3S2: Difference between revisions
Jump to navigation
Jump to search
m (→top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=) |
No edit summary |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar| | {{Plugin Sidebar | ||
manufacturer=Tektronix |series=560-series scopes |type= 3S2 | | |manufacturer=Tektronix | ||
summary=Dual trace sampling | |series=560-series scopes | ||
image=3s2_front.JPG | | |type= 3S2 | ||
caption= | |summary=Dual-trace sampling plug-in | ||
designers= | |image=3s2_front.JPG | ||
introduced=1967 | | |caption=Tektronix 3S2 Front View | ||
discontinued=1975 | | |designers= | ||
manuals= | |introduced=1967 | ||
|discontinued=1975 | |||
|manuals= | |||
* [[Media:070-0759-00.pdf|3S2 Manual]] | * [[Media:070-0759-00.pdf|3S2 Manual]] | ||
}} | }} | ||
The '''Tektronix 3S2''' is a dual-trace [[sampling oscilloscope|sampling plug-in]] for [[560-series scopes]]. | |||
The '''Tektronix | |||
It takes two [[7000 and 3S series sampling heads]] such as the [[S-1]], [[S-2]], [[S-3]], [[S-4]], [[S-5]], or [[S-6]]. | It takes two [[7000 and 3S series sampling heads]] such as the [[S-1]], [[S-2]], [[S-3]], [[S-4]], [[S-5]], or [[S-6]]. | ||
Line 18: | Line 19: | ||
The 3S2 uses a [[BSM connector]] for the trigger output on the front panel. | The 3S2 uses a [[BSM connector]] for the trigger output on the front panel. | ||
== | {{MissingSpecs}} | ||
==Links== | |||
{{Documents|Link=3S2}} | |||
{{PatentLinks|3S2}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
3s2_front.JPG| | 3s2_front.JPG|Front View | ||
3s2_left.JPG| | 3s2_left.JPG |Left View | ||
3s2_right.JPG| | 3s2_right.JPG|Right View | ||
3s2_top.JPG| | 3s2_top.JPG |Top View | ||
3s2_bottom.JPG| | 3s2_bottom.JPG|Bottom View | ||
3s2_rear.JPG| | 3s2_rear.JPG |Rear View | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|3S2}} | |||
[[Category:Sampling plugins]] | [[Category:Sampling plugins]] | ||
[[Category:560 series plugins]] | [[Category:560 series plugins]] |
Latest revision as of 12:00, 19 June 2024
The Tektronix 3S2 is a dual-trace sampling plug-in for 560-series scopes. It takes two 7000 and 3S series sampling heads such as the S-1, S-2, S-3, S-4, S-5, or S-6.
Bandwidth and sensitivity are determined by the sampling heads, not the 3S2.
The 3S2 uses a BSM connector for the trigger output on the front panel.
Key Specifications
- please add
Links
Documents Referencing 3S2
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Service Scope 52 Oct 1968.pdf | Article | The State of the Art in Sampling | Al Zimmerman | 1968 | S-1 • S-2 • S-3 • S-4 • S-50 • S-51 • 285 • 3S1 • 3S2 • 3S5 • 3S6 • 3T2 • 3T5 • 3T6 • 3T77A • 568 • 230 |
Pictures
-
Front View
-
Left View
-
Right View
-
Top View
-
Bottom View
-
Rear View
Components
Some Parts Used in the 3S2
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
151-0261-00 | 151-0261-00 | Discrete component | dual PNP transistor | AM501 • AM502 • CG5001 • CG551AP • FG501 • FG502 • FG503 • OF150 • OF151 • OF152 • OF235 • OS261 • RM502A • R1140 • R5030 • R5031 • R7912 • 067-0679-00 • 067-0807-00 • 1101 • 1140A • 1141 • 1142 • 1350 • 145 • 1450 • 1480 • 1481 • 1482 • 1485 • 1501 • 1801 • 1900 • 1910 • 1980 • 213 • 26A1 • 26A2 • 2620 • 285 • 3A9 • 3A10 • 3S1 • 3S2 • 3S5 • 3S6 • 432 • 434 • 4501 • 454 • 4601 • 4602 • 4610 • 4612 • 4620 • 4632 • 4634 • 4701 • 475 • 492 • 492A • 492AP • 494 • 494P • 496 • 496P • 5A13N • 5A20N • 5A21N • 5A22N • 5A26 • 5L4N • 502A • 5030 • 5031 • 576 • 690SR • 7A22 • 7A29 • 7B51 • 7B71 • 7J20 • 7L5 • 7S11 • 7S12 • 7912AD |