465: Difference between revisions
No edit summary |
No edit summary |
||
(85 intermediate revisions by 11 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar | | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
summary=Portable 100 MHz dual-trace scope | | |series=400-series scopes | ||
image=Tek 465 trace.jpg| | |model=465 | ||
caption=Tektronix 465 | |summary=Portable 100 MHz dual-trace scope | ||
introduced=1972 | | |image=Tek 465 trace.jpg | ||
discontinued=1983 | | |caption=Tektronix 465 Front | ||
manuals= | |introduced=1972 | ||
* [ | |discontinued=1983 | ||
* [ | |designers=Leon Orchard;Luis Navarro;Bob Shand;Jim Hinze;Frank Dewater;Pete Janowitz;Dave Laib;Al Schamel;Bert tenKate;Ken Holland;Bill Mark;George Ermini;Dennis Braatz | ||
* [ | |manuals= | ||
* [ | '''465''' | ||
* [ | * [[Media:070-2038-00.pdf | 465 + DM44 Operator ]] (OCR, 4M)<br /><small>''[[Media:070-2038-00_1976.pdf | Alternate Copy ]]'' | ||
* [ | </small> | ||
* [[Media:070-2756- | * [[Media:070-1330-00.pdf | 465 Service, 070-1330-00 early version ]] (OCR, 53M)<br /><small>''[[Media:070-1330-00 (2).pdf | Alternate Copy ]] (OCR, 3M)<br />[[Media:TEK 465LOWSN 070-1330-00 REV1.pdf|465 Service, 070-1330-00 Low SN Rev.1]] (OCR, 27M)''</small> | ||
* [[Media:070-1861-00.pdf | 465 Service B250000+ ]] (OCR, 44M) | |||
* [[Media:070-1861-00_C.pdf | 465 Service B250000+ ]] (Color OCR, 58M) | |||
* [[Media:070-1861-01.pdf | 465 Service B250000 and up, later revision ]] | |||
* [[Media:070-1861-02.pdf | 465 Service B250000 and up, latest revision ]] | |||
* [[Media:070-2191-00.pdf | 465 Option 5 Supplement ]] | |||
'''465B''' | |||
* [[Media:070-2756-00.pdf | 465B + DM44 Operator -00, with Option 05 ]] (OCR) | |||
* [[Media:070-2756-01.pdf | 465B + DM44 Operator -01, with Option 05 ]] | |||
* [[Media:070-2757-00.pdf | 465B Service Manual ]] (200MB) | |||
* [[Media:070-4273-00.pdf | 465B Service Manual, B060000+ ]] | |||
* [[Media:465b_trig2.pdf | Tektronix 465B Trigger Generator Schematic ]] | |||
* [[Media:465b_schematic.pdf | Tektronix 465B Trigger Generator Schematic ]] (bad-OCR) | |||
* [[Media:465B_Vertical_Mode_Switch_(4)_Schematic.pdf | 465B Vertical Mode Switch Schematic <4> ]] | |||
<small> | |||
* [[Media:070-2757-00-M38666.jpg | Service Manual Change Information M38666 ]] | |||
* [[Media:070-2757-00-M40219.jpg | Service Manual Change Information M40219 ]] | |||
</small> | |||
<small> | <small> | ||
'''Modifications''' | '''Modifications''' | ||
* [ | * [https://hakanh.com/dl/docs/kitinstructions/040-0968-01.pdf 040-0968-01 ]: 465 Opt.7 External DC Operation (1982) | ||
* [ | * [https://hakanh.com/dl/docs/kitinstructions/040-0814-02.pdf 040-0814-02 ]: Installation of [[DM44]] on 465 B052300 - B251074 | ||
* [ | * [https://hakanh.com/dl/docs/kitinstructions/040-0815-01.pdf 040-0815-01 ]: Installation of [[DM44]] on 465 B251075 & up | ||
* [ | * [https://hakanh.com/dl/docs/kitinstructions/040-0944-00.pdf 040-0944-00 ]: Installation of [[DM44]] on 465B | ||
* [ | * [https://hakanh.com/dl/docs/kitinstructions/050-1627-00.pdf 050-1627-00 ]: S1150 (Time/cm switch) replacement | ||
* [[Media:061-1904-00.pdf | 465 DIGITAL STORAGE Mod UC ]] | |||
* [[Media:061-1057-00.pdf | 465 Mod XB ]] | |||
* [[Media:050-1558-00.pdf | 465B Modification: U3165 Replacement ]] | |||
* [[050-0674-00 | Handle Replacement Modification Kit ]] | |||
* [[Media:Tek 465 mod QB transition counter.pdf | 465 Mod QB Transition Counter ]] | |||
</small> | </small> | ||
====History==== | |||
* [[Media:Tek 465 and 475 marketing sales release.pdf | Tektronix 465 and 475 Marketing Sales Release ]] | |||
}} | }} | ||
:''Note: The [[465M|Tektronix 465M scope]] has its own page.'' | |||
