545: Difference between revisions
No edit summary |
No edit summary |
||
(78 intermediate revisions by 7 users not shown) | |||
Line 1: | Line 1: | ||
{{ | {{Instrument Sidebar | ||
|manufacturer=Tektronix | |||
image=Tek_545a_291_1.jpg | | |model=545 | ||
caption=Tektronix 545A front view | | |class=Oscilloscope | ||
introduced=1955 | | |series=500-series scopes | ||
discontinued=1974 | | |image=Tek_545a_291_1.jpg | ||
summary=30 (33) MHz oscilloscope | | |caption=Tektronix 545A front view | ||
manuals= | |introduced=1955 | ||
* [ | |discontinued=1974 | ||
* [ | |summary=30 (33) MHz oscilloscope | ||
* [ | |designers=John Gates;Dave Barton;Bob Shand | ||
* [ | |manuals= | ||
* [ | '''545''' | ||
* [ | * [[Media:070-198.pdf|Tektronix 545 Manual]] | ||
* [ | * [[Media:535_545_operators_handbook.pdf|Tektronix 535 and 545 Operators Handbook]] (OCR) | ||
* [ | * [[Media:tek_545_fcp.pdf|545 Factory Calibration Procedure, September 1959]] (OCR) | ||
* [ | * [[Media:Tek_545_calibration_and_maintenance_procedure.pdf|Tektronix 545 Calibration and Maintenance Procedure]] | ||
* [ | * [[Media:tek_545_calibration_maintenance_proc.pdf|Tektronix 545 Calibration and Maintenance Procedure]] (bad-OCR) | ||
* [ | * [[Media:Tek 545 mod 112.pdf|Tektronix 545 Mod 112]] | ||
'''545A''' | |||
* [[Media:070-163.pdf|545A Instruction]] (OCR) | |||
* [[Media:Using your 535A or 545A.pdf|Using your 535A or 545A (1960)]] | |||
* [[Media:Operators Handbook 535A 545A 1959.pdf|Tektronix 535A and 545A Operator's Handbook 1959]] | |||
* [[Media:tek_545a_fcp_early.pdf|545A Factory Calibration Procedure, January 1961]] (OCR) | |||
* [[Media:tek_545a_fcp.pdf|545A Factory Calibration Procedure, July 1961]] (OCR) | |||
'''545B''' | |||
* [[Media:070-428.pdf|Tektronix 545B Manual 070-428]]<br /><small>Alternate: [https://bama.edebris.com/download/tek/545b/545b.djvu DJVu @ BAMA]</small> | |||
* ''[[Media:070-438.pdf|RM543B manual 070-438 needed]]'' | |||
* [[Media:Tek 545b irb.pdf|Tektronix 545B Instrument Reference Book]] (OCR) | |||
* [[Media:Tek 545b fcp jan 1966.pdf|Tektronix 545B Factory Calibration Procedure, January 1966]] | |||
* [[Media:Tek 545b fcp tlc up to jan 1969.pdf|Tektronix 545B Factory Calibration Procedure, January 1969]] | |||
* [[Media:Tek 545b eis march 1964.pdf|Tektronix 545B Engineering Instrument Specification]] | |||
'''Maintenance and calibration''' | |||
* [https://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier] (OCR) | |||
* [https://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope] | |||
* [https://w140.com/navair_17-20aw-08.pdf Navair 17-20AW-08 Manual, which discusses the 545] | |||
}} | }} | ||
The '''Tektronix Type 545''' is a 30 (33) MHz scope that takes [[letter-series and 1-series plug-ins]]. | The '''Tektronix Type 545''' is a 30 (33) MHz scope that takes [[letter-series and 1-series plug-ins]]. It has two timebases, which allows delayed triggering. | ||
It has two timebases, which allows delayed triggering. | |||
Type 545 was [[introduced in 1955|introduced February 7th, 1955]] along with Type [[541]], and superseded in 1959 by Type 545A, | |||
which was in turn superseded in 1964 by Type 545B, which was produced until 1973. Type [[543]], which is a 541 with 100x sweep magnifier, was [[introduced in 1958]]. | |||
The difference between the 545A and 545 is the control ergonomics, not any major circuit design changes. | |||
The main improvement was to replace a pair of switches for the time base (8-position Time/Div and 6-position multiplier) | |||
with a single 24-position switch, freeing up front panel space for a Time Base B Trigger Mode rotary switch. | |||
Additionally, the delaying timebase on the 545A supports delays up to 10 seconds while the 545 supports delays only up to 100 milliseconds. | |||
The older 545 uses the [[T54|T54 / 5BHP2]] CRT, P2 [[phosphor]] was standard. | |||
The | The 545A uses the [[T5430]] CRT for which also P2 phosphor was standard. | ||
The newer 545B came with the further improved [[T5470]] CRT (also used in the [[543B]], [[544]], [[546]] and [[547]]) and P31 phosphor as standard. | |||
The | |||
== Versions == | == Versions == | ||
There were also rack-mount versions. Types RM41 and RM45 were [[introduced in 1957|introduced in October 1957]], | There were also rack-mount versions. Types RM41 and RM45 were [[introduced in 1957|introduced in October 1957]], | ||
Types RM41A and RM45A were [[introduced in 1959|introduced in May 1959]] simultaneously with their bench counterparts, and the rackmount Type RM545B or R545B was introduced at the same time as Type 545B. | Types RM41A and RM45A were [[introduced in 1959|introduced in May 1959]] simultaneously with their bench counterparts, | ||
