{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
summary=Portable 150/300 MHz 4-ch scope | | |series=2400-series scopes | ||
image=tek2465.jpg | | |model=2465 | ||
caption=Tektronix 2465 | | |summary=Portable 150/300 MHz 4-ch scope | ||
introduced=1984 | | |image=tek2465.jpg | ||
discontinued=(?) | | |caption=Tektronix 2465 | ||
manuals= | |introduced=1984 | ||
* [[Media:070- | |discontinued=(?) | ||
* [[Media:070-3829-00.pdf | 2445 Service]] (OCR | |designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth; Wink Gross; Mike Metcalf; Marv LaVoie; | ||
* [[Media:070- | |manuals= | ||
* [[Media:070-3831-00.pdf|2465 Service]] ( | '''2445''' | ||
* [[Media:070-3830-00.pdf|2445 Operator]] (OCR, 17M) | |||
* [[Media:070- | * [[Media:070-3829-00.pdf|2445 Service, January 1983 Edition]] (OCR, 27M) | ||
* [[Media:070-4182-00.pdf|Opt.01 DMM Service]] (OCR | '''2465''' | ||
* [[Media:070-4366-00.pdf|24x5 Rack-mount Kit]] (OCR | * [[Media:070-3832-00.pdf|070-3832-00 2465 Operator]] (OCR, 22M) | ||
* [[Media:070-3831-00.pdf|070-3831-00 2465 Service]] (29M) / [[Media:070-3831-00_plus_chg.pdf|070-3831-00 + changes]] (OCR, 20M) | |||
'''Common''' | |||
* [[Media:070-6863-01.pdf|Tektronix 2465B & 2467B Service Manual]] | |||
* [[Media:070-4180-00.pdf|2445/2465 Quick Start]] (OCR, 2.5M) | |||
* [[Media:070-4182-00.pdf|Opt.01 DMM Service]] (OCR, 11M) | |||
* [[Media:070-4183-00.pdf|Opt.01 DMM Operators]] | |||
* [[Media:070-4366-00.pdf|24x5 Rack-mount Kit]] (OCR, 6M) | |||
* [[Media:070-4629-00.pdf|Opt.05 TV Operator]] | * [[Media:070-4629-00.pdf|Opt.05 TV Operator]] | ||
* [[Media:070-4630-00.pdf|Opt.05 TV Service]] | * [[Media:070-4630-00.pdf|Opt.05 TV Service]] | ||
* [[Media:070-4631-00.pdf|Opt.06 Opt.09 CTT/WR Operator]] | * [[Media:070-4631-00.pdf|Opt.06 Opt.09 CTT/WR Operator]] | ||
* [[Media:070-4632-00.pdf|Opt.06 Opt.09 CTT/WR Service]] | * [[Media:070-4632-00.pdf|Opt.06 Opt.09 CTT/WR Service]] | ||
* [[Media:070-4633-00.pdf|Opt.10 GPIB Operator]] (OCR | * [[Media:070-4633-00.pdf|Opt.10 GPIB Operator]] (OCR, 9M) | ||
* [[Media:070-4640-00.pdf|Opt.10 GPIB Service]] (OCR | * [[Media:070-4640-00.pdf|Opt.10 GPIB Service]] (OCR, 23M) | ||
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit | * [[Media:070-5150-00.pdf|Opt.10 Instrument Interfacing Guide]] | ||
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit]] | |||
{{ROM Images}} | |||
}} | }} | ||
The '''Tektronix 2465''' is a four-channel 300 MHz portable oscilloscope from the penultimate generation of analog Tektronix scopes. The '''2445''' is a 150 MHz version. ''See [[2465A]] and [[2465B]] for the successor versions.'' | |||
[[Wink Gross]] was the vertical system engineer for the 2465. He designed the [[2465]] main vertical amplifier, the channel switch, and the auxiliary input preamp. | |||
[[Marv LaVoie]] designed the 2465 attenuator. | |||
The horizontal amplifier in the 2465 was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. | The horizontal amplifier in the 2465 was designed by [[Art Metz]] and [[Ken Schlotzhauer]] ([[155-0239-00|trigger IC]]). Art Metz also worked on the triggers. He and [[Walt Ainsworth]] designed the sweeps. | ||
Art Metz also worked on the triggers. | [[Mike Metcalf]] designed the 2465 [[155-0242-00|Z axis IC]], both under the direction of [[Art Metz]]. | ||
He and [[Walt Ainsworth]] designed the sweeps. | Art had horizontal system responsibility and designed the non-IC part of the horizontal as well. | ||
'''Options''' | '''Options''' | ||
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature. | * Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature. | ||
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering. | * Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering. A knob and an on-screen numerical display allows selection of a line number to be displayed. If the scope is in mixed time base mode, an intensified region is shown in the field rate display. | ||
