567: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (Tidy up manuals. Note re incompatible plugins)
 
(19 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar
title=Tektronix 567 |
|manufacturer=Tektronix
summary=Sampling scope |
|series=560-series scopes
image=567 front.jpg |
|model=567  
caption=Tektronix 567 front |
|summary=Sampling scope  
introduced=1962 |
|image=567 front.jpg  
discontinued=1972 |
|caption=Tektronix 567 front  
manuals=
|introduced=1962  
* [http://bama.edebris.com/download/tek/567/tek%20567.v6.pdf Tektronix 567 Manual (PDF)]
|discontinued=1972  
* [http://w140.com/4499749_tek567.pdf Materials Characterization Application of 567 (PDF)]
|designers=Sam McCutcheon
* [http://w140.com/tek_567_1968_catalog.pdf Tektronix 567 in 1968 Catalog (PDF)]
|manuals=
* [http://w140.com/tek_readout_oscilloscopes_1968_catalog.pdf "Digital Readout Introduction" in 1968 Catalog (PDF)]
* [[Media:070-0322-01.pdf                                         | Tektronix 567 Manual]]
* [[Media:Tek digital readout oscilloscope and programmer.pdf|Digital Readout Oscilloscope and Programmer]]
* [[Media:070-348.pdf                                             | Tektronix RM567 Manual]]
* [https://w140.com/tek_567_1968_catalog.pdf                       Tektronix 567 in 1968 Catalog]
* [https://w140.com/tek_readout_oscilloscopes_1968_catalog.pdf     "Digital Readout Introduction" in 1968 Catalog]
* [[Media:Tek digital readout oscilloscope and programmer.pdf     | Digital Readout Oscilloscope and Programmer]]
* [[Media:Tek 6R1A and system calibration.pdf                    | Tektronix 6R1A and System Calibration]]
* [[Media:Tek 567 cal outline.pdf                                | Tektronix 567 Calibration Outline]]
* [https://w140.com/4499749_tek567.pdf                              Materials Characterization Application of 567]
}}
}}
The '''Tektronix 567''' is a [[sampling oscilloscope]] mainframe [[introduced in 1962]].   
The '''Tektronix 567''' is a [[sampling oscilloscope]] mainframe [[introduced in 1962]].   


It has a digital plug-in unit, the [[6R1]] or [[6R1A]], that can be used to measure  
It has a digital plug-in unit, the [[6R1]] or [[6R1A]], that can be used to measure waveform characteristics such as rise time.   
waveform characteristics such as rise time.  This digital unit provides a go/no-go output  
This digital unit provides a go/no-go output based on waveform characteristics.   
based on waveform characteristics.  This feature makes the 567 particularly useful in  
This feature makes the 567 particularly useful in production testing for tasks such as binning logic gates based on their speed.   
production testing for tasks such as binning logic gates based on their speed.   
 
The development of the 567 (and 6R1) was led by [[Sam McCutcheon]].


The 567 came after the [[661]] and before the [[568]] and its associated [[230]] Digital Unit.
The 567 came after the [[661]] and before the [[568]] and its associated [[230]] Digital Unit.


According to [[Stan Griffiths]],
The 567 is a self-contained oscilloscope, but is also used as a component of S2000- and
<blockquote>
S3000-series measurement systems. In that capacity, it typically uses one of the programmable
It looks like there were two different serial number runs of 567's.
plug-ins, [[S-311]], [[S-300]], or [[S-301]].