and the rackmount Type RM545B or R545B was introduced at the same time as Type 545B. | |||
Clones of the 545A are the [[Lavoie LA-265A]] and [[Hickok 1805A]]. These clones were not licensed by Tektronix. | Clones of the 545A are the [[Lavoie LA-265A]] and [[Hickok 1805A]]. These clones were not licensed by Tektronix. | ||
=== Relationship of 545B to 547 === | === Relationship of 545B to 547 === | ||
Some feel that [[547|Type 547]] replaced Type 545, but this is not quite true; Types 545B and [[546]]/[[547]] were introduced simultaneously. | Some feel that [[547|Type 547]] replaced Type 545, but this is not quite true; Types 545B and [[546]]/[[547]] were introduced simultaneously ([[introduced in 1964|1964]]). | ||
It is more correct to say that the 50 MHz 546 and 547 were upgrades. ( | It is more correct to say that the 50 MHz 546 and 547 were upgrades. (Type 544 is likewise the upgrade for 541/543.) | ||
The Type [[K|53K/54K]] plug-in was introduced with the 545 and 541, and until Type [[L|53/54L]] came out in 1957, | The Type [[K|53K/54K]] plug-in was introduced with the 545 and 541, and until Type [[L|53/54L]] came out in 1957, | ||
Line 43: | Line 70: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 30 MHz (33 MHz with a 50 MHz plug-in such as Type [[1A1]]) }} | {{Spec | Bandwidth | 30 MHz (33 MHz with a 50 MHz plug-in such as Type [[1A1]]) }} | ||
{{SpecGroup|545B}} | |||
{{Spec | Sweep | 0.1 μs/div to 5 s/div, 1−2−5 }} | |||
{{Spec | CRT | [[T5470]]-31-2, 10 kV acceleration }} | |||
{{Spec | Probes | 2 P6006 probes with BNC connectors }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
''please add'' | ''please add'' | ||
==Links== | |||
{{Documents|Link=545}} | |||
{{Documents|Link=545A}} | |||
{{Documents|Link=545B}} | |||
==Internals== | ==Internals== | ||
Early 545 units have [[selenium rectifiers]]. Later units have silicon rectifiers. | Early 545 units have [[selenium rectifiers]]. Later units have silicon rectifiers. | ||
A modification kit, [[040-0395-00]], converts a 545 from selenium rectifiers to silicon rectifiers. | |||
The trigger circuit used a [[6DJ8]] tube in the 545 and 545A. NPN transistors are used in the 545B trigger circuit. | The trigger circuit used a [[6DJ8]] tube in the 545 and 545A. NPN transistors are used in the 545B trigger circuit. | ||
=== 545 and 545A Vertical Path === | === 545 and 545A Vertical Path === | ||
Types 545 and 545A have a six stage differential [[distributed amplifier|distributed vertical amplifier]] | Types 545 and 545A have a six stage differential [[distributed amplifier|distributed vertical amplifier]] made of twelve [[6DK6]] tubes. | ||
made of twelve [[6DK6]] tubes. | |||
The vertical amplifier used in the 545A is also used in the [[551]] and [[555]]. | The vertical amplifier used in the 545A is also used in the [[551]] and [[555]]. | ||
The 545 uses the [[154-098]] CRT. With the limited CRT technology available at the time, the higher bandwidth of the 541 and 545 came with a tradeoff. | The 545 uses the [[154-098]] CRT. With the limited CRT technology available at the time, the higher bandwidth of the 541 and 545 came with a tradeoff. | ||
The vertical scale is only 4 divisions, 2 above and 2 below the graticule center line. The lower bandwidth 531 | The vertical scale is only 4 divisions, 2 above and 2 below the graticule center line. | ||
The lower bandwidth 531/[[Type 533|533]]/535 retained the 6 vertical divisions, as used in most other Tektronix scopes. | |||
Shorting the outputs of the vertical amplifier to ground can cause | Shorting the outputs of the vertical amplifier to ground can cause expensive damage by burning out the termination resistor network. | ||
Starting at Type 545A serial number 29960, there is a 150 mA fuse, F1054, to prevent that failure. | |||
This change was made available for instruments already built, in Modification Kit 040-227. | |||
=== 545B Vertical Path === | === 545B Vertical Path === | ||
Type 545B differs significantly from the 545 and 545A. | |||
It has a partly solid-state, non-distributed vertical amp, and uses the [[154-0478-00]] CRT which is also used in the [[544]], [[546]], and [[547]]. Improvements in CRT design, including reduced deflection plate capacitance and increased sensitivity increased the vertical scale in the 545B from 4 to 6 divisions. The improved CRT also uses a ceramic envelope, with flat glass faceplate | It was designed by [[Dave Barton]]. | ||
