454: Difference between revisions
No edit summary |
(removed dead link) |
||
Line 10: | Line 10: | ||
|discontinued=1974 | |discontinued=1974 | ||
|manuals= | |manuals= | ||
* [[Media:070-0617-00.pdf|Tektronix 454 Manual]] | '''454''' | ||
* [ | * [[Media:070-0617-00.pdf|Tektronix 454 Manual]] | ||
* [[Media:070-1074-00.pdf|Tektronix 454A Manual (unstitched color schematics, OCR | * [[Media:070-0617-00_2.pdf|Tektronix 454 Manual]] (whole schematics, no OCR) | ||
* [ | '''454A''' | ||
* [[Media:Tek 454 eis no ocr.pdf|Tektronix 454 Engineering Instrument Specification ( | * [[Media:070-1074-00.pdf|Tektronix 454A Manual]] (unstitched color schematics, OCR) | ||
* [[Media:Tek 454 fcp jan 1968.pdf|Tektronix 454 Factory Calibration Procedure, January 1968 ( | * [[Media:070-1106-00.pdf|Tektronix 454A Operators Handbook]] (OCR) | ||
* [[Media:Tek 454 cal outline.pdf|Tektronix 454 Calibration Outline ( | <small> | ||
* [[Media:Tek 454 aberration spec.pdf|Tektronix 454 Aberration Specification ( | '''Specs, Calibration''' | ||
* [[Media:Tek 454 eis no ocr.pdf|Tektronix 454 Engineering Instrument Specification]] (needs OCR) | |||
* [[Media:Tek 454 fcp jan 1968.pdf|Tektronix 454 Factory Calibration Procedure, January 1968]] (needs OCR) | |||
* [[Media:Tek 454 cal outline.pdf|Tektronix 454 Calibration Outline]] (OCR) | |||
* [[Media:Tek 454 aberration spec.pdf|Tektronix 454 Aberration Specification]] (OCR) | |||
</small> | |||
}} | }} | ||
The '''Tektronix 454''' is a 150 MHz portable dual-trace scope [[introduced in 1967|introduced in March 1967]]. | The '''Tektronix 454''' is a 150 MHz portable dual-trace scope [[introduced in 1967|introduced in March 1967]]. | ||
It can be seen as an improved [[453]]. The successor 454A was [[introduced in 1971]]. | It can be seen as an improved [[453]]. The successor 454A was [[introduced in 1971]]. | ||
The 454 is the fastest general-purpose Tektronix scope that does not use proprietary hybrid | The 454 is the fastest general-purpose Tektronix scope that does not use proprietary hybrid or integrated circuits. | ||
or integrated circuits. | It uses a CRT with [[distributed vertical deflection plates]]. | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 454A - 150 MHz (100 MHz @ 5 mV/div, 50 MHz @ 2 mV/div) }} | |||
{{Spec | Deflection | 5 mV/div to 10 V/div, 1−2−5 }} | |||
{{Spec | CRT | [[T4540]], P31 [[phosphor]] standard / P11 optional; +12/–1.96 kV acceleration }} | |||
{{Spec | Weight | 13 kg / 29 lb }} | |||
{{Spec | Power | 90–136/180−272 V, 48−440 Hz, 100–145 W }} | |||
{{EndSpecs}} | |||
It is possible to cascade the Ch1/Ch2 input amplifiers to obtain a sensitivity of 400 μV/div at a bandwidth of 33 MHz. | |||
The 454 has two ±12 V probe power outputs for [[P6045]] probes. | |||
The 454 | |||
==Internals== | ==Internals== | ||
The 454 has a 140 ns [[delay line]] in the signal path after the | The 454 has a 140 ns [[delay line]] in the signal path after the input channel switching and before the main vertical amplifier. | ||
input channel switching and before the main vertical amplifier. | There is a phase equalizer after the delay line to mitigate the harm done to pulse fidelity by the delay line. | ||
There is a phase equalizer after the delay line to mitigate the | |||
harm done to pulse fidelity by the delay line | |||
==454 Modifications== | ==454 Modifications== | ||
The 454 came in several different modifiactions that were indicated on the field on the frontplate directly below the "454" lettering, left of the serial number field. Known modifications are | The 454 came in several different modifiactions that were indicated on the field on the frontplate directly below the "454" lettering, left of the serial number field. Known modifications are | ||
* MOD163D | * MOD163D | ||
* MOD210N - [[P6047]] accessory probes come in | * MOD210N - [[P6047]] accessory probes come in 6 ft variant with extra accessories. | ||
==Pictures== | ==Pictures== | ||
'''454''' | |||
<gallery> | <gallery> | ||
Line 72: | Line 69: | ||
454 vert out.gif | 454 vert out.gif | ||
</gallery> | </gallery> | ||
'''454A''' | |||
<gallery> | <gallery> | ||
Tek 454a sine square.jpg | Tek 454a sine square.jpg | ||
Line 83: | Line 81: | ||
{{Parts|454}} | {{Parts|454}} | ||
{{Parts|454A}} | |||
Revision as of 03:22, 8 August 2023
The Tektronix 454 is a 150 MHz portable dual-trace scope introduced in March 1967. It can be seen as an improved 453. The successor 454A was introduced in 1971.
The 454 is the fastest general-purpose Tektronix scope that does not use proprietary hybrid or integrated circuits. It uses a CRT with distributed vertical deflection plates.
Key Specifications
Bandwidth | 454A - 150 MHz (100 MHz @ 5 mV/div, 50 MHz @ 2 mV/div) |
---|---|
Deflection | 5 mV/div to 10 V/div, 1−2−5 |
CRT | T4540, P31 phosphor standard / P11 optional; +12/–1.96 kV acceleration |
Weight | 13 kg / 29 lb |
Power | 90–136/180−272 V, 48−440 Hz, 100–145 W |
It is possible to cascade the Ch1/Ch2 input amplifiers to obtain a sensitivity of 400 μV/div at a bandwidth of 33 MHz.
The 454 has two ±12 V probe power outputs for P6045 probes.
Internals
The 454 has a 140 ns delay line in the signal path after the input channel switching and before the main vertical amplifier. There is a phase equalizer after the delay line to mitigate the harm done to pulse fidelity by the delay line.
454 Modifications
The 454 came in several different modifiactions that were indicated on the field on the frontplate directly below the "454" lettering, left of the serial number field. Known modifications are
- MOD163D
- MOD210N - P6047 accessory probes come in 6 ft variant with extra accessories.
Pictures
454
-
454 with traces
-
-
'A' intensified during 'B' mode
-
454 with P11-CRT
-
-
-
-
-
-
-
454A
-
-
454A Front
-
454A Bottom
-
454A Vertical amp
-
454A Top
Some Parts Used in the 454
Some Parts Used in the 454A
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
155-0400-00 | 155-0400-00 | Hybrid integrated circuit | vertical amplifier | 454A |
STD910 | 152-0310-00 | Discrete component | 5 mA, 7 pF tunnel diode | 454 • 454A |