR501 • M3 • PG505 • SC501 • SC502 • SC503 • SG502 • 1450 • 1501 • 1502 • 1503 • 221 • 5A23N • 5CT1N • 577 • 603 • 603A • 604 • 604A • 605 • 606 • 606A • 606B • 607 • 607A • 620 • 624 • 7CT1N • 7D15 • 7D20 • 851 |