It has a partly solid-state, non-distributed vertical amp, and uses the [[154-0478-00]] CRT which is also used in the [[544]], [[546]], and [[547]]. Improvements in CRT design, including reduced deflection plate capacitance and increased sensitivity, increased the vertical scale in the 545B from 4 to 6 divisions. The improved CRT also uses a ceramic envelope, with a flat glass faceplate with internal graticule markings to eliminate parallax errors. | |||
==Links== | ==Links== | ||
Line 77: | Line 117: | ||
<gallery> | <gallery> | ||
Tek 545 trace.jpg | Tek 545 trace.jpg | ||
Tek 545 early 1.jpg|545, early style | |||
Tek 545 early 2.jpg|545, early style | |||
Tek 545 early 3.jpg|545, early style | |||
Tek 545 early 4.jpg|545, early style | |||
Tek 545 early 5.jpg|545, early style | |||
Tek 545 early 6.jpg|545, early style | |||
Tek 545 distributed amplifier on.jpg|Distributed amplifier | |||
Tek 545 vertical rackmount.jpg|545 in vertical rackmount form | |||
Tek 545 silicon rectifier mod.JPG|545 with mod that adds silicon rectifiers in place of selenium rectifiers | |||
Tek 545 ad - Electronics - 1955-08.jpg | Tek 545 ad, ''Electronics'', August 1955 | |||
</gallery> | </gallery> | ||
===545A=== | ===545A=== | ||
<gallery> | <gallery> | ||
Tek-545A-front.jpg | |||
Tek 545a 291 1.jpg | 545A front | Tek 545a 291 1.jpg | 545A front | ||
Tek 545a 291 2.jpg | Tek 545a 291 2.jpg | ||
Line 86: | Line 137: | ||
Tek 545a 291 4.jpg | Tek 545a 291 4.jpg | ||
Tek 545a 291 5.jpg | Tek 545a 291 5.jpg | ||
Tek 545a 291 6.jpg | Tek 545a 291 6.jpg | 545A interior, right side | ||
Tek 545a 291 7.jpg | Tek 545a 291 7.jpg | 545A interior, left side | ||
Tek-545a-right1.jpg | 545A interior, right side detail (time base B chassis open) | |||
Tek-545a-timebase-a.jpg | 545A interior, right side detail (time base A) | |||
Tek-545a-timebase-b.jpg | 545A interior, right side detail (time base B) | |||
Tek-545a-hv-1.jpg | 545A interior, HV supply | |||
Tek-545a-hv-2.jpg | 545A interior, HV supply | |||
Tek-545a-hv-osc.jpg | 545A interior, HV oscillator tube | |||
Tek-545a-rectifier.jpg | 545A interior, rectifier | |||
Tek-545a-bottom1.jpg | 545A interior, bottom view | |||
Tek-545a-bottom2.jpg | 545A interior, bottom view (DC voltage regulator section detail) | |||
Tek-545a-bottom3.jpg | 545A interior, bottom view (distributed amplifier section detail) | |||
Tek 545a delay line.jpg | 545A Delay line | Tek 545a delay line.jpg | 545A Delay line | ||
Tek_545a_blockdiagram.png | 545A block diagram | Tek_545a_blockdiagram.png | 545A block diagram | ||
545a_vert.png | 545A signal path | 545a_vert.png | 545A signal path | ||
Tek 545a close trace.jpg| 545A trace | |||
Tek 545a handbook compartment1.jpg|545A handbook compartment | |||
Tek 545a handbook compartment2.jpg|545A handbook compartment | |||
Tek 545a on 202-1.jpg|545A on a Tek 202-1 cart | |||
Tek 545a controls.jpg|545A controls | |||
Tek 545a trace.jpg|545A trace | |||
Tek 545a trace2.jpg|545A trace | |||
</gallery> | </gallery> | ||
Line 108: | Line 176: | ||
Tek rm45a 10.jpg | Tek rm45a 10.jpg | ||
Tek rm45a 404.jpg|RM 45A with standard B timebase | Tek rm45a 404.jpg|RM 45A with standard B timebase | ||
Tek rm45a on pallet.jpg|RM 45A with | Tek rm45a on pallet.jpg|RM 45A with raster B timebase, MOD 116B | ||
tek_rm45a_goddard.jpg|RM45A from NASA | |||
</gallery> | </gallery> | ||
Line 114: | Line 183: | ||
<gallery> | <gallery> | ||
Tek 545b front.jpg | 545B front | Tek 545b front.jpg | 545B front | ||
545B guernsey.JPG | a british made 545B (Tektronix Guernsey LTD. ) | |||
Tek 545b trace.jpg | 545B with [[M|Type M plug-in]] | Tek 545b trace.jpg | 545B with [[M|Type M plug-in]] | ||
Tek 545b right.jpg | 545B right side | |||
Tek 545b trace2.jpg | 545B with 1A1 | |||
545b_vertical.png | 545B signal path | 545b_vertical.png | 545B signal path | ||
Tek 545b top.jpg | 545B top | Tek 545b top.jpg | 545B top | ||
Tek 545b rear.jpg | 545B rear | |||
Tek 545b right internal.jpg | 545B right internal | Tek 545b right internal.jpg | 545B right internal | ||
Tek 545b vert output.jpg | 545B vertical output stage | Tek 545b vert output.jpg | 545B vertical output stage | ||
Line 144: | Line 217: | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|545}} | |||
{{Parts|RM45}} | |||
{{Parts|545A}} | |||
{{Parts|545B}} | |||
{{Parts|RM545B}} | |||
[[Category:500 series scopes]] | [[Category:500 series scopes]] | ||
[[Category:Introduced in 1955]] | [[Category:Introduced in 1955]] |
Revision as of 05:27, 11 March 2024
The Tektronix Type 545 is a 30 (33) MHz scope that takes letter-series and 1-series plug-ins. It has two timebases, which allows delayed triggering.
