A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV. | A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV. | ||
The 1968 catalog lists an RM544 Mod 720A which comes a package with a [[500-Series Direct Access Plug-in Unit|direct-access plug-in]] | The 1968 catalog lists an RM544 Mod 720A which comes a package with a [[500-Series Direct Access Plug-in Unit|direct-access plug-in]] and selectable 12 kV/24 kV acceleration voltage, to achieve 1 ns risetime (equiv. 350 MHz) at 12.5 V/div sensitivity and 2000 cm/μs photographic recording speed. | ||
==Links== | ==Links== |
Latest revision as of 02:09, 27 October 2024
The Tektronix Type 544 is a 50 MHz scope introduced in 1964.
It has one timebase with several horizontal magnifier modes (×2, ×5, ×10, ×20, ×50, and ×100). To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the regular horizontal position control. The fastest calibrated sweep is 10 ns/div.
Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that.
The project lead for the development of the Tektronix 544, 546, and 547 was Bob Rullman. The team also included Keith Taylor, John Gates, Gene Kauffman, and George Smith.
There is also a rackmount version, the RM544.
Key Specifications
- please add
The standard 544 and standard RM544 has a total CRT accelerating voltage of 10 kV. A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV.
The 1968 catalog lists an RM544 Mod 720A which comes a package with a direct-access plug-in and selectable 12 kV/24 kV acceleration voltage, to achieve 1 ns risetime (equiv. 350 MHz) at 12.5 V/div sensitivity and 2000 cm/μs photographic recording speed.
Links
Documents Referencing 544
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Martzloff High-speed Recording System.pdf | Article | High-Speed Transient Recording System | François Martzloff | 1968 | 544 • 1A1 |
Internals
The vertical amplifier and low voltage power supply of the 544 are the same as those of the 546 and 547. The 544 uses the 154-0478-00 CRT which is also used by the 543B, 545B, 546, and 547.
The 544 (at least the early ones) uses the same tunnel diode triggering circuit as is used in early 547 (tunnel diode in the collector load of a PNP differential amplifier).
Pictures
-
-
544 Front view
-
544 Left Internal
-
544 Right Internal
-
544 with Type G plug-in, front view
-
-
-
-
-
-
-
-
-
-
-
RM544
-
RM544 with 1A1 plug-in, front view
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in
-
RM544 with Type L plug-in