The '''DC 502 Digital Counter''' is a plug-in for the [[TM500]] mainframe series that measures frequencies from 10 Hz to 550 MHz or totalizes events up to the readout capacity of 10<sup>7</sup>-1 at the maximum rate of 550 MHz.
{{TM500
 
|mfg=Tektronix
==Specifications==
|type=DC502
 
|function=550 MHz frequency counter
* Direct Counting to 110 MHz
|class=counter
* 7 Digit LED Display
|image=Tek dc502 opt1 1.jpg
* Manual Start/Stop (Totalize)
|introduced=1972
* Gate times: 0.01 s, 0.1 s, 1.0 s, and 10 s
|discontinued=1977
* DIRECT INPUT:
|designers=Jim Geddes
** Frequency range: 10 Hz to 110 MHz
|manuals=
** Input impedance: 1 MΩ
* [[Media:070-1412-00.pdf|Tektronix DC502 Instruction Manual 070-1412-00]] (OCR)
** Sensitivity: 300 mV<sub>p-p</sub> (100 mV<sub>rms</sub> sine wave)
* [[Media:050-1276-00.pdf|DC501, DC502, DC503 Service Note 050-1276-00]]
** adjustable trigger level range
}}
* &divide;10 PRESCALE INPUT:
It measures frequencies from 10 Hz to 550 MHz or totalizes events up to the readout capacity of 10<sup>7</sup>−1 at the maximum rate of 550 MHz.
** Frequency range: 50 MHz to 550 MHz
** Sensitivity: 500 mV<sub>p-p</sub> (170 mV<sub>rms</sub> sine wave)
** Input impedance: 50 &Omega;


{{BeginSpecs}}
{{Spec|Resolution      | 7 digits}}
{{Spec|Frequency range | 10 Hz to 110 MHz (Direct input); 50 MHz to 550 MHz (÷10 input) }}
{{Spec|Sensitivity    | 300 mV<sub>p-p</sub> or 100 mV<sub>rms</sub> sine (Direct input); 500 mV<sub>p-p</sub> or 170 mV<sub>rms</sub> sine (÷10 input) }}
{{Spec|Input impedance | 1 MΩ (Direct input); 50 Ω (÷10 input) }}
{{Spec|Gate time      | 0.01 s, 0.1 s, 1.0 s, or 10 s }}
{{Spec|Stability      | 1×10<sup>−5</sup> (10 ppm) standard, 5×10<sup>−7</sup> (0.5 ppm) with Opt.01}}
{{Spec|Features|
* 7-digit LED Display, automatic decimal point and leading zero blanking
* manual Start/Stop (Totalize)
* adjustable trigger level on direct input
}}
{{Spec|Options|
* Opt.01 – TCXO
* Opt.07 – to display [[SW503]] marker ([[Media:Tekscope_1976_V8_N1.pdf|Tekscope V.8 N.1 p.20]] and [[Media:070-2051-00.pdf|070-2051-00 p. 5-3]] – more information needed)
}}
{{EndSpecs}}
The manual totalizing mode with front panel start stop control is available in both inputs; from the prescale input, 1 displayed count per 10 input events will result.
The manual totalizing mode with front panel start stop control is available in both inputs; from the prescale input, 1 displayed count per 10 input events will result.
Measurement display is accomplished with 7 segment LEDs in a seven digit readout. The decimal point is automatically positioned by the measurement interval selected, and leading zeroes (those to the left of the most sig digit or those to the left of the decimal point) are blanked.


LEDs indicate when the gate is armed, and whether displayed numbers are in kHz or MHz, and when register overflow occurs.  
LEDs indicate when the gate is armed, and whether displayed numbers are in kHz or MHz, and when register overflow occurs.  


A standard internal 1 MHz clock is provided with 1 &times; 10<sup>-5</sup> (10 ppm) accuracy.
The internal clock is 1 MHz. The Opt.05 high stability oscillator runs at 5 MHz with an additional by-5 divider.