Type 545 was introduced February 7th, 1955 along with Type 541, and superseded in 1959 by Type 545A, which was in turn superseded in 1964 by Type 545B, which was produced until 1973. Type 543, which is a 541 with 100x sweep magnifier, was introduced in 1958.
The difference between the 545A and 545 is the control ergonomics, not any major circuit design changes. The main improvement was to replace a pair of switches for the time base (8-position Time/Div and 6-position multiplier) with a single 24-position switch, freeing up front panel space for a Time Base B Trigger Mode rotary switch. Additionally, the delaying timebase on the 545A supports delays up to 10 seconds while the 545 supports delays only up to 100 milliseconds.
The older 545 uses the T54 / 5BHP2 CRT, P2 phosphor was standard. The 545A uses the T5430 CRT for which also P2 phosphor was standard. The newer 545B came with the further improved T5470 CRT (also used in the 543B, 544, 546 and 547) and P31 phosphor as standard.
Versions
There were also rack-mount versions. Types RM41 and RM45 were introduced in October 1957, Types RM41A and RM45A were introduced in May 1959 simultaneously with their bench counterparts, and the rackmount Type RM545B or R545B was introduced at the same time as Type 545B.
Clones of the 545A are the Lavoie LA-265A and Hickok 1805A. These clones were not licensed by Tektronix.
Relationship of 545B to 547
Some feel that Type 547 replaced Type 545, but this is not quite true; Types 545B and 546/547 were introduced simultaneously (1964). It is more correct to say that the 50 MHz 546 and 547 were upgrades. (Type 544 is likewise the upgrade for 541/543.)
The Type 53K/54K plug-in was introduced with the 545 and 541, and until Type 53/54L came out in 1957, it was the only plug-in that could take full advantage of their bandwidth. There was never a full-speed dual-trace plug-in — that would wait until Types 1A1 and 1A2, which came out with the 545B.
Key Specifications
Bandwidth | 30 MHz (33 MHz with a 50 MHz plug-in such as Type 1A1) |
---|---|
— 545B — | |
Sweep | 0.1 μs/div to 5 s/div, 1−2−5 |
CRT | T5470-31-2, 10 kV acceleration |
Probes | 2 P6006 probes with BNC connectors |
please add
Links
Documents Referencing 545
- (no results)
Documents Referencing 545A
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
IBM 223-6725-2.pdf | Application Note | Tektronix oscilloscopes (IBM Customer Engineering Manual) | 1960 | 310 • 310A • 531 • 531A • 535 • 535A • 545A • B • C • CA • D • G |
Documents Referencing 545B
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Service Scope 44 Jun 1967.pdf | Article | A Practical Approach to Transistor and Vacuum Tube Amplifiers, Part 3 - A DC Analysis of a Typical Tektronix Hybrid Circuit | Fred Beckett | 1967 | 545B |
Internals
Early 545 units have selenium rectifiers. Later units have silicon rectifiers. A modification kit, 040-0395-00, converts a 545 from selenium rectifiers to silicon rectifiers.
The trigger circuit used a 6DJ8 tube in the 545 and 545A. NPN transistors are used in the 545B trigger circuit.
545 and 545A Vertical Path
Types 545 and 545A have a six stage differential distributed vertical amplifier made of twelve 6DK6 tubes. The vertical amplifier used in the 545A is also used in the 551 and 555. The 545 uses the 154-098 CRT. With the limited CRT technology available at the time, the higher bandwidth of the 541 and 545 came with a tradeoff. The vertical scale is only 4 divisions, 2 above and 2 below the graticule center line. The lower bandwidth 531/533/535 retained the 6 vertical divisions, as used in most other Tektronix scopes. Shorting the outputs of the vertical amplifier to ground can cause expensive damage by burning out the termination resistor network. Starting at Type 545A serial number 29960, there is a 150 mA fuse, F1054, to prevent that failure. This change was made available for instruments already built, in Modification Kit 040-227.
545B Vertical Path
Type 545B differs significantly from the 545 and 545A. It was designed by Dave Barton. It has a partly solid-state, non-distributed vertical amp, and uses the 154-0478-00 CRT which is also used in the 544, 546, and 547. Improvements in CRT design, including reduced deflection plate capacitance and increased sensitivity, increased the vertical scale in the 545B from 4 to 6 divisions. The improved CRT also uses a ceramic envelope, with a flat glass faceplate with internal graticule markings to eliminate parallax errors.