The '''Tektronix 465''' is a portable 100 MHz dual-trace oscilloscope with dual time-bases. | The '''Tektronix 465''' is a portable 100 MHz dual-trace oscilloscope with dual time-bases, [[introduced in 1972|introduced in November 1972]]. | ||
The 465 was very popular and Tek made them for quite a few years. | It is all solid-state except for the CRT. The 465 was very popular and Tek made them for quite a few years. According to microfiche records, 37 variations of the 465 were produced. | ||
[[Bill Turner|There was no 465A]] but a 465B (int. 1980) with the same base specs but improved performance. | [[Bill Turner|There was no 465A]] but a 465B (int. 1980) with the same base specs but improved performance. | ||
The [[475]] is a 200 MHz sister model. | The [[475]] is a 200 MHz sister model. See also [[465M]]. | ||
The optional [[DM44]] multimeter attaches to the top of the instrument. | The optional [[DM44]] multimeter attaches to the top of the instrument. | ||
== | From [[Media:Tekscope 1972 V4 N5 Sep 1972.pdf | Tekscope Vol. 4 No. 5, 1972 ]]: | ||
[[ | <blockquote> | ||
Initial product planning and project coordination was provided by [[Leon Orchard]]. | |||
The mechanical design team for the 465 and 475, headed by [[Bob Rossman]], was: [[Neal Broadbent]], [[Bob Leith]], [[Len McCracken]], [[Bob Smesrud]], [[Ilmars Smiltins]], and [[Bob Twigg]]. | |||
[[Ken Holland]] and [[Bill Mark]] provided the attenuator design while [[Bob Johnson]] designed the [[P6065]] and [[P6075]] probes. Low-voltage power supply for the 465/475 was by [[George Ermini]], and [[Dennis Braatz]] designed the high-voltage supply. [[Connie Wilson]] and [[Gary Nelson]] did the CRT development. | |||
Electrical design team assisting [[R. Michael Johnson]] in development of the 465 was: [[Frank Dewater]], [[Pete Janowitz]], [[Dave Laib]], [[Al Schamel]], and [[Bert tenKate]]. | |||
</blockquote> | |||
[[Bill Turner]] worked as a calibration technician for the 465 oscilloscope group. | |||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C }} | |||
{{Spec | Risetime | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C }} | |||
{{Spec | Input impedance | 1 MΩ ±2% // 20 pF }} | |||
{{Spec | Input voltage | max. 500 V DC (250 V<sub>DC</sub> when DC coupled) + Peak AC or 500 V<sub>p-p</sub> AC at < 1 kHz }} | |||
{{Spec | Trigger coupling | DC, AC, LF Reject, HF Reject }} | |||
{{Spec | Channel isolation | 100:1 at 25 MHz }} | |||
{{Spec | Z-Axis input | DC to 50 MHz; 5 V<sub>p-p</sub> signal causes noticeable modulation at normal intensity }} | |||
{{Spec | Output signals | CH1 Vertical, A & B +Gate }} | |||
{{Spec | Calibrator | ~1 kHz, 300 mV, square wave }} | |||
{{Spec | CRT | [[T4650]] ([[154-0676-00]]/[[154-0676-05]]/[[154-0676-10]]) tube, P31 [[phosphor]], 18.5 kV acceleration, 8 cm × 10 cm graticule }} | |||
{{Spec | Power | 110/115/120/220/230/240 V<sub>AC</sub> ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz; 75 W }} | |||
{{EndSpecs}} | |||
==Options== | |||
<small> | |||
{| class="wikitable" | |||
|+ 465 Options | |||
|- | |||
! Opt !! Tek catalogue name !! Description | |||
|- | |||
| 4 || EMI Environmental || Adds filter circuits and Faraday mesh+ground contact spring in place of acrylic implosion window. | |||
|- | |||
| 5 || TV Sync Separator || This option has a separate service manual. | |||
|- | |||
| 7 || EXT DC Operation || DC Power Input. Adds rear socket, power selector switches and inverter module. Not available with DM43 or DM40. | |||
|- | |||
| 78 || P11 Phosphor || Replaces P31 phosphor 154-0676-10 with P11 version 154-0676-14. | |||
|} | |||
</small> | |||
==Links== | |||