Bench models:
{{MissingSpecs}}
* 000101-000750 = 650 instruments
* 002000-003280 = 1280 instruments
* Total = 1930
 
Rackmount models:
* 000101-000228 = 128 instruments
* 002000-002240 = 240 instruments
* Total = 368
 
Grand Total = approx. 2300
</blockquote>


==Operation==
The 567 has three plug-in compartments.   
The 567 has three plug-in compartments.   
The left compartment holds a 3S-series sampling vertical unit such as a [[3S2]].   
The left compartment holds a 3S-series sampling vertical unit such as a [[3S2]].   
The center compartment holds a 3T-series sampling sweep unit such as a [[3T77]].
The center compartment holds a 3T-series sampling sweep unit such as a [[3T77]].
The right compartment holds the digital unit, either a [[6R1]] or a [[6R1A]].
The right compartment holds the digital unit, either a [[6R1]] or a [[6R1A]].
It is possible to operate a 567 without the digital unit but
It is possible to operate a 567 without the digital unit but in that configuration it provides only the functionality that a [[561]] provides.
in that configuration it provides only the functionality that a [[561]] provides.


The [[6R1]] and [[6R1A]] digital units have several different operating
The [[6R1]] and [[6R1A]] digital units have several different operating modes.   
modes.  These modes can be classified as time measurement or
These modes can be classified as time measurement or voltage measurement.   
voltage measurement.  One time measurement mode, for example,  
One time measurement mode, for example, shows the time delay between the rising pulse edge on input A and the falling pulse edge on input B.   
shows the time delay between the rising pulse edge on input A  
This is useful for measuring the speed of a logic gate such as an inverter.   
and the falling pulse edge on input B.  This is useful for measuring
One of the voltage measurement modes displays the difference between the input A voltage at on time and the input A voltage at some other time.   
the speed of a logic gate such as an inverter.  One of the voltage
This is useful for measuring the peak-to-peak amplitude of a signal.
measurement modes displays the difference between the input A voltage
at on time and the input A voltage at some other time.  This is
useful for measuring the peak-to-peak amplitude of a signal.


The mechanisms used by the digital unit are a sample and hold circuit,
==Internals==
a comparator, a counter, and a switched tap voltage divider.   
The mechanisms used by the digital unit are a sample and hold circuit, a comparator, a counter, and a switched tap voltage divider.   
The digital unit takes its input from the vertical signal produced by the sampling unit.
The digital unit takes its input from the vertical signal produced by the sampling unit.
Therefore, it operates on a low-speed signal,  
Therefore, it operates on a low-speed signal, somewhat similar to the intermediate frequency (IF) in a superheterodyne radio.   
somewhat similar to the intermediate frequency (IF) in a superheterodyne radio.   


The user of the 567 positions two cursors along the X-axis.
The user of the 567 positions two cursors along the X-axis.
These cursors define two times and two voltages.   
These cursors define two times and two voltages.   
The tapped voltage divider produces several voltages
The tapped voltage divider produces several voltages along the interval spanned by the two cursor voltages 10%, 20%, 27%, 50%, 73%, 80%, and 90%.
along the interval spanned by the two cursor voltages:
10%, 20%, 27%, 50%, 73%, 80%, and 90%.
These voltages are used for making measurements such as the 10%-to-90% rise time.   
These voltages are used for making measurements such as the 10%-to-90% rise time.   
In this case, a counter is reset and started when the signal passes through the 10% voltage.   
In this case, a counter is reset and started when the signal passes through the 10% voltage.   
The counter counts the number of cycles of a built-in crystal clock.
The counter counts the number of cycles of a built-in crystal clock.
When the signal reaches the 90% voltage,
When the signal reaches the 90% voltage, the counter is stopped and the count is displayed on the [[nixie tube]] digital numeric readout.
the counter is stopped and the count is displayed on the [[nixie tube]] digital numeric readout.
The units and decimal place of the digital unit are controlled by switch contacts on the timing unit plug-in,
The units and decimal place of the
digital unit are controlled by switch contacts on the timing unit plug-in,
which connect to the digital unit through a multi-pin connector in the 567.   
which connect to the digital unit through a multi-pin connector in the 567.   