Links
- J.Evans' 545A page / 545B page
- radiomuseum.org: 545 / 545A / 545B
- Richard Sears: Tektronix 535A and 545A
- barrytech.com: 545 / 545A / 545B
Pictures
545
-
-
545, early style
-
545, early style
-
545, early style
-
545, early style
-
545, early style
-
545, early style
-
Distributed amplifier
-
545 in vertical rackmount form
-
545 with mod that adds silicon rectifiers in place of selenium rectifiers
-
Tek 545 ad, Electronics, August 1955
545A
-
-
545A front
-
-
-
-
-
545A interior, right side
-
545A interior, left side
-
545A interior, right side detail (time base B chassis open)
-
545A interior, right side detail (time base A)
-
545A interior, right side detail (time base B)
-
545A interior, HV supply
-
545A interior, HV supply
-
545A interior, HV oscillator tube
-
545A interior, rectifier
-
545A interior, bottom view
-
545A interior, bottom view (DC voltage regulator section detail)
-
545A interior, bottom view (distributed amplifier section detail)
-
545A Delay line
-
545A block diagram
-
545A signal path
-
545A trace
-
545A handbook compartment
-
545A handbook compartment
-
545A on a Tek 202-1 cart
-
545A controls
-
545A trace
-
545A trace
RM45A
-
RM45A, standard color
-
RM45A rear
-
Brown-face RM45A
-
-
-
-
-
-
-
-
-
-
RM 45A with standard B timebase
-
RM 45A with raster B timebase, MOD 116B
-
RM45A from NASA
545B
-
545B front
-
a british made 545B (Tektronix Guernsey LTD. )
-
545B with Type M plug-in
-
545B right side
-
545B with 1A1
-
545B signal path
-
545B top
-
545B rear
-
545B right internal
-
545B vertical output stage
-
545B vertical output stage
-
545B Block Diagram
-
545B Power Supply
-
545B High Voltage Power Supply
-
545B Calibrator
-
545B Trigger A
-
545B Timebase A
-
545B Trigger B
-
545B Timebase B
-
545B Horizontal Amp
-
545B with 1S2
-
545B left internal
-
545B right internal
-
545B left external
-
545B right external
-
545B top external
-
545B Squarewave
RM545B
-
RM545B
Components
Some Parts Used in the 545
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
12AL5 | 154-0038-00 | Vacuum Tube (Double Diode) | high-perveance dual diode | 3A2 • 3B2 • 545 • 545A • 549 • N |
12AU6 | 154-0040-00 | Vacuum Tube (Pentode) | RF pentode | 81 • 112 • 1L10 • 1L20 • 1L60 • 3L10 • 512 • 556 • 575 • 545 • 547 • 549 • 581 • 585 • A • B • C • G • K • H • L • ML • M • N • O • R • S • Z |
12AU7 | 154-041 • 154-0041-00 • 154-0287-00 | Vacuum Tube (Dual Triode) | dual medium-μ triode | 104 • 104A • 122 • 160 • 161 • 162 • 181 • 190 • 310 • 310A • 316 • 317 • 3C66 • 502 • 502A • 507 • 511A • 512 • 516 • 517 • 517A • 524 • 526 • 535 • 536 • 545 • 545A • 545B • 547 • 549 • 555 • 561 • 564 • 570 • 575 • 581 • 581A • 585 • 585A • C • D • E • N • Q • Hickok 1825 |
12AX7 | 154-043 • 154-0043-00 | Vacuum Tube (Dual Triode) | dual triode | 3C66 • 513 • 524 • 531 • 531A • 535 • 536 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 570 • 581 • 581A • 585 • 585A • E • Q • Hickok 1825 • Keithley 610 |
12B4 | 154-044 • 154-0044-00 | Vacuum Tube (Triode) | power triode | 126 • 310 • 310A • 316 • 317 • 502 • 502A • 524 • 526 • 541 • 541A • 535 • 535A • 545 • 545A • 546 • 547 • 570 • 549 • 551 • 555 • 513 • 581 • 581A • 585 • 585A • Keithley 610 |
12BY7A | 154-047 • 154-0047-00 | Vacuum Tube (Pentode) | miniature 6.5 W power pentode | 106 • 163 • 524 • 531 • 533 • 535 • 536 • 541 • 543 • 535 • 545 • 545A • 549 • 555 • 75 • 3A75 • 3B5 |
5642 | 154-0051-00 • 154-0079-00 | Vacuum Tube (Diode) | directly-heated high-voltage rectifier | 310 • 310A • 316 • 317 • 360 • 453 • 502 • 502A • 503 • 504 • 506 • 513 • 515 • 516 • 524 • 529 • RM529 • 533 • 533A • 535 • 536 • 543 • 543A • 543B • 545 • 545A • 545B • 547 • 551 • 555 • 556 • 560 • 561 • 561A • 561S • 564 • 567 • 570 • 575 • 581 • 581A • 585 • 585A • 647 • 647A |