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering. | * Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering. | ||
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]]. | * Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]]. | ||
* Option 10 added a [[GPIB interface]] for remote control. | * Option 10 added a [[GPIB interface]] for remote control. | ||
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 350 MHz (2445: 150 MHz) }} | |||
{{Spec | Sweep | 5 ns/Div to 500 ms/Div, 1−2−5, and ×10 magnifier (fastest sweep 500 ps/Div) }} | |||
{{Spec | Bandwidth | 350 MHz | |||
{{Spec | Sweep | |||
{{Spec | Channels | Four independent channels }} | {{Spec | Channels | Four independent channels }} | ||
{{Spec | | {{Spec | Deflection | 2 mV/div to 5 V/Div, 1−2−5 }} | ||
{{Spec | Cursors | Delta Volts and Delta Time Cursors }} | {{Spec | Cursors | Delta Volts and Delta Time Cursors }} | ||
{{Spec | CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators }} | {{Spec | CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators }} | ||
{{Spec | Trigger | Advanced Triggering with "Hands Off" Auto Level Triggering }} | {{Spec | Trigger | Advanced Triggering with "Hands Off" Auto Level Triggering }} | ||
{{Spec | | {{Spec | Trigger Bandwidth | 500 MHz min. }} | ||
{{Spec | Input Impedance| 50 Ω/1 MΩ inputs with 50 Ω protection }} | {{Spec | Input Impedance| 50 Ω / 1 MΩ inputs with 50 Ω protection }} | ||
{{Spec | CRT | [[154-0850-01]] }} | {{Spec | CRT | [[154-0850-01]], +14/−1.9 kV }} | ||
{{Spec | Probes | Two [[P6131]] ×10 probes, 1.3 m }} | {{Spec | Probes | Two [[P6131]] ×10 probes, 1.3 m }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Line 58: | Line 66: | ||
* [[2465A]] | * [[2465A]] | ||
* [[2465B]] | * [[2465B]] | ||
==Links== | ==Links== | ||
* [ | * [https://www.tek.com/support/faqs/how-do-you-run-self-tests-2465 How to enter test mode] | ||
* [http://www.kerrywong.com/2016/02/22/teardown-of-a-tektronix-2465/ Teardown of a Tektronix 2465] @ kerrywong.com | |||
* [https://hackaday.io/project/163890-tektronix-2465-series-servicing 2465 series servicing] @ hackaday.io | * [https://hackaday.io/project/163890-tektronix-2465-series-servicing 2465 series servicing] @ hackaday.io | ||
* [https://www.youtube.com/watch?v=Rks_AyfJNq4 Tektronix 2445 Oscilloscope Repair] by NFM @ YouTube | |||
{{Documents|Link=2465}} | |||
{{PatentLinks|2465}} | |||
{{Documents|Link=2465A}} | |||
{{PatentLinks|2465A}} | |||
{{Documents|Link=2465B}} | |||
{{PatentLinks|2465B}} | |||
==Prices== | |||
'''2465''' | |||
{| class="wikitable" | |||
|- | |||
! Year | |||
! 1984 | |||
! 1986 | |||
|- | |||
! Catalog Price | |||
|align=right| | |||
|align=right| $5,350 | |||
|- | |||
! In 2023 Dollars | |||
|align=right| | |||
|align=right| $15,000 | |||
|} | |||
'''2445''' | |||
{| class="wikitable" | |||
|- | |||
! Year | |||
! 1984 | |||
! 1986 | |||
|- | |||
! Catalog Price | |||
|align=right| | |||
|align=right| $3,590 | |||
|- | |||
! In 2023 Dollars | |||
|align=right| | |||
|align=right| $10,100 | |||
|} | |||
==Pictures== | ==Pictures== | ||
Line 70: | Line 118: | ||
USA Tektronix 2445 Front0.jpg | USA Tektronix 2445 Front0.jpg | ||
Tek 2445 with dmm.jpg | Tek 2445 with dmm.jpg | ||
Tek knobless 2445.jpg|Prototype Knobless 2445 in VintageTEK Museum | Tek knobless 2445.jpg | Prototype Knobless 2445 in VintageTEK Museum | ||
</gallery> | </gallery> | ||
Line 83: | Line 131: | ||
2465(3).jpg | 2465(3).jpg | ||
2465(4).jpg | 2465(4).jpg | ||
Tek 2465 rear.jpg | Rear with Opt 11 probe power | |||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|2445}} | |||
{{Parts|2465}} | |||
[[Category:246x series scopes]] | [[Category:246x series scopes]] | ||
[[Category:Introduced in 1984]] | [[Category:Introduced in 1984]] |
Latest revision as of 05:03, 26 June 2024
The Tektronix 2465 is a four-channel 300 MHz portable oscilloscope from the penultimate generation of analog Tektronix scopes. The 2445 is a 150 MHz version. See 2465A and 2465B for the successor versions.