==Links==
==Links==
{{Documents|Link=DC502}}
{{PatentLinks|DC502}}


* http://www.barrytech.com/tektronix/tektm500/tekdc502.html
==Rear Interface==
<small>
{| class="wikitable"
|-
! Connector Pin
! Signal
|-
| 28B      || Second decimal point output
|-
| 27B      || MHz light output
|-
| 27A      || Internal Scan Clock Disable
|-
| 26A      || /RESET
|-
| 25B      || External Scan Clock input
|-
| 25A      || Time Slot Zero
|-
| 24B      || Internal Scan Clock output (2 kHz)
|-
| 23B      || Overflow
|-
| 22B      || MSD output
|-
| 21B      || BCD output 2
|-
| 20B      || BCD output 8
|-
| 20A      || BCD output 4
|-
| 19A      || BCD output 1
|-
| 19B      || Data Good
|}
Data is output serially by digit.
</small>


==Pictures==
==Pictures==
<gallery>
<gallery>
File:Tek dc502 opt1 1.jpg
Tek dc502 opt1 1.jpg
File:Tek dc502 opt1 2.jpg
Tek dc502 opt1 2.jpg
File:Tek dc502 opt1 3.jpg
Tek dc502 opt1 3.jpg
Tek sw503 dc502 sg504 dc508a mr501 tm515.png|DC502 in [[TM515]] with other TM500 gear
</gallery>
</gallery>
==Components==
{{Parts|DC502}}


[[Category:TM500 counter plugins]]
[[Category:TM500 counter plugins]]
[[Category:Frequency counters]]
[[Category:Frequency counters]]
[[Category:Manual needed]]

Latest revision as of 04:54, 6 October 2024

Tektronix DC502
550 MHz frequency counter
Tektronix DC502

Produced from 1972 to 1977

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix DC502 is a 550 MHz frequency counter plug-in for the TM500 system.

It measures frequencies from 10 Hz to 550 MHz or totalizes events up to the readout capacity of 107−1 at the maximum rate of 550 MHz.

Key Specifications

Resolution 7 digits
Frequency range 10 Hz to 110 MHz (Direct input); 50 MHz to 550 MHz (÷10 input)
Sensitivity 300 mVp-p or 100 mVrms sine (Direct input); 500 mVp-p or 170 mVrms sine (÷10 input)
Input impedance 1 MΩ (Direct input); 50 Ω (÷10 input)
Gate time 0.01 s, 0.1 s, 1.0 s, or 10 s
Stability 1×10−5 (10 ppm) standard, 5×10−7 (0.5 ppm) with Opt.01
Features
  • 7-digit LED Display, automatic decimal point and leading zero blanking
  • manual Start/Stop (Totalize)
  • adjustable trigger level on direct input
Options

The manual totalizing mode with front panel start stop control is available in both inputs; from the prescale input, 1 displayed count per 10 input events will result.

LEDs indicate when the gate is armed, and whether displayed numbers are in kHz or MHz, and when register overflow occurs.

The internal clock is 1 MHz. The Opt.05 high stability oscillator runs at 5 MHz with an additional by-5 divider.

Links

Documents Referencing DC502

Document Class Title Authors Year Links
Tekscope 1972 V4 N3 May 1972.pdf Article TM500 series - A New Dimension in Plug-in Instrumentation Bob Ragsdale 1972
070-2088-00.pdf Book TM500 Series Rear Interface Data Book 1975
070-2088-01.pdf Book TM500 Series Rear Interface Data Book 1976
070-2088-04.pdf Book TM500 Series Rear Interface Data Book 1985

Patents that may apply to DC502

Page Title Inventors Filing date Grant date Links
Patent US 3562464A Cam actuated switch having movable and fixed contacts on circuit board Howard Vollum Willem H Verhoef Tony Sprando 1968-10-07 1971-02-09

Rear Interface

Connector Pin Signal
28B Second decimal point output
27B MHz light output
27A Internal Scan Clock Disable
26A /RESET
25B External Scan Clock input
25A Time Slot Zero
24B Internal Scan Clock output (2 kHz)
23B Overflow
22B MSD output
21B BCD output 2
20B BCD output 8
20A BCD output 4
19A BCD output 1
19B Data Good

Data is output serially by digit.

Pictures

Components

Some Parts Used in the DC502

Part Part Number(s) Class Description Used in
2N4249 151-0342-00 Discrete component PNP Si low noise amp. DC501 DC502 DC503 DC503A DC504 DC504A DC505 DC505A DC508 DC508A DC509 DC510
2N4851 151-0504-00 151-0504-01 Discrete component silicon unijunction transistor DC501 DC502 DC503 DC503A DC504 DC505 DC505A DC508 DC508A LA501 R1330 212 214 4002A 4623 4631 4632 4633A 4634 4701 4701R 670-0696-01 670-1274-00 670-1981-00 670-1981-01 7D01 7D12 7L12