The 567 does not have any post-deflection acceleration of the beam.
The 567 does not have any post-deflection acceleration of the beam.
The CRT circuit uses two [[5642]] high-voltage rectifier tubes, one (V822)
The CRT circuit uses two [[5642]] high-voltage rectifier tubes, one (V822)
to generate the CRT cathode voltage (-3,300 V) and one (V832) to generate the CRT
to generate the CRT cathode voltage (−3.3 kV) and one (V832) to generate the CRT
grid bias voltage.  CRTs used were [[T5032]] (earlier) and [[T5611]] (later models).
grid bias voltage.  CRTs used were [[T5032]] (earlier) and [[T5611]] (later models).


A 567 can be perform remotely controlled measurements by connecting a [[262]]
A 567 can perform remotely controlled measurements by connecting a [[262]]
programmer to the [[6R1]] or [[6R1A]] that is in the 567.
programmer to the [[6R1]] or [[6R1A]] that is in the 567.


Line 87: Line 75:
to be operated outside the plug-in bay of the 567 for maintenance purposes.
to be operated outside the plug-in bay of the 567 for maintenance purposes.


The 567 is a self-contained oscilloscope, but is also used as a component of S2000- and
==Models==
S3000-series measurement systems. In that capacity, it typically uses one of the programmable
 
plug-ins: [[S-311]], [[S-300]], and [[S-301]].
According to [[Stan Griffiths]],
<blockquote>
It looks like there were two different serial number runs of 567's.
 
Bench models:
* 000101-000750 = 650 instruments
* 002000-003280 = 1280 instruments
* Total = 1930
 
Rackmount models:  
* 000101-000228 = 128 instruments
* 002000-002240 = 240 instruments
* Total = 368
 
Grand Total = approx. 2300
</blockquote>


{{MissingSpecs}}
==See Also==
* [[Patent US 3359491A | US Patent #3359491: Signal Waveform Characteristic Measuring System Having Stop Start Logic Circuit]], Sam McCutcheon, 1962


==Pictures==
==Pictures==


<gallery>
<gallery>
567_front.jpg|Front view, w 6R1A digital unit
567_front.jpg                       | Front view, w 6R1A digital unit
567_front_6r1.jpg | Front view, w 6R1 digital unit
567_front_6r1.jpg                   | Front view, w 6R1 digital unit
RM567_w_6R1A.JPG | Front view of RM567 w 6R1A digital unit
RM567_w_6R1A.JPG                   | Front view of RM567 w 6R1A digital unit
Tek_567_introduction2.jpg|576 Introduction in 1962 Catalog
567 front with 6R1A.jpg            | 567 with 6R1A (and random incompatible plugins!)
Tek_567_introduction2.jpg           | 576 Introduction in 1962 Catalog
Tek567-3s76-3t77.jpg
Tek567-3s76-3t77.jpg
Tek 567 ps top.jpg|Top view power supply.  Blue capacitors are not original.
567 top view inside original.jpg    | Top view
Tek 567 plug-in bay.jpg|Plug-in bay
Tek 567 ps top.jpg                 | Top view power supply.  Blue capacitors are not original.
Tek 567 ps bottom.jpg|Bottom view power supply
Tek 567 plug-in bay.jpg             | Plug-in bay
Tek 567 plug-in connectors.jpg|Plug-in connectors rear
Tek 567 ps bottom.jpg               | Bottom view power supply
Tek 567 plug-in connectors2.jpg|Plug-in connectors front
Tek 567 plug-in connectors.jpg     | Plug-in connectors rear
S52 s4 567.jpg|567 measuring 37ps combined rise time of [[S-52]] and [[S-4]]
Tek 567 plug-in connectors2.jpg     | Plug-in connectors front
Tek-567 interconnections.png|Interconnections
S52 s4 567.jpg                     | 567 measuring 37ps combined rise time of [[S-52]] and [[S-4]]
Tek-567 power supply.png|Power Supply
Tek-567 interconnections.png       | Interconnections
Tek-567 calibrator.png|Calibrator
Tek-567 power supply.png           | Power Supply
Tek-567 crt circuit.png|CRT Circuit
Tek-567 calibrator.png             | Calibrator
Motorola mc314.png|Motorola MC314 Datasheet Specifying Tek 567 for Timing Measurements
Tek-567 crt circuit.png             | CRT Circuit
Tek rm 567 small.jpg|Rackmount Version, the RM 567
Motorola mc314.png                 | Motorola MC314 Datasheet Specifying Tek 567 for Timing Measurements
Tek rm 567 small.jpg               | Rackmount Version, the RM 567
</gallery>
</gallery>


