PG502: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=PG502 | function=250 MHz pulse generator | class=pulse generator | image= | {{TM500 | mfg=Tektronix | type=PG502 | function=250 MHz pulse generator | class=pulse generator | image=PG502-front.jpg | introduced=1974 | discontinued=1993 | | ||
designers= |manuals= | designers= |manuals= | ||
* [[Media:070-1598-00.pdf|Tektronix PG502 Manual]] ( | * [[Media:070-1598-00.pdf|Tektronix PG502 Manual]] (OCR) | ||
}} | }} | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 13: | Line 13: | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_500/PG502.html PG502 page @ amplifier.cd] | * [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_500/PG502.html PG502 page @ amplifier.cd] | ||
* [http://123.physics.ucdavis.edu/electronics_files/Tek_PG502_Pulse%20Generator_Notes.pdf Description of PG502] | * [http://123.physics.ucdavis.edu/electronics_files/Tek_PG502_Pulse%20Generator_Notes.pdf Description of PG502] | ||
{{Documents|Link=PG502}} | {{Documents|Link=PG502}} | ||
{{PatentLinks|PG502}} | |||
==Rear interface== | |||
* TRIG OUT 27B,28A / GND 27A,28B (requires adding a coax cable, and for + polarity disconnecting the front-panel +TRIG OUT) | |||
* TRIG 24B / GND 25B (requires adding a coax cable and disconnecting the front-panel +TRIG/DURATION INPUT) | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek pg502 1.jpg | PG502-front.jpg | Earlier version | ||
Tek pg502 1.jpg | Later version | |||
PG502-left.jpg | PG502-left.jpg | ||
PG502-right.jpg | PG502-right.jpg |
Latest revision as of 11:10, 4 October 2024
The Tektronix PG502 is a 250 MHz pulse generator plug-in for the TM500 system.
Key Specifications
Frequency range | 10 Hz to 250 MHz |
---|---|
Pulse width | 2 ns to 5 ms, ×10 variable (i.e. up to 50 ms) |
Rise/fall time | ≤1 ns (fixed) |
Output | High and low levels adjustable independently in ±5 V range |
Features |
|
Links
Documents Referencing PG502
Patents that may apply to PG502
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 3562464A | Cam actuated switch having movable and fixed contacts on circuit board | Howard Vollum • Willem H Verhoef • Tony Sprando | 1968-10-07 | 1971-02-09 | Cam switches • 2101 • 2701 • 2703 • 432 • 434 • 465 • 475 • 5A15N • 5A18N • 5A20N • 5A21N • 5A38 • 5A45 • 5B10N • 5B12N • 7A15 • 7A16A • 7A18 • 7A19 • 7A24 • 7A26 • 7B10 • 7B15 • 7B50 • 7B51 • 7B52 • 7B53A • 7B50A • 7B70 • 7B71 • 7B80 • 7B85 • 7B87 • 7B92 • 7B92A • 7D01 • 7D12 • 7D15 • 7J20 • 7S12 • 7T11 • 7T11A • AF501 • AM502 • AM503 • DC502 • DC503 • DC504 • DC505 • DM501 • DM502 • FG501 • FG501A • FG502 • FG503 • FG504 • FG507 • PG501 • PG502 • PG505 • PG506 • PG506A • PG508 • TG501 • SC502 • SC503 • SC504 |
Rear interface
- TRIG OUT 27B,28A / GND 27A,28B (requires adding a coax cable, and for + polarity disconnecting the front-panel +TRIG OUT)
- TRIG 24B / GND 25B (requires adding a coax cable and disconnecting the front-panel +TRIG/DURATION INPUT)
Pictures
-
Earlier version
-
Later version
-
-
Components
Some Parts Used in the PG502
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
155-0064-00 | 155-0064-00 | Hybrid integrated circuit | vertical output amplifier | 7834 • 7854 • 7904 • R7903 • 7912AD • 485 • PG502 |
155-0078-00 | 155-0078-xx • 155-0273-00 • 155-0274-00 | Monolithic integrated circuit | broadband amplifier | 464 • 465 • 466 • 468 • 475 • 475A • 475M • 485 • 7834 • 7844 • 7854 • 7904 • R7903 • R7912 • 7912AD • 7912HB • 7104 • 7A16A • 7A16P • 7A24 • 7A26 • 7A42 • 067-0587-01 • 067-0680-00 • AM503 • PG502 • PG508 • DC510 • DC5010 • FG5010 |
155-0125-00 | 155-0125-00 | Hybrid integrated circuit | output amplifier | PG502 |