516: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(35 intermediate revisions by 4 users not shown)
Line 1: Line 1:
The Tektronix Type 516 is a monolithic 15MHz dual-trace oscilloscope introduced in 1960.   
{{Oscilloscope Sidebar
It contains no transistors.  It uses [[turret attenuators]].
|manufacturer=Tektronix
|series=
|model=516
|summary=15 MHz dual-trace scope
|image=Tek 516 front.jpg
|caption=Tektronix 516
|introduced=1960
|discontinued=1972
|designers=
|manuals=
* [[Media:070-0225-01.pdf|Tektronix 516 Manual]] (OCR)
<small>
'''Alternate'''
* [https://bama.edebris.com/download/tek/516/516.djvu Tektronix 516 Manual] (DjVu @ BAMA)
* [https://bama.edebris.com/download/tek/516/516.pdf Tektronix 516 Manual] (PDF @ BAMA)
}}
The '''Tektronix Type 516''' is a monolithic 15 MHz dual-trace oscilloscope [[introduced in 1960]], essentially a dual trace version of the [[515]].  It contains no transistors
 
{{MissingSpecs}}
 
==Internals==
The main difference between the 515 and 516 is the front end - the 515 uses a conventional rotary switch for the input attenuator while the 516 uses [[turret attenuators]]. 
 
There are also some differences in the vertical amplifier circuitry. 
The 515 uses a [[6AU6]] pentode at the front end.
The 516 uses a [[6DJ8]] dual triode at the front end, and in many other places throughout the instrument.
 
In a 516, the [[delay line]] directly drives the vertical deflection plates of the CRT.
 
The standard CRT is the [[T55]] with P31 [[phosphor]].   
It has a post-deflection acceleration voltage of +2,335 V. The CRT cathode runs at –1,675 V.
The HV power supply uses three [[5642]] rectifier tubes:
* V822 for the CRT cathode voltage
* V832 for the CRT control grid voltage
* V842 for the post-deflection voltage
 
The LV power supply is typical of 1960's Tek scopes. It provides:
* +400 V unregulated
* +300 V regulated, using one triode of a [[6080]] as the output tube
* +100 V regulated, using one triode of a 6080 as the output tube
* –150 V regulated, using a [[6AU5]] tube as the output tube
The reference for the LV supply is a [[5651]] which produces a –87 V reference, which controls the –150 V supply. 
The –150 V supply is used as the reference for the +100 V and +300 V supplies.
The LV power supply uses the [[120-142]] power transformer.
 
==Pictures==
===External===
<gallery>
Tek 516 trace.jpg
Tek 516 front.jpg
Tek 516 controls.jpg
Tek 516 rear.jpg
Tek 516 ael.JPG
Tek 516 right.jpg
Tek 516 top.jpg
Tek 516 left.jpg
Tek 516 front whole.jpg
Tek 516 front upper.jpg
Tek 516 front lower.jpg
Tek_516_rear2.jpg|Rear
Tek 516 rear3.jpg
</gallery>
 
===Internals===
<gallery>
Tek 516 turret.jpg|turret attenuator
Tek 516 bottom rear.jpg|Bottom, toward rear
Tek 516 front end.jpg|Attenuators and front-end
Tek 516 front right.jpg|Right front, sweep rate switch
Tek_516_hvps1.jpg|HV power supply
Tek_516_left_front_top.jpg|Right front
Tek 516 left rear.jpg|Left rear, delay line, LV regulator tubes
Tek 516 left top.jpg|Left top
Tek 516 neck pins.jpg|CRT neck pins
Tek 516 rear right.jpg|Rear right, transformer, filter caps, fan
Tek 516 right top.jpg|Right top
Tek 516 bottom front2.jpg|Bottom, toward front
</gallery>
 
===Schematics===
<gallery>
516hvps.png|HV power supply schematic
516lvps.png|LV power supply schematic
516vert.png|Vertical input amplifier schematic
516vertout and delay.png|Vertical output schematic
516 trigger.png|Trigger schematic
516 timebase.png|Timebase schematic
516 horizontal.png|Horizontal amplifier schematic
</gallery>
 
==Components==
{{Parts|516}}
 
[[Category:Monolithic tube scopes]]

Latest revision as of 10:56, 21 September 2023

Tektronix 516
15 MHz dual-trace scope
Tektronix 516

Produced from 1960 to 1972

Manuals

Alternate

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix Type 516 is a monolithic 15 MHz dual-trace oscilloscope introduced in 1960, essentially a dual trace version of the 515. It contains no transistors.

Key Specifications

  • please add

Internals

The main difference between the 515 and 516 is the front end - the 515 uses a conventional rotary switch for the input attenuator while the 516 uses turret attenuators.

There are also some differences in the vertical amplifier circuitry. The 515 uses a 6AU6 pentode at the front end. The 516 uses a 6DJ8 dual triode at the front end, and in many other places throughout the instrument.

In a 516, the delay line directly drives the vertical deflection plates of the CRT.