==Components==
{{Parts|567}}


[[Category:560 series scopes]]
[[Category:560 series scopes]]
[[Category:Sampling scopes]]
[[Category:Sampling scopes]]

Latest revision as of 11:34, 15 September 2024

Manuals – Specifications – Links – Pictures

The Tektronix 567 is a sampling oscilloscope mainframe introduced in 1962.

It has a digital plug-in unit, the 6R1 or 6R1A, that can be used to measure waveform characteristics such as rise time. This digital unit provides a go/no-go output based on waveform characteristics. This feature makes the 567 particularly useful in production testing for tasks such as binning logic gates based on their speed.

The development of the 567 (and 6R1) was led by Sam McCutcheon.

The 567 came after the 661 and before the 568 and its associated 230 Digital Unit.

The 567 is a self-contained oscilloscope, but is also used as a component of S2000- and S3000-series measurement systems. In that capacity, it typically uses one of the programmable plug-ins, S-311, S-300, or S-301.

Key Specifications

  • please add

Operation

The 567 has three plug-in compartments. The left compartment holds a 3S-series sampling vertical unit such as a 3S2. The center compartment holds a 3T-series sampling sweep unit such as a 3T77. The right compartment holds the digital unit, either a 6R1 or a 6R1A. It is possible to operate a 567 without the digital unit but in that configuration it provides only the functionality that a 561 provides.

The 6R1 and 6R1A digital units have several different operating modes. These modes can be classified as time measurement or voltage measurement. One time measurement mode, for example, shows the time delay between the rising pulse edge on input A and the falling pulse edge on input B. This is useful for measuring the speed of a logic gate such as an inverter. One of the voltage measurement modes displays the difference between the input A voltage at on time and the input A voltage at some other time. This is useful for measuring the peak-to-peak amplitude of a signal.

Internals

The mechanisms used by the digital unit are a sample and hold circuit, a comparator, a counter, and a switched tap voltage divider. The digital unit takes its input from the vertical signal produced by the sampling unit. Therefore, it operates on a low-speed signal, somewhat similar to the intermediate frequency (IF) in a superheterodyne radio.

The user of the 567 positions two cursors along the X-axis. These cursors define two times and two voltages. The tapped voltage divider produces several voltages along the interval spanned by the two cursor voltages – 10%, 20%, 27%, 50%, 73%, 80%, and 90%. These voltages are used for making measurements such as the 10%-to-90% rise time. In this case, a counter is reset and started when the signal passes through the 10% voltage. The counter counts the number of cycles of a built-in crystal clock. When the signal reaches the 90% voltage, the counter is stopped and the count is displayed on the nixie tube digital numeric readout. The units and decimal place of the digital unit are controlled by switch contacts on the timing unit plug-in, which connect to the digital unit through a multi-pin connector in the 567.

The 567 does not have any post-deflection acceleration of the beam. The CRT circuit uses two 5642 high-voltage rectifier tubes, one (V822) to generate the CRT cathode voltage (−3.3 kV) and one (V832) to generate the CRT grid bias voltage. CRTs used were T5032 (earlier) and T5611 (later models).

A 567 can perform remotely controlled measurements by connecting a 262 programmer to the 6R1 or 6R1A that is in the 567.