* [https://lazyelectrons.wordpress.com/2017/10/30/tektronix-465-repair/ Rajesh's Tek 465 Repair ] | |||
* [https://www.youtube.com/watch?v=I6ODi7qSpYg Jim Williams repairs Tom Osborne's Tektronix 465B oscilloscope] (YouTube) | |||
* [https://www.youtube.com/watch?v=81UA49dOFa4 Another successful 465 repair, shorted tantalum] (YouTube) | |||
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/465.htm Tek 465 page @ amplifier.cd] | |||
* [http://lists.contesting.com/_amps/2012-06/msg00415.html 465B differences ] | |||
* [http://dangerousprototypes.com/2012/03/19/tektronix-465-oscilloscope-teardown/ Tek 465 "teardown" ] | |||
* [https://groups.io/g/TekScopes/files/Replacing%20Electrolytic%20Filter%20Capacitors%20in%20a%20Tektronix%20465.pdf Replacing Electrolytic Filter Capacitors in a Tektronix 465] | |||
* [https://www.youtube.com/watch?v=cnoWBIZUKHg Power Supply and Tube Calibration] by Zenwizard Studios @ YouTube | |||
* [https://www.youtube.com/watch?v=icGTBV1ZcUU Vertical Amplifier Calibration (Full)] by Zenwizard Studios @ YouTube | |||
* [https://www.youtube.com/watch?v=0g4dvpv3RBI Trigger and Timebase Calibration (Full)] by Zenwizard Studios @ YouTube | |||
* [https://www.youtube.com/watch?v=XqiMlfYoNP8 Extensive Board Removal (All but Main board)] by Zenwizard Studios @ YouTube | |||
* [https://www.youtube.com/watch?v=AydDpgdCrFU 465 Mod UC ] by vintageTek Museum @ YouTube | |||
* [https://www.youtube.com/watch?v=xe0uofu9lTc Tektronix 465 Repair (Horz sweep Issues)] by Zenwizard Studios @ YouTube | |||
{{Documents|Link=465}} | |||
{{Documents|Link=465B}} | |||
{{PatentLinks|465}} | |||
==Prices== | |||
{| class="wikitable" | |||
|- | |||
! Year | |||
! 1973 | |||
! 1976 | |||
! 1980 (B) | |||
! 1982 (B) | |||
! 1983 | |||
|- | |||
! Catalog Price | |||
| $1,725 | |||
| $2,095 | |||
| $2,600 | |||
| $2,995 | |||
| | |||
|- | |||
! In 2023 Dollars | |||
| $12,000 | |||
| $11,300 | |||
| $9,700 | |||
| $9,600 | |||
| | |||
|} | |||
==Internals== | ==Internals== | ||
The 465 uses tunnel diodes with Tek part number 152-0125-00, | The 465 uses tunnel diodes with Tek part number [[152-0125-00]], which are equivalent to [[TD3A]], and [[155-0032-00]] chips (their -01 grade) as trigger amplifiers. | ||
which are equivalent to [[TD3A]], and [[155-0032-00]] chips (their -01 grade) as trigger amplifiers | |||
== | ==Common Problems== | ||
* [ | * See [[465/Repairs]] | ||
==Pictures== | ==Pictures== | ||
===465=== | |||
<gallery> | <gallery> | ||
Tek-465-front.jpg | |||
Tek-465-back.jpg | |||
Tek 465 trace.jpg | Tek 465 trace.jpg | ||
Tek 465 front2.jpg | Tek 465 front2.jpg | ||
Tek 465 front right.jpg | Tek 465 front right.jpg | ||
Tek-465-int1.jpg | |||
Tek-465-int2.jpg | |||
Tek-465-int3.jpg | |||
Tek-465-int4.jpg | |||
</gallery> | |||
===465 OPT 4=== | |||
<gallery> | |||
465_clear_vs_EMI_mesh.jpg | |||
</gallery> | |||
===465 OPT 7=== | |||
<gallery> | |||
465-opt-7_20220807.jpg | |||
</gallery> | </gallery> | ||
===465 Mod UC=== | |||
<gallery> | |||
Tek 465 mod uc front.jpg | |||
Tek 465 mod uc internal.jpg | |||
</gallery> | |||
===465B=== | |||
<gallery> | |||
Tek 465b trace.jpg | |||
Tek 465b front.jpg | |||
Tek 465b g1.jpg | |||
Tek 465b g2.jpg | |||
Tek 465b g3.jpg | |||
Tek 465b g4.jpg | |||
Tek 465b g6.jpg | |||
Tek 465b g7.jpg | |||
465B Interface Board 670-5996-13.jpg |Interface board | |||
465B Interface Board 670-5996-13 flash.jpg |(camera flash used) | |||
</gallery> | |||
==Components== | |||
{{Parts|465}} | |||
{{Parts|465B}} | |||
[[Category:400 series scopes]] | [[Category:400 series scopes]] | ||
Latest revision as of 05:08, 25 June 2024
- Note: The Tektronix 465M scope has its own page.
