FG501: Difference between revisions
Jump to navigation
Jump to search
(→FG501) |
No edit summary |
||
(17 intermediate revisions by 6 users not shown) | |||
Line 1: | Line 1: | ||
{{TM500 | mfg=Tektronix | type=FG501 | function=function generator | class=function generator | image= | {{TM500 | mfg=Tektronix | type=FG501 | function=function generator | class=function generator | image=FG501 front.jpg | introduced=1972 | discontinued=1981 | ||
designers= |manuals= | |designers=Roger Stenbock | ||
* [[Media:070-1431-01.pdf|Tektronix FG501 Manual]] | |manuals= | ||
* [[Media:070-1431-01.pdf|Tektronix FG501 Manual]] (OCR) | |||
}} | }} | ||
The FG501 was designed by [[Roger Stenbock]]. It was replaced by the [[FG501A]] in 1981. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Frequency | 0.01 Hz to 1 MHz in decade steps}} | |||
{{Spec | Frequency | 0.01 Hz to 1 MHz in decade steps }} | {{Spec | Output | Max. 20 V<sub>p-p</sub> into high impedance, 10 V into 50 Ω (SN < B130000: 15/7.5 V)}} | ||
{{Spec | Output | Max. 20 V<sub>p-p</sub> into high impedance, 10 V into 50 Ω (SN < B130000: 15/7.5 V)}} | {{Spec | Offset | Max. ±7.5 V<sub>p-p</sub> into high impedance, 5 V into 50 Ω (SN < B130000: 5/2.5 V) }} | ||
{{Spec | Offset | Max. ±7.5 V<sub>p-p</sub> into high impedance, 5 V into 50 Ω (SN < B130000: 5/2.5 V | {{Spec | Signals | sine, square, triangle, ramp, pulse }} | ||
{{Spec | Features | | |||
{{Spec | Signals | sine, square, triangle, ramp, pulse }} | |||
{{Spec | Features | | |||
* voltage controlled frequency input (1000:1 ratio) | * voltage controlled frequency input (1000:1 ratio) | ||
* triggering | * triggering | ||
* variable phase control | * gated output with variable phase control | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
The TRIG OUT signal is available on the front panel via a [[BSM|BSM female connector]]. | |||
The Phase control is effective in gated mode to control the starting phase of the generated waveform. | |||
==Links== | ==Links== | ||
* | {{Documents|Link=FG501}} | ||
* | {{PatentLinks|FG501}} | ||
==Rear Interface== | |||
* Output: 28A (Common 27A) | |||
* Trigger Output: 27B (Common 28B) | |||
* Gate Input: 24B (Common 25B) | |||
* VCF Input: 21B (Common 22B) | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
FG501 front.jpg | |||
Tek fg501.JPG | Tek fg501.JPG | ||
FG-501-IMG_2733.JPG | FG-501-IMG_2733.JPG | ||
FG-501-IMG_2735.JPG | FG-501-IMG_2735.JPG | ||
FG-501-IMG_2736.JPG | |||
FG-501-IMG_2738.JPG | FG-501-IMG_2738.JPG | ||
</gallery> | </gallery> | ||
=== | ==Components== | ||
{{Parts|FG501}} | |||
Latest revision as of 22:28, 14 October 2024
The Tektronix FG501 is a function generator plug-in for the TM500 system.
The FG501 was designed by Roger Stenbock. It was replaced by the FG501A in 1981.
Key Specifications
Frequency | 0.01 Hz to 1 MHz in decade steps |
---|---|
Output | Max. 20 Vp-p into high impedance, 10 V into 50 Ω (SN < B130000: 15/7.5 V) |
Offset | Max. ±7.5 Vp-p into high impedance, 5 V into 50 Ω (SN < B130000: 5/2.5 V) |
Signals | sine, square, triangle, ramp, pulse |
Features |
|
The TRIG OUT signal is available on the front panel via a BSM female connector.
The Phase control is effective in gated mode to control the starting phase of the generated waveform.
Links
Documents Referencing FG501
Patents that may apply to FG501
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 3562464A | Cam actuated switch having movable and fixed contacts on circuit board | Howard Vollum • Willem H Verhoef • Tony Sprando | 1968-10-07 | 1971-02-09 | Cam switches • 2101 • 2701 • 2703 • 432 • 434 • 465 • 475 • 5A15N • 5A18N • 5A20N • 5A21N • 5A38 • 5A45 • 5B10N • 5B12N • 7A15 • 7A16A • 7A18 • 7A19 • 7A24 • 7A26 • 7B10 • 7B15 • 7B50 • 7B51 • 7B52 • 7B53A • 7B50A • 7B70 • 7B71 • 7B80 • 7B85 • 7B87 • 7B92 • 7B92A • 7D01 • 7D12 • 7D15 • 7J20 • 7S12 • 7T11 • 7T11A • AF501 • AM502 • AM503 • DC502 • DC503 • DC504 • DC505 • DM501 • DM502 • FG501 • FG501A • FG502 • FG503 • FG504 • FG507 • PG501 • PG502 • PG505 • PG506 • PG506A • PG508 • TG501 • SC502 • SC503 • SC504 |
Rear Interface
- Output: 28A (Common 27A)
- Trigger Output: 27B (Common 28B)
- Gate Input: 24B (Common 25B)
- VCF Input: 21B (Common 22B)
Pictures
Components
Some Parts Used in the FG501
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
151-0261-00 | 151-0261-00 | Discrete component | dual PNP transistor | AM501 • AM502 • CG5001 • CG551AP • FG501 • FG502 • FG503 • OF150 • OF151 • OF152 • OF235 • OS261 • RM502A • R1140 • R5030 • R5031 • R7912 • 067-0679-00 • 067-0807-00 • 1101 • 1140A • 1141 • 1142 • 1350 • 145 • 1450 • 1480 • 1481 • 1482 • 1485 • 1501 • 1801 • 1900 • 1910 • 1980 • 213 • 26A1 • 26A2 • 2620 • 285 • 3A9 • 3A10 • 3S1 • 3S2 • 3S5 • 3S6 • 432 • 434 • 4501 • 454 • 4601 • 4602 • 4610 • 4612 • 4620 • 4632 • 4634 • 4701 • 475 • 492 • 492A • 492AP • 494 • 494P • 496 • 496P • 5A13N • 5A20N • 5A21N • 5A22N • 5A26 • 5L4N • 502A • 5030 • 5031 • 576 • 690SR • 7A22 • 7A29 • 7B51 • 7B71 • 7J20 • 7L5 • 7S11 • 7S12 • 7912AD |