7B52: Difference between revisions
mNo edit summary |
No edit summary |
||
Line 15: | Line 15: | ||
It was designed for the [[7503]] mainframe but is compatible with the entire series. | It was designed for the [[7503]] mainframe but is compatible with the entire series. | ||
The 7B52 was only produced for about two years early in the 7000 series life cycle and is therefore quite rare. | The 7B52 was only produced for about two years early in the 7000 series life cycle and is therefore quite rare. | ||
It was superseded in 1973 by the very similar [[7B53A]] which had the mode selection integrated into the time/Div switch, | |||
and the combined trigger level/polarity control replaced with separate, concentric knobs. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 37: | Line 39: | ||
==Links== | ==Links== | ||
* http://www.barrytech.com/tektronix/tek7000/tek7b52.html | * http://www.barrytech.com/tektronix/tek7000/tek7b52.html | ||
Line 52: | Line 53: | ||
Tek 7b52 1.jpg | Tek 7b52 1.jpg | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|7B52}} | |||
[[Category:7000 series horizontal plugins]] | [[Category:7000 series horizontal plugins]] |
Revision as of 13:01, 6 October 2023
The Tektronix 7B52 is a 100 MHz dual time base plug-in for 7000-series scopes. It was designed for the 7503 mainframe but is compatible with the entire series.
The 7B52 was only produced for about two years early in the 7000 series life cycle and is therefore quite rare. It was superseded in 1973 by the very similar 7B53A which had the mode selection integrated into the time/Div switch, and the combined trigger level/polarity control replaced with separate, concentric knobs.
Key Specifications
Sweep rates | 50 ns/Div to 5 s/Div in 1−2−5 sequence |
---|---|
Deflection | 10 mV/Div, 100 mV/Div or 1 V/Div, up to 2 MHz |
Sensitivity | 0.3 Div or 150 mV up to 10 MHz, 1.5 Div or 750 mV up to 100 MHz |
Coupling | DC, AC (> 30 Hz), AC LF REJ (> 30 kHz), AC HF REJ (30 Hz — 50 kHz) |
Input impedance | 1 MΩ // 20 pF |
Jitter | < 1 ns at 75 MHz |
Features |
|
Operation
The 7B52 supports X−Y mode through the "Amplifier" setting of the Time/Div switch. The Trigger Source determines whether the X signal is taken from a verical plug-in via the internal trigger path or from the external trigger input.
A switch accessible through the side panel allows the user to select the delayed timebase trigger input − either the main trigger signal on pins A20/B20, or an auxiliary trigger signal supplied via pins A21/B21. The 7403N and 7503 mainframes supply the Left Vertical trigger signal on these pins. It is not known if other mainframes supply this signal, and the 7B52 is the only plug-in known to access this signal. (Any information welcome!)
Links
Pictures
-
Front view
-
Left side with sweep board
-
Right side with trigger & readout boards
-
Right cover of 7B52
-
-
-
-
-