The Tektronix 465 is a portable 100 MHz dual-trace oscilloscope with dual time-bases, introduced in November 1972. It is all solid-state except for the CRT. The 465 was very popular and Tek made them for quite a few years. According to microfiche records, 37 variations of the 465 were produced.
There was no 465A but a 465B (int. 1980) with the same base specs but improved performance. The 475 is a 200 MHz sister model. See also 465M.
The optional DM44 multimeter attaches to the top of the instrument.
From Tekscope Vol. 4 No. 5, 1972 :
Initial product planning and project coordination was provided by Leon Orchard. The mechanical design team for the 465 and 475, headed by Bob Rossman, was: Neal Broadbent, Bob Leith, Len McCracken, Bob Smesrud, Ilmars Smiltins, and Bob Twigg. Ken Holland and Bill Mark provided the attenuator design while Bob Johnson designed the P6065 and P6075 probes. Low-voltage power supply for the 465/475 was by George Ermini, and Dennis Braatz designed the high-voltage supply. Connie Wilson and Gary Nelson did the CRT development.
Electrical design team assisting R. Michael Johnson in development of the 465 was: Frank Dewater, Pete Janowitz, Dave Laib, Al Schamel, and Bert tenKate.
Bill Turner worked as a calibration technician for the 465 oscilloscope group.
Key Specifications
Bandwidth | DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C |
---|---|
Risetime | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C |
Input impedance | 1 MΩ ±2% // 20 pF |
Input voltage | max. 500 V DC (250 VDC when DC coupled) + Peak AC or 500 Vp-p AC at < 1 kHz |
Trigger coupling | DC, AC, LF Reject, HF Reject |
Channel isolation | 100:1 at 25 MHz |
Z-Axis input | DC to 50 MHz; 5 Vp-p signal causes noticeable modulation at normal intensity |
Output signals | CH1 Vertical, A & B +Gate |
Calibrator | ~1 kHz, 300 mV, square wave |
CRT | T4650 (154-0676-00/154-0676-05/154-0676-10) tube, P31 phosphor, 18.5 kV acceleration, 8 cm × 10 cm graticule |
Power | 110/115/120/220/230/240 VAC ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz; 75 W |
Options
Opt | Tek catalogue name | Description |
---|---|---|
4 | EMI Environmental | Adds filter circuits and Faraday mesh+ground contact spring in place of acrylic implosion window. |
5 | TV Sync Separator | This option has a separate service manual. |
7 | EXT DC Operation | DC Power Input. Adds rear socket, power selector switches and inverter module. Not available with DM43 or DM40. |
78 | P11 Phosphor | Replaces P31 phosphor 154-0676-10 with P11 version 154-0676-14. |
Links
- Rajesh's Tek 465 Repair
- Jim Williams repairs Tom Osborne's Tektronix 465B oscilloscope (YouTube)
- Another successful 465 repair, shorted tantalum (YouTube)
- Tek 465 page @ amplifier.cd
- 465B differences
- Tek 465 "teardown"
- Replacing Electrolytic Filter Capacitors in a Tektronix 465
- Power Supply and Tube Calibration by Zenwizard Studios @ YouTube
- Vertical Amplifier Calibration (Full) by Zenwizard Studios @ YouTube