5651 | 154-052 • 154-0052-00 • 154-0288-00 | Gas Discharge Tube (Voltage regulator) | 87 V voltage reference | 128 • 160 • 310 • 310A • 502 • 503 • 504 • 511A • 512 • 516 • 517 • 524 • 526 • 531 • 531A • 535 • 536 • 541 • 541A • 543 • 543A • 543B • 545 • 545A • 545B • 570 • 549 • 581 • 581A • 585 • 585A |
5BHP | 154-0142-00 • 154-152 • 154-0409-00 • 154-409 • 154-0106-00 • 154-106 • 154-0098-00 • 154-098 • 154-0099-00 • 154-099 • 154-0104-00 • 154-104 | CRT | 5" CRT | 541 • 545 |
6080 | 154-0056-00 • 154-0315-00 | Vacuum Tube (Dual Triode) | dual power triode | 132 • 160 • 316 • 317 • 516 • 535 • 535A • RM35A • 541 • 541A • 535 • 536 • 545 • 545A • 545B • 546 • 547 • 549 • 565 • 567 • 575 • 581 • 581A • 585 • 585A |
6AL5 | 154-016 • 154-0016-00 • 154-0038-00 | Vacuum Tube (Dual Diode) | high-perveance dual diode | 163 • 181 • 190 • 1M1 • 310 • 310A • 315 • 316 • 317 • 3B1 • 3B1S • 3B2 • 3B3 • 3B5 • 502 • 502A • 503 • 511 • 511A • 512 • 516 • 517 • 517A • 524 • 526 • 535 • 535A • 545 • 545A • 549 • 551 • 565 • 570 • 581 • 581A • 585 • 585A • C • T • Telequipment D52 • Telequipment D56 • Telequipment S52 |
6AU5 | 154-021 • 154-0021-00 | Vacuum Tube (Pentode) | 10 W beam power pentode | 507 • 513 • 516 • 517 • 517A • 531 • 535 • 541 • 535 • 545 • 547 • 581 • 581A • 585 • 585A |
6AU6 | 154-0022-00 • 157-0073-00 • 157-0059-00 • 154-0284-00 | Vacuum Tube (Pentode) | RF pentode | 107 • 160 • 181 • 190 • 60 • 2A60 • 72 • 3A72 • 3C66 • 310 • 310A • 316 • 317 • 360 • 502 • 502A • 506 • 511 • 511A • 512 • 513 • 516 • 517 • 517A • 524 • 526 • 529 • RM529 • 531 • 531A • 535 • 536 • 545 • 545A • 546 • 547 • 549 • 555 • 561 • 561A • 561S • 564 • 565 • 567 • 570 • 575 • 581 • 581A • 585 • 585A • 80 • C • CA • Q |
6AW8 | 154-0095-00 | Vacuum Tube (Triode/Pentode) | triode-pentode combo | 132 • 160 • 541 • 535 • 545 |
6BQ7A | 154-028 • 154-0028-00 • 157-0022-00 • 157-0003-00 | Vacuum Tube (Dual Triode) | dual triode | 107 • 163 • 181 • 310 • 315 • 316 • 360 • 524 • 531 • 532 • 535 • 536 • 541 • 545 • 570 • T |
6CB6A | 154-0030-00 | Vacuum Tube (Pentode) | pentode | 105 • 112 • 316 • 317 • 503 • 504 • 513 • 517 • 517A • 541 • 535 • 545 • 63 • 2A63 |
6CL6 | 154-031 • 154-0031-00 • 154-0286-00 | Vacuum Tube (Pentode) | 7.5 W power pentode | 132 • 310 • 310A • 316 • 317 • 515 • 524 • 525 • 531 • 535 • 535A • 545 • 545A • 545B • 549 • 570 • 581 • 581A • 585 • 585A • 3A74 |
6DJ8 | 154-0187-00 • 154-0305-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 111 • 132 • 161 • 310A • 316 • 317 • 502 • 502A • 503 • 504 • 506 • 515 • 516 • 519 • 526 • 529 • RM529 • 533 • 535 • 536 • 543 • 544 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 556 • 561A • 561S • 564 • 565 • 567 • 581 • 581A • 585 • 585A • 661 • 1A4 • 1S1 • 60 • 2A60 • 63 • 2A63 • 67 • 2B67 • 3A1 • 3A1S • 3A2 • 3A3 • 3A6 • 3A7 • 72 • 3A72 • 75 • 3A75 • 4S2 • 51 • 3B1 • 3B1S • 3B2 • 3B3 • 3B4 • 3M1 • 3S76 • 3T77 • 3T77A • 9A1 • 9A2 • 1121 • 80 • 81 • 82 • 86 • B • O • W • Z • Telequipment D56 • Telequipment S32A • Telequipment D52 • S-311 • Telequipment TD51 • Telequipment S52 • Telequipment S51 • Telequipment Type A • TU-4 |
6DK6 | 154-0149-00 • 154-0367-00 | Vacuum Tube (Pentode) | high-frequency miniature pentode | 180 • 503 • 513 • 514 • 541 • 543 • 535 • 545 • 545A • 551 • 555 |
6U8 | 154-0033-00 | Vacuum Tube (Triode/Pentode) | triode-pentode combo | 130 • 160 • 163 • 310 • 315 • 316 • 524 • 535 • 545 • T |
T54 | 154-0098-00 • 154-0099-00 • 154-0104-00 • 154-0105-00 • 154-0106-00 • 154-0142-00 | CRT | CRT | 541 • 545 |
Some Parts Used in the RM45
- (no results)
Some Parts Used in the 545A
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
12AL5 | 154-0038-00 | Vacuum Tube (Double Diode) | high-perveance dual diode | 3A2 • 3B2 • 545 • 545A • 549 • N |