Wink Gross was the vertical system engineer for the 2465. He designed the 2465 main vertical amplifier, the channel switch, and the auxiliary input preamp. Marv LaVoie designed the 2465 attenuator. The horizontal amplifier in the 2465 was designed by Art Metz and Ken Schlotzhauer (trigger IC). Art Metz also worked on the triggers. He and Walt Ainsworth designed the sweeps. Mike Metcalf designed the 2465 Z axis IC, both under the direction of Art Metz. Art had horizontal system responsibility and designed the non-IC part of the horizontal as well.
Options
- Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
- Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering. A knob and an on-screen numerical display allows selection of a line number to be displayed. If the scope is in mixed time base mode, an intensified region is shown in the field rate display.
- Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
- Option 09 added option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
- Option 10 added a GPIB interface for remote control.
- Option 11 added two probe-power connectors on the rear panel of the instrument.
Key Specifications
Bandwidth | 350 MHz (2445: 150 MHz) |
---|---|
Sweep | 5 ns/Div to 500 ms/Div, 1−2−5, and ×10 magnifier (fastest sweep 500 ps/Div) |
Channels | Four independent channels |
Deflection | 2 mV/div to 5 V/Div, 1−2−5 |
Cursors | Delta Volts and Delta Time Cursors |
CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators |
Trigger | Advanced Triggering with "Hands Off" Auto Level Triggering |
Trigger Bandwidth | 500 MHz min. |
Input Impedance | 50 Ω / 1 MΩ inputs with 50 Ω protection |
CRT | 154-0850-01, +14/−1.9 kV |
Probes | Two P6131 ×10 probes, 1.3 m |
See also
Links
- How to enter test mode
- Teardown of a Tektronix 2465 @ kerrywong.com
- 2465 series servicing @ hackaday.io
- Tektronix 2445 Oscilloscope Repair by NFM @ YouTube
Documents Referencing 2465
- (no results)
Patents that may apply to 2465
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 4146844A | Feed-forward amplifier | Pat Quinn | 1977-10-31 | 1979-03-27 | Cascomp • 2465 |
Patent US 4705961A | Programmable sweep generator | Walt Ainsworth • Art Metz | 1986-01-21 | 1987-11-10 | 155-0240-00 • 2445 • 2465 • 2465A • 2465B • 2467 • 2467B • 11302A • SCD1000 |
Documents Referencing 2465A
- (no results)
Patents that may apply to 2465A
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 4705961A | Programmable sweep generator | Walt Ainsworth • Art Metz | 1986-01-21 | 1987-11-10 | 155-0240-00 • 2445 • 2465 • 2465A • 2465B • 2467 • 2467B • 11302A • SCD1000 |
Documents Referencing 2465B
- (no results)
Patents that may apply to 2465B
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 4705961A | Programmable sweep generator | Walt Ainsworth • Art Metz | 1986-01-21 | 1987-11-10 | 155-0240-00 • 2445 • 2465 • 2465A • 2465B • 2467 • 2467B • 11302A • SCD1000 |
Prices
2465
Year | 1984 | 1986 |
---|---|---|
Catalog Price | $5,350 | |
In 2023 Dollars | $15,000 |
2445
Year | 1984 | 1986 |
---|---|---|
Catalog Price | $3,590 | |
In 2023 Dollars | $10,100 |
Pictures
2445
-
-
-
-
Prototype Knobless 2445 in VintageTEK Museum
2465
-
-
-
-
-
-
-
-
-
Rear with Opt 11 probe power
Components
Some Parts Used in the 2445