- Trigger and Timebase Calibration (Full) by Zenwizard Studios @ YouTube
- Extensive Board Removal (All but Main board) by Zenwizard Studios @ YouTube
- 465 Mod UC by vintageTek Museum @ YouTube
- Tektronix 465 Repair (Horz sweep Issues) by Zenwizard Studios @ YouTube
Documents Referencing 465
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1972 V4 N5 Sep 1972.pdf | Article | The New Look in Portables | 1972 | 465 • 475 | |
Tekscope 1974 V6 N1.pdf | Article | Servicing the 465 Portable Oscilloscope | 1974 | 465 | |
Tekscope 1974 V6 N4.pdf | Article | The Oscilloscope with the Digital Multimeter | Dennis Bratz | 1974 | DM43 • 465 |
Tekscope 1975 V7 N3.pdf | Article | A Potpourri of Modifications and Service Hints | 1975 | 465 • 5L4N • 464 • 466 • 575 • 576 • 577 • TM504 |
Documents Referencing 465B
Document | Class | Title | Authors | Year | Links |
---|---|---|---|---|---|
Tekscope 1979 V11 N2.pdf | Article | Updating the Industry-Standard 100 MHz Portable Oscilloscope | Harold Busch | 1979 | 465B |
Patents that may apply to 465
Page | Title | Inventors | Filing date | Grant date | Links |
---|---|---|---|---|---|
Patent US 3562464A | Cam actuated switch having movable and fixed contacts on circuit board | Howard Vollum • Willem H Verhoef • Tony Sprando | 1968-10-07 | 1971-02-09 | Cam switches • 2101 • 2701 • 2703 • 432 • 434 • 465 • 475 • 5A15N • 5A18N • 5A20N • 5A21N • 5A38 • 5A45 • 5B10N • 5B12N • 7A15 • 7A16A • 7A18 • 7A19 • 7A24 • 7A26 • 7B10 • 7B15 • 7B50 • 7B51 • 7B52 • 7B53A • 7B50A • 7B70 • 7B71 • 7B80 • 7B85 • 7B87 • 7B92 • 7B92A • 7D01 • 7D12 • 7D15 • 7J20 • 7S12 • 7T11 • 7T11A • AF501 • AM502 • AM503 • DC502 • DC503 • DC504 • DC505 • DM501 • DM502 • FG501 • FG501A • FG502 • FG503 • FG504 • FG507 • PG501 • PG502 • PG505 • PG506 • PG506A • PG508 • TG501 • SC502 • SC503 • SC504 |
Patent US 3725724A | Deflection factor indicating apparatus | Howard Vollum | 1971-01-11 | 1973-04-03 | 464 • 465 • 475 • 5A14N • 5A26N • 5A48 |
Patent US 3719788A | Switch having ganged contacts mounted on opposite sides of circuit board | Ken Holland • Tony Sprando | 1971-02-04 | 1973-03-06 | 465 • 475 • 5A38 • 5A45 • 7A15 • 7A16A • 7A18 • 7A19 • 7A24 • 7A26 • 7D15 • PG506 |
Patent US 3753170A | Step attenuator apparatus having attenuator stages selectively connected in cascade by cam actuated switches | Ken Holland | 1971-02-10 | 1973-08-14 | 465 • 475 • 5A38 • 5A45 • 7A15 • 7A16A • 7A18 • 7A19 • 7A24 • 7A26 |
Patent US 3900711A | Electrical contactor assembly for high frequency applications | Ken Holland | 1974-02-04 | 1975-08-19 | 465 • 475 • 5A38 • 5A45 • 7A15 • 7A16A • 7A18 • 7A19 • 7A24 • 7A26 • 7D15 • AM503 |
Prices
Year | 1973 | 1976 | 1980 (B) | 1982 (B) | 1983 |
---|---|---|---|---|---|
Catalog Price | $1,725 | $2,095 | $2,600 | $2,995 | |
In 2023 Dollars | $12,000 | $11,300 | $9,700 | $9,600 |
Internals
The 465 uses tunnel diodes with Tek part number 152-0125-00, which are equivalent to TD3A, and 155-0032-00 chips (their -01 grade) as trigger amplifiers.