12AU7 | 154-041 • 154-0041-00 • 154-0287-00 | Vacuum Tube (Dual Triode) | dual medium-μ triode | 104 • 104A • 122 • 160 • 161 • 162 • 181 • 190 • 310 • 310A • 316 • 317 • 3C66 • 502 • 502A • 507 • 511A • 512 • 516 • 517 • 517A • 524 • 526 • 535 • 536 • 545 • 545A • 545B • 547 • 549 • 555 • 561 • 564 • 570 • 575 • 581 • 581A • 585 • 585A • C • D • E • N • Q • Hickok 1825 |
12AX7 | 154-043 • 154-0043-00 | Vacuum Tube (Dual Triode) | dual triode | 3C66 • 513 • 524 • 531 • 531A • 535 • 536 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 570 • 581 • 581A • 585 • 585A • E • Q • Hickok 1825 • Keithley 610 |
12B4 | 154-044 • 154-0044-00 | Vacuum Tube (Triode) | power triode | 126 • 310 • 310A • 316 • 317 • 502 • 502A • 524 • 526 • 541 • 541A • 535 • 535A • 545 • 545A • 546 • 547 • 570 • 549 • 551 • 555 • 513 • 581 • 581A • 585 • 585A • Keithley 610 |
12BY7A | 154-047 • 154-0047-00 | Vacuum Tube (Pentode) | miniature 6.5 W power pentode | 106 • 163 • 524 • 531 • 533 • 535 • 536 • 541 • 543 • 535 • 545 • 545A • 549 • 555 • 75 • 3A75 • 3B5 |
5642 | 154-0051-00 • 154-0079-00 | Vacuum Tube (Diode) | directly-heated high-voltage rectifier | 310 • 310A • 316 • 317 • 360 • 453 • 502 • 502A • 503 • 504 • 506 • 513 • 515 • 516 • 524 • 529 • RM529 • 533 • 533A • 535 • 536 • 543 • 543A • 543B • 545 • 545A • 545B • 547 • 551 • 555 • 556 • 560 • 561 • 561A • 561S • 564 • 567 • 570 • 575 • 581 • 581A • 585 • 585A • 647 • 647A |
5651 | 154-052 • 154-0052-00 • 154-0288-00 | Gas Discharge Tube (Voltage regulator) | 87 V voltage reference | 128 • 160 • 310 • 310A • 502 • 503 • 504 • 511A • 512 • 516 • 517 • 524 • 526 • 531 • 531A • 535 • 536 • 541 • 541A • 543 • 543A • 543B • 545 • 545A • 545B • 570 • 549 • 581 • 581A • 585 • 585A |
6080 | 154-0056-00 • 154-0315-00 | Vacuum Tube (Dual Triode) | dual power triode | 132 • 160 • 316 • 317 • 516 • 535 • 535A • RM35A • 541 • 541A • 535 • 536 • 545 • 545A • 545B • 546 • 547 • 549 • 565 • 567 • 575 • 581 • 581A • 585 • 585A |
6AL5 | 154-016 • 154-0016-00 • 154-0038-00 | Vacuum Tube (Dual Diode) | high-perveance dual diode | 163 • 181 • 190 • 1M1 • 310 • 310A • 315 • 316 • 317 • 3B1 • 3B1S • 3B2 • 3B3 • 3B5 • 502 • 502A • 503 • 511 • 511A • 512 • 516 • 517 • 517A • 524 • 526 • 535 • 535A • 545 • 545A • 549 • 551 • 565 • 570 • 581 • 581A • 585 • 585A • C • T • Telequipment D52 • Telequipment D56 • Telequipment S52 |
6AU6 | 154-0022-00 • 157-0073-00 • 157-0059-00 • 154-0284-00 | Vacuum Tube (Pentode) | RF pentode | 107 • 160 • 181 • 190 • 60 • 2A60 • 72 • 3A72 • 3C66 • 310 • 310A • 316 • 317 • 360 • 502 • 502A • 506 • 511 • 511A • 512 • 513 • 516 • 517 • 517A • 524 • 526 • 529 • RM529 • 531 • 531A • 535 • 536 • 545 • 545A • 546 • 547 • 549 • 555 • 561 • 561A • 561S • 564 • 565 • 567 • 570 • 575 • 581 • 581A • 585 • 585A • 80 • C • CA • Q |
6CL6 | 154-031 • 154-0031-00 • 154-0286-00 | Vacuum Tube (Pentode) | 7.5 W power pentode | 132 • 310 • 310A • 316 • 317 • 515 • 524 • 525 • 531 • 535 • 535A • 545 • 545A • 545B • 549 • 570 • 581 • 581A • 585 • 585A • 3A74 |
6DJ8 | 154-0187-00 • 154-0305-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 111 • 132 • 161 • 310A • 316 • 317 • 502 • 502A • 503 • 504 • 506 • 515 • 516 • 519 • 526 • 529 • RM529 • 533 • 535 • 536 • 543 • 544 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 556 • 561A • 561S • 564 • 565 • 567 • 581 • 581A • 585 • 585A • 661 • 1A4 • 1S1 • 60 • 2A60 • 63 • 2A63 • 67 • 2B67 • 3A1 • 3A1S • 3A2 • 3A3 • 3A6 • 3A7 • 72 • 3A72 • 75 • 3A75 • 4S2 • 51 • 3B1 • 3B1S • 3B2 • 3B3 • 3B4 • 3M1 • 3S76 • 3T77 • 3T77A • 9A1 • 9A2 • 1121 • 80 • 81 • 82 • 86 • B • O • W • Z • Telequipment D56 • Telequipment S32A • Telequipment D52 • S-311 • Telequipment TD51 • Telequipment S52 • Telequipment S51 • Telequipment Type A • TU-4 |
6DK6 | 154-0149-00 • 154-0367-00 | Vacuum Tube (Pentode) | high-frequency miniature pentode | 180 • 503 • 513 • 514 • 541 • 543 • 535 • 545 • 545A • 551 • 555 |