There is an extender plug-in, the 067-0505-00, that allows a 6R1 or 6R1A to be operated outside the plug-in bay of the 567 for maintenance purposes.

Models

According to Stan Griffiths,

It looks like there were two different serial number runs of 567's.

Bench models:

  • 000101-000750 = 650 instruments
  • 002000-003280 = 1280 instruments
  • Total = 1930

Rackmount models:

  • 000101-000228 = 128 instruments
  • 002000-002240 = 240 instruments
  • Total = 368

Grand Total = approx. 2300

See Also

Pictures

Components

Some Parts Used in the 567

Part Part Number(s) Class Description Used in
0G3 154-0291-00 Gas Discharge Tube (Voltage regulator) 85 V voltage reference 132 506 547 560 561 561A 561S 564 565 567 661 TU-4 Z Keithley 610
12BH7 154-0046-00 Vacuum Tube (Dual Triode) dual triode 506 517A 561A 561S 564 567
5642 154-0051-00 154-0079-00 Vacuum Tube (Diode) directly-heated high-voltage rectifier 310 310A 316 317 360 453 502 502A 503 504 506 513 515 516 524 529 RM529 533 533A 535 536 543 543A 543B 545 545A 545B 547 551 555 556 560 561 561A 561S 564 567 570 575 581 581A 585 585A 647 647A
6080 154-0056-00 154-0315-00 Vacuum Tube (Dual Triode) dual power triode 132 160 316 317 516 535 535A RM35A 541 541A 535 536 545 545A 545B 546 547 549 565 567 575 581 581A 585 585A
6AU6 154-0022-00 157-0073-00 157-0059-00 154-0284-00 Vacuum Tube (Pentode) RF pentode 107 160 181 190 60 2A60 72 3A72 3C66 310 310A 316 317 360 502 502A 506 511 511A 512 513 516 517 517A 524 526 529 RM529 531 531A 535 536 545 545A 546 547 549 555 561 561A 561S 564 565 567 570 575 581 581A 585 585A 80 C CA Q
6BL8 154-0278-00 Vacuum Tube (Triode/Pentode) triode-pentode combo 67 2B67 3B1 3B1S 3B2 3B3 3B4 503 504 506 516 549 561 561A 561S 564 565 567 Telequipment D52 Telequipment D56 Telequipment S31 Telequipment S32 Telequipment S32A Telequipment S51 Telequipment S52
6CZ5 154-0167-00 Vacuum Tube (Pentode) power pentode 317 502 506 526 555 561 561A 561S 564 565 567
6DJ8 154-0187-00 154-0305-00 Vacuum Tube (Dual Triode) dual triode 067-506 111 132 161 310A 316 317 502 502A 503 504 506 515 516 519 526 529 RM529 533 535 536 543 544 545 545A 545B 546 547 549 555 556 561A 561S 564 565 567 581 581A 585 585A 661 1A4 1S1 60 2A60 63 2A63 67 2B67 3A1 3A1S 3A2 3A3 3A6 3A7 72 3A72 75 3A75 4S2 51 3B1 3B1S 3B2 3B3 3B4 3M1 3S76 3T77 3T77A 9A1 9A2 1121 80 81 82 86 B O W Z Telequipment D56 Telequipment S32A Telequipment D52 S-311 Telequipment TD51 Telequipment S52 Telequipment S51 Telequipment Type A TU-4
T5032 154-0319-00 154-0320-00 154-0321-00 154-0322-00 154-0355-00 154-0372-00 154-0373-00 154-0374-00 154-0375-00 154-0376-00 154-0377-00 154-0449-00 154-0454-00 154-0455-00 154-0456-00 CRT 5" rectangular-faceplate CRT 561 567
T5611 154-0531-00 154-0531-01 154-0531-02 154-0531-03 154-0613-00 154-0613-01 154-0613-02 154-0613-03 154-0614-00 154-0614-01 154-0614-02 154-0614-03 CRT ceramic CRT 561A 561B 567 568