Common Problems
- See 465/Repairs
Pictures
465
465 OPT 4
465 OPT 7
465 Mod UC
465B
-
-
-
-
-
-
-
-
-
Interface board
-
(camera flash used)
Components
Some Parts Used in the 465
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0731-00 | 154-0731-00 • 154-0731-01 • 154-0731-02 • 154-0731-04 | CRT | CRT | Telequipment D75 • 455 • 465 • 465B • 468 |
155-0032-00 | 155-0032-00 • 155-0032-01 | Monolithic integrated circuit | variable-gain transconductance amplifier (voltage in, current out) | 335 • 464 • 465 • 465B • 466 • 475 • 475A • 475M • 634 • 650 • 651 • 652 • 653 • 655 • 656 • 670 • 671 • 7A12 • 475 • FG504 • 1440 • 1460 • 1480 • 1481 • 1482 • 1485 |
155-0049-00 | 155-0049-00 • 155-0049-01 • 155-0049-02 | Monolithic integrated circuit | sweep control with lockout | 335 • 464 • 465 • 466 • 475 • 475A • 475M • 485 • 5B31 • 5B40 • 5B52 • 5B42 • 5B44 • 7B53A • 7B80 • 7B85 • 7B87 • 7B92A • 7B90P • 7B10 • 7B15 • SC502 • 7B42N • AN/USM-281C • 067-0657-00 |
155-0076-00 | 155-0076-00 | Monolithic integrated circuit | input protection and probe logic | 465 • 485 • 7A29 • 7A29P • 11A52 • 11A71 • 11A72 • SCD1000 |
155-0077-00 | 155-0077-00 • 155-0077-01 | Hybrid integrated circuit | vertical output amplifier | 335 • 464 • 465 • 466 • 7704A |
155-0078-00 | 155-0078-xx • 155-0273-00 • 155-0274-00 | Monolithic integrated circuit | broadband amplifier | 464 • 465 • 466 • 468 • 475 • 475A • 475M • 485 • 7834 • 7844 • 7854 • 7904 • R7903 • R7912 • 7912AD • 7912HB • 7104 • 7A16A • 7A16P • 7A24 • 7A26 • 7A42 • 067-0587-01 • 067-0680-00 • AM503 • PG502 • PG508 • DC510 • DC5010 • FG5010 |
155-0115-00 | 155-0115-00 | Hybrid integrated circuit | vertical amplifier | 335 • 464 • 465 • 465B • 466 • 468 |
SKA6516 | 151-0367-00 | Discrete component | NPN Transistor | 465 • 465B • 466 • 475 |
STD704 | 152-0125-00 | Discrete component | 4.7 mA tunnel diode | 1L40 • 1S1 • 11B1 • 11B2 • 11B2A • 147 • R147 • 147A • R147A • 1470 • 148 • R148 • 148-M • 149 • R149 • 149A • R149A • 21A • 22A • 3B4 • 3B5 • 408 • 432 • 434 • 453 • 453A • 454 • 464 • 465 • 466 • 491 • 5T3 • 544 • RM544 • 546 • RM546 • 547 • RM547 • 556 • RM556 • 7B70 • 7B71 • 7D11 |
T4650 | 154-0676-00 • 154-0676-05 • 154-0676-10 • 154-0676-14 | CRT | CRT | 465 • Telequipment D75 • Telequipment D755 |
Some Parts Used in the 465B
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
154-0731-00 | 154-0731-00 • 154-0731-01 • 154-0731-02 • 154-0731-04 | CRT | CRT | Telequipment D75 • 455 • 465 • 465B • 468 |
155-0032-00 | 155-0032-00 • 155-0032-01 | Monolithic integrated circuit | variable-gain transconductance amplifier (voltage in, current out) | 335 • 464 • 465 • 465B • 466 • 475 • 475A • 475M • 634 • 650 • 651 • 652 • 653 • 655 • 656 • 670 • 671 • 7A12 • 475 • FG504 • 1440 • 1460 • 1480 • 1481 • 1482 • 1485 |
155-0115-00 | 155-0115-00 | Hybrid integrated circuit | vertical amplifier | 335 • 464 • 465 • 465B • 466 • 468 |
SKA6516 | 151-0367-00 | Discrete component | NPN Transistor | 465 • 465B • 466 • 475 |