8426 | Vacuum Tube (Pentode) | RF pentode | O • 545A • 547 • 549 • 581A • 585A | |
NE-2 | 150-002 • 150-0002-00 | Gas Discharge Tube (neon lamp) | Neon lamp | 511 • 511A • 581 • 581A • 585 • 585A • 545A • TU-4 |
T5430 | 154-0175-00 • 154-0758-00 • 154-0758-03 • 154-0758-04 • 154-0183-00 | CRT | 5" CRT | 541A • 543 • 543A • 545A |
Some Parts Used in the 545B
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
120-0308-00 | 120-0308-00 | Discrete component | high voltage transformer | 543B • 544 • 545B • 546 • 547 |
120-0344-00 | 120-0344-00 | Discrete component | power transformer | 545B |
12AU7 | 154-041 • 154-0041-00 • 154-0287-00 | Vacuum Tube (Dual Triode) | dual medium-μ triode | 104 • 104A • 122 • 160 • 161 • 162 • 181 • 190 • 310 • 310A • 316 • 317 • 3C66 • 502 • 502A • 507 • 511A • 512 • 516 • 517 • 517A • 524 • 526 • 535 • 536 • 545 • 545A • 545B • 547 • 549 • 555 • 561 • 564 • 570 • 575 • 581 • 581A • 585 • 585A • C • D • E • N • Q • Hickok 1825 |
12AX7 | 154-043 • 154-0043-00 | Vacuum Tube (Dual Triode) | dual triode | 3C66 • 513 • 524 • 531 • 531A • 535 • 536 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 570 • 581 • 581A • 585 • 585A • E • Q • Hickok 1825 • Keithley 610 |
5642 | 154-0051-00 • 154-0079-00 | Vacuum Tube (Diode) | directly-heated high-voltage rectifier | 310 • 310A • 316 • 317 • 360 • 453 • 502 • 502A • 503 • 504 • 506 • 513 • 515 • 516 • 524 • 529 • RM529 • 533 • 533A • 535 • 536 • 543 • 543A • 543B • 545 • 545A • 545B • 547 • 551 • 555 • 556 • 560 • 561 • 561A • 561S • 564 • 567 • 570 • 575 • 581 • 581A • 585 • 585A • 647 • 647A |
5651 | 154-052 • 154-0052-00 • 154-0288-00 | Gas Discharge Tube (Voltage regulator) | 87 V voltage reference | 128 • 160 • 310 • 310A • 502 • 503 • 504 • 511A • 512 • 516 • 517 • 524 • 526 • 531 • 531A • 535 • 536 • 541 • 541A • 543 • 543A • 543B • 545 • 545A • 545B • 570 • 549 • 581 • 581A • 585 • 585A |
6080 | 154-0056-00 • 154-0315-00 | Vacuum Tube (Dual Triode) | dual power triode | 132 • 160 • 316 • 317 • 516 • 535 • 535A • RM35A • 541 • 541A • 535 • 536 • 545 • 545A • 545B • 546 • 547 • 549 • 565 • 567 • 575 • 581 • 581A • 585 • 585A |
6CL6 | 154-031 • 154-0031-00 • 154-0286-00 | Vacuum Tube (Pentode) | 7.5 W power pentode | 132 • 310 • 310A • 316 • 317 • 515 • 524 • 525 • 531 • 535 • 535A • 545 • 545A • 545B • 549 • 570 • 581 • 581A • 585 • 585A • 3A74 |
6DJ8 | 154-0187-00 • 154-0305-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 111 • 132 • 161 • 310A • 316 • 317 • 502 • 502A • 503 • 504 • 506 • 515 • 516 • 519 • 526 • 529 • RM529 • 533 • 535 • 536 • 543 • 544 • 545 • 545A • 545B • 546 • 547 • 549 • 555 • 556 • 561A • 561S • 564 • 565 • 567 • 581 • 581A • 585 • 585A • 661 • 1A4 • 1S1 • 60 • 2A60 • 63 • 2A63 • 67 • 2B67 • 3A1 • 3A1S • 3A2 • 3A3 • 3A6 • 3A7 • 72 • 3A72 • 75 • 3A75 • 4S2 • 51 • 3B1 • 3B1S • 3B2 • 3B3 • 3B4 • 3M1 • 3S76 • 3T77 • 3T77A • 9A1 • 9A2 • 1121 • 80 • 81 • 82 • 86 • B • O • W • Z • Telequipment D56 • Telequipment S32A • Telequipment D52 • S-311 • Telequipment TD51 • Telequipment S52 • Telequipment S51 • Telequipment Type A • TU-4 |
7119 | 154-0340-00 | Vacuum Tube (Dual Triode) | dual triode | 067-506 • 067-0532-00 • 191 • 3A3 • 3B4 • 3B5 • 516 • 545B • 549 • 661 • Chemtrix 205 |
7788 | 154-0420-00 | Vacuum Tube (Pentode) | long life, shock and vibration resistant pentode | 529 • RM529 • 581A • 585A • RM581 • RM585 • Telequipment D56 • 545B |
T5470 | 154-0429-00 • 154-0450-00 • 154-0451-00 • 154-0452-00 • 154-0457-00 • 154-0458-00 • 154-0459-00 • 154-0478-00 • 154-0478-01 • 154-0478-02 • 154-0478-03 • 154-0568-00 • 154-0568-01 • 154-0568-02 • 154-0568-03 | CRT | 5" electrostatic deflection CRT | 543B • 544 • 545B • 546 • 547 |
Some Parts Used in the RM545B
- (no results)