<!-- * [[Media:Tek 547 544 546 technical instruction and training.pdf|Tektronix 547, 546, and 544 Technical Instruction and Training (PDF, needs OCR)]] --> | <!-- * [[Media:Tek 547 544 546 technical instruction and training.pdf|Tektronix 547, 546, and 544 Technical Instruction and Training (PDF, needs OCR)]] --> | ||
* [http://w140.com/Hi-speed_recorder.pdf General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF)] | * [http://w140.com/Hi-speed_recorder.pdf General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF)] |
Revision as of 08:15, 7 December 2023
The Tektronix Type 544 is a 50 MHz scope introduced in 1964.
It has one timebase with several horizontal magnifier modes (×2, ×5, ×10, ×20, ×50, and ×100). To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the regular horizontal position control. The fastest calibrated sweep is 10 ns/div. Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that.
The 544 (at least the early ones) uses the same tunnel diode triggering circuit as is used in early 547 (tunnel diode in the collector load of a PNP differential amplifier).
There is also a rackmount version, the RM544.
The standard 544 and standard RM544 has a total CRT accelerating voltage of 10 kV. A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV.
The 1968 catalog lists an RM544 Mod 720A which comes a package with a direct-access plug-in. The Mod 720A system has 1 ns risetime (equiv. 350 MHz).
The vertical amplifier and low voltage power supply of the 544 are the same as those of the 546 and 547. The 544 uses the 154-0478-00 CRT which is also used by the 543B, 545B, 546, and 547.
The project lead for the development of the Tektronix 544, 546, and 547 was Bob Rullman.
Key Specifications
- please add
Pictures
-
-
544 Front view
-
544 Left Internal
-
544 Right Internal
-
544 with Type G plug-in, front view
-
-
-
-
-
-
-
-
-
-
-
RM544
-
RM544 with 1A1 plug-in, front view
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in