The standard CRT is the T55 with P31 phosphor. It has a post-deflection acceleration voltage of +2,335 V. The CRT cathode runs at –1,675 V. The HV power supply uses three 5642 rectifier tubes:

  • V822 for the CRT cathode voltage
  • V832 for the CRT control grid voltage
  • V842 for the post-deflection voltage

The LV power supply is typical of 1960's Tek scopes. It provides:

  • +400 V unregulated
  • +300 V regulated, using one triode of a 6080 as the output tube
  • +100 V regulated, using one triode of a 6080 as the output tube
  • –150 V regulated, using a 6AU5 tube as the output tube

The reference for the LV supply is a 5651 which produces a –87 V reference, which controls the –150 V supply. The –150 V supply is used as the reference for the +100 V and +300 V supplies. The LV power supply uses the 120-142 power transformer.

Pictures

External

Internals

Schematics

Components

Some Parts Used in the 516

Part Part Number(s) Class Description Used in
120-142 120-142 Discrete component power transformer 515A 516
12AT7 154-0039-00 Vacuum Tube (Dual Triode) dual high-gain triode 161 180 310 310A 315 316 360 502 502A 511A 512 513 513D 514 514AD 514D 516 524 529 RM529 544 546 547 556 565 570 3A2 75 3A75 1M1 A B C G H K L ML M N K R S Z Keithley 610B
12AU7 154-041 154-0041-00 154-0287-00 Vacuum Tube (Dual Triode) dual medium-μ triode 104 104A 122 160 161 162 181 190 310 310A 316 317 3C66 502 502A 507 511A 512 516 517 517A 524 526 535 536 545 545A 545B 547 549 555 561 564 570 575 581 581A 585 585A C D E N Q Hickok 1825
154-0764-00 154-0764-00 154-0764-03 154-0764-04 CRT CRT 515A RM15 516
5642 154-0051-00 154-0079-00 Vacuum Tube (Diode) directly-heated high-voltage rectifier 310 310A 316 317 360 453 502 502A 503 504 506 513 515 516 524 529 RM529 533 533A 535 536 543 543A 543B 545 545A 545B 547 551 555 556 560 561 561A 561S 564 567 570 575 581 581A 585 585A 647 647A
5651 154-052 154-0052-00 154-0288-00 Gas Discharge Tube (Voltage regulator) 87 V voltage reference 128 160 310 310A 502 503 504 511A 512 516 517 524 526 531 531A 535 536 541 541A 543 543A 543B 545 545A 545B 570 549 581 581A 585 585A
6080 154-0056-00 154-0315-00 Vacuum Tube (Dual Triode) dual power triode 132 160 316 317 516 535 535A RM35A 541 541A 535 536 545 545A 545B 546 547 549 565 567 575 581 581A 585 585A
6197 154-0146-00 Vacuum Tube (Pentode) 7.5 W power pentode 516 531 533 535 535A 547 556 75 3A75
6AL5 154-016 154-0016-00 154-0038-00 Vacuum Tube (Dual Diode) high-perveance dual diode 163 181 190 1M1 310 310A 315 316 317 3B1 3B1S 3B2 3B3 3B5 502 502A 503 511 511A 512 516 517 517A 524 526 535 535A 545 545A 549 551 565 570 581 581A 585 585A C T Telequipment D52 Telequipment D56 Telequipment S52
6AN8 154-078 154-0078-00 Vacuum Tube (Triode/Pentode) triode-pentode combo 310 310A 316 317 360 502 502A 516 517 517A 526 565 570 575 N
6AU5 154-021 154-0021-00 Vacuum Tube (Pentode) 10 W beam power pentode 507 513 516 517 517A 531 535 541 535 545 547 581 581A 585 585A
6AU6 154-0022-00 157-0073-00 157-0059-00 154-0284-00 Vacuum Tube (Pentode) RF pentode 107 160 181 190 60 2A60 72 3A72 3C66 310 310A 316 317 360 502 502A 506 511 511A 512 513 516 517 517A 524 526 529 RM529 531 531A 535 536 545 545A 546 547 549 555 561 561A 561S 564 565 567 570 575 581 581A 585 585A 80 C CA Q
6BL8 154-0278-00 Vacuum Tube (Triode/Pentode) triode-pentode combo 67 2B67 3B1 3B1S 3B2 3B3 3B4 503 504 506 516 549 561 561A 561S 564 565 567 Telequipment D52 Telequipment D56 Telequipment S31 Telequipment S32 Telequipment S32A Telequipment S51 Telequipment S52
6DJ8 154-0187-00 154-0305-00 Vacuum Tube (Dual Triode) dual triode 067-506 111 132 161 310A 316 317 502 502A 503 504 506 515 516 519 526 529 RM529 533 535 536 543 544 545 545A 545B 546 547 549 555 556 561A 561S 564 565 567 581 581A 585 585A 661 1A4 1S1 60 2A60 63 2A63 67 2B67 3A1 3A1S 3A2 3A3 3A6 3A7 72 3A72 75 3A75 4S2 51 3B1 3B1S 3B2 3B3 3B4 3M1 3S76 3T77 3T77A 9A1 9A2 1121 80 81 82 86 B O W Z Telequipment D56 Telequipment S32A Telequipment D52 S-311 Telequipment TD51 Telequipment S52 Telequipment S51 Telequipment Type A TU-4
6GM8 154-259 154-0259-00 Vacuum Tube (Dual Triode) dual triode 81 516 S
7119 154-0340-00 Vacuum Tube (Dual Triode) dual triode 067-506 067-0532-00 191 3A3 3B4 3B5 516 545B 549 661 Chemtrix 205
T0550 154-344 154-0344-00 CRT CRT 515 515A 516
T55 154-0344-00 CRT CRT